Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power aligns firmware and gateway-license evidence with network scope and controller condition before sourcing.

P-HC-BRC-41000000

/ 4.9
1001 reviews | Need a Specific Revision?
Ethernet-based Modbus TCP device integration distinguishes ABB P-HC-BRC-41000000 within the Harmony Rack bridge-controller family.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for P-HC-BRC-41000000
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for P-HC-BRC-41000000

  • Manufacturer:
    ABB
  • Part Number:
    P-HC-BRC-41000000
  • Product Family:
    ABB Bailey
  • Product Type:
    Bridge Controller with Ethernet
  • Stock:
    1
  • Processor:
    160 MHz, 32-bit Freescale ColdFire
  • Control library:
    More than 150 function codes
  • User configuration memory:
    2 MB NVRAM
  • Function block capacity:
    30,000
  • Online configuration:
    Flexible capability
  • Supported I/O:
    HR Series, SD Series, and S800 I/O
  • Ethernet role:
    100 Mb Modbus TCP device integration
  • Firmware:
    Downloadable
  • Weight:
    0.32 kg
  • Estimated shipping dimensions:
    3.5 x 32 x 17.5 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Modbus TCP Toolchain Network Review

Features:

  • Ethernet integration: this exact variant adds the documented 100 Mb Modbus TCP path.
  • Extended control capacity: 2 MB NVRAM supports up to 30,000 function blocks.
  • Mixed I/O reach: HR Series, SD Series, and S800 I/O are supported simultaneously.
P-HC-BRC-41000000 adds an Ethernet device-integration role to the common HR Series controller platform.

Its expanded configuration memory and online-change capability suit control strategies that exceed the lower-capacity baseline while retaining rack and remote I/O paths.

Gateway licensing, tool compatibility, firmware, and network security must be resolved before Modbus TCP points are commissioned.

Availability of P-HC-BRC-41000000 is subject to Apter Power's current inventory and sourcing confirmation.
P-HC-BRC-41000000 Bridge Controller with Ethernet Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
P-HC-BRC-41000000 Bridge Controller with Ethernet Specs

General

  • ManufacturerABB
  • ModelP-HC-BRC-41000000
  • ConditionNew Original ready stock
  • Product FamilyHarmony Rack Controllers
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Ethernet device integration

  • Ethernet boundary: ABB assigns Modbus TCP support to this controller variant.
  • Point scope: reconcile licensed tags with the approved gateway database.
  • Server/client roles: document every peer and data direction.
  • Failure response: test stale-data and network-loss behavior before handover.

Engineering compatibility

  • Controller firmware: compare the installed revision with ABB gateway requirements.
  • Composer level: use the version required by the approved Harmony Gateway release.
  • Project conversion: protect converted databases and retain the source copy.
  • Rollback: keep a tested controller and gateway recovery package.

Controlled Ethernet deployment

  • Address plan: reserve controller, gateway, server, and client addresses.
  • Segmentation: apply the site control-network security architecture.
  • Switch path: document ports, redundancy, and link supervision.
  • Acceptance: prove values, timestamps, quality, and recovery after interruption.
Description
Networked control projects use P-HC-BRC-41000000 as a Harmony Rack bridge controller with a 100 Mb Ethernet path for Modbus TCP device integration in addition to established rack control responsibilities.

A 160 MHz 32-bit ColdFire platform, more than 150 function codes, extended 2 MB NVRAM, support for 30,000 function blocks, and flexible online configuration define the control capacity documented for P-HC-BRC-41000000.

Before introducing P-HC-BRC-41000000, the controller firmware, Composer or Harmony Gateway tool level, Ethernet addressing, Modbus server/client design, licensed point count, I/O paths, and tested configuration backup must be treated as one controlled change.
Alternative Names
ABB P-HC-BRC-41000000 PHCBRC41000000 P HC BRC 41000000 P-HC BRC 41000000 ABB Bailey BRC410 Ethernet controller Harmony Rack BRC410 bridge controller
Technical notes
Modbus TCP commissioning is the main boundary for P-HC-BRC-41000000. ABB’s Harmony Gateway 6.0 notes require the correct controller firmware and compatible Composer environment; preserve the licensed point scope, address map, server/client roles, and rollback-ready controller configuration before enabling Ethernet traffic on the live control network.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Local rack control continues but Modbus values from P-HC-BRC-41000000 become stale; which evidence separates logic from network failure?
Correlate controller and gateway diagnostics with link state, session status, point quality, address mapping, and the configured stale-data response.
After a gateway software change, what should be compared before P-HC-BRC-41000000 resumes Ethernet data exchange?
Compare controller firmware, engineering-tool release, converted project identity, licensed point scope, and the tested rollback package with the approved baseline.
How can the configured failure response of P-HC-BRC-41000000 be tested without treating one live network interruption as sufficient evidence?
Use a controlled outage test that records value quality, data direction, application behavior, recovery time, and rollback criteria for each approved connection.
A Modbus address map imports successfully but P-HC-BRC-41000000 shows incorrect values; where should diagnosis begin?
Check server/client ownership, data direction, register mapping, scaling, point quality, and the approved database revision before changing controller logic.
Which records should be retained when expanding the licensed point scope around P-HC-BRC-41000000?
Keep the prior and revised licenses, approved point count, address map, gateway database, controller backup, test results, and rollback decision.
What makes a sourcing package for P-HC-BRC-41000000 useful to both control and network teams?
Include the exact order code, firmware, redundancy design, I/O families, gateway release, licensed scope, Ethernet architecture, and outage window.
When a switch port is moved, how should P-HC-BRC-41000000 recovery be accepted before closing the outage?
Verify link supervision, sessions, point quality, timestamps, both data directions, interruption recovery, and unaffected rack-control behavior against the test plan.