ABB SB171 3BSE004802R1 is a backup power supply designed to charge a 12 V, 4 Ah NiCd battery in supported ABB control systems.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for SB171 3BSE004802R1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for SB171 3BSE004802R1

  • Manufacturer:
    ABB
  • Part Number:
    SB171 3BSE004802R1
  • Product Family:
    ABB Advant OCS and Advant-800xA
  • Product Type:
    Backup Power Supply
  • Stock:
    1
  • Type designation:
    SB171
  • Product ID:
    3BSE004802R1
  • Battery chemistry:
    NiCd
  • Battery rating:
    12 V, 4 Ah
  • ABB lifecycle:
    Active; available on request
  • Weight:
    0.315 kg
  • Estimated shipping dimensions:
    23.4x9x5.4cm
  • Tariff Code:
    850440
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Battery Duty System Placement Supply Planning Product Applications

Features:

  • Battery duty: designed for a 12 V, 4 Ah NiCd battery.
  • ABB system scope: classified for AC400, AC410, MOD 300, and Safeguard 400 contexts.
  • Official status: ABB lists the material as Active and supplied on request.
SB171 3BSE004802R1 provides the charging function for a defined backup-battery arrangement in supported ABB control systems.

The product identity combines the type designation SB171 with ABB material number 3BSE004802R1, and both should be retained in procurement records.

Battery chemistry and capacity are selection boundaries, not interchangeable descriptive values.

Apter Power supports document review, quotation, and procurement for the ABB SB171 3BSE004802R1 Backup Power Supply.
ABB SB171 3BSE004802R1 Backup Power Supply Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Chemistry: the official application is a nickel-cadmium battery.
  • Nominal voltage: the documented battery is rated 12 V.
  • Capacity: the specified battery capacity is 4 Ah.
  • AC400 and AC410: ABB includes the supply in relevant accessory classifications.
  • MOD 300: the product is classified for AC410-based MOD 300 installations.
  • Safeguard 400: ABB lists the product within the supported system scope.
  • Exact identity: retain both SB171 and 3BSE004802R1.
  • On-request supply: confirm availability and replacement guidance at quotation.
  • Battery evidence: record chemistry, voltage, capacity, and wiring before ordering.
  • AC400 and AC410: backup-battery charging within the documented control-system design.
  • MOD 300: support for AC410-based control installations using the specified battery.
  • Safeguard 400: charger replacement where the exact ABB material is installed.
Description
The SB171 3BSE004802R1 is an ABB backup power supply designed to charge the documented 12 V, 4 Ah nickel-cadmium battery arrangement in supported AC400, AC410, MOD 300, and Safeguard 400 installations.

Maintaining the specified battery chemistry and capacity allows SB171 3BSE004802R1 to preserve the intended charging behavior and backup function instead of exposing the cabinet to an unsupported battery profile.

Replacement work for SB171 3BSE004802R1 should retain the complete ABB material number and reconcile battery polarity, protective devices, wiring, and cabinet role before energizing. This reduces the risk of reverse connection, charging faults, or loss of backup autonomy.
Alternative Names
SB171 3BSE004802R1
Technical notes
Use SB171 3BSE004802R1 only with the documented 12 V, 4 Ah NiCd battery arrangement. Verify battery chemistry, polarity, cable protection, cabinet ventilation, and the supported control-system drawing; stop commissioning if the installed battery specification or charger wiring differs from the approved record, and document the final charging test.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should SB171 3BSE004802R1 be selected when the installed battery label is unreadable?
Do not order until the cabinet drawing or maintenance record confirms a 12 V, 4 Ah NiCd arrangement, the wiring polarity, and the exact ABB material number.
Can SB171 3BSE004802R1 be used with a different 12 V battery chemistry?
No interchangeability should be assumed. Its documented duty is the 12 V, 4 Ah NiCd arrangement, so another chemistry requires an approved charging design.
Which installation checks protect SB171 3BSE004802R1 from a reversed battery connection?
Verify isolation, polarity, fuse protection, conductor identification, and the approved battery label before energizing. Stop immediately if voltage or chemistry differs.
If SB171 3BSE004802R1 does not maintain the backup function, what should be diagnosed first?
Check battery condition, the charging path, protective devices, wiring continuity, and cabinet alarms before replacing the supply again.
What must a modernization preserve when replacing the charger function of SB171 3BSE004802R1?
Preserve the required autonomy, battery technology, charger supervision, cabinet constraints, and failure response, then test the approved arrangement before removing the original supply.
How should technicians verify SB171 3BSE004802R1 after battery service?
Confirm correct polarity and charging behavior, prove the alarm response, run the required backup-duration test, and verify the cabinet returns to normal operation.