SPNPM22

/ 4.9
1001 reviews | Need a Specific Revision?
ABB SPNPM22 is a Symphony Plus Harmony Rack network processing module for the control-unit communication path. It maintains the unit database and directs messages between Controlway resources and the Cnet interface.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for SPNPM22
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for SPNPM22

  • Manufacturer:
    ABB
  • Part Number:
    SPNPM22
  • Product Family:
    ABB Bailey
  • Product Type:
    network processing module
  • Stock:
    1
  • Gateway path:
    Cnet to Controlway
  • Database role:
    Harmony control-unit database storage
  • Companion interface:
    Cnet network interface module
  • Controlway rate:
    1 Mbaud
  • Modulebus rate:
    83.3 kbaud
  • Diagnostic interface:
    Mini-USB
  • DRAM:
    8 MB
  • NVRAM:
    512 KB
  • Flash ROM:
    2 MB
  • Supply voltage:
    +5 VDC
  • Typical supply current:
    2 A
  • Typical power:
    10 W
  • Ambient temperature:
    0-70 °C
  • Weight:
    0.6173 lbs (0.28 kg)
  • Estimated shipping dimensions:
    3.6 x 32.5 x 17.7 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Communication & Connectivity Firmware Interoperability

Features:

  • Provides the Cnet-to-Controlway gateway function.
  • Stores the HCU database.
  • Works with the SPNIS21 network interface module.

The current ordering configuration is SPNPM22, the ABB network processing module installed as the gateway between Cnet and Controlway.

It holds the Harmony control unit database and directs communication between Controlway modules and the SPNIS21 network interface.

For SPNPM22, confirm the exact companion hardware, network mode, addresses, firmware and termination before installation.

Availability is subject to Apter Power inventory and sourcing confirmation.

Verified resources for ABB SPNPM22:

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

ABB SPNPM22 General Specifications

General

  • ManufacturerABB
  • ModelSPNPM22
  • ConditionNew / Surplus / Refurbished
  • Product FamilySymphony Plus Harmony Rack
  • The module directs communication between the Cnet side and Controlway resources in the control unit.
  • Controlway or Modulebus operation follows the communication architecture selected for the installed rack.
  • The diagnostic connection supports service access without changing the normal process-network path.
  • Volatile and nonvolatile memory retain runtime data, configuration records and module firmware.
  • Rack power and cabinet conditions must support the network processor together with its companion hardware.
  • Back up the control-unit database and addressing information before exchanging the module.
  • The documented Cnet interface module completes the network side of the communication node.
  • Companion modules must use aligned addresses, firmware and communication-mode settings.
  • Verify the whole Harmony control-unit arrangement before replacing either side of the interface.
Description
SPNPM22 is the ABB Harmony Rack network processing module that forms the gateway between Cnet and the Controlway side of a configured control unit.

It maintains the control-unit database and directs messages between rack modules and the companion network interface for coordinated system communication.

Replacement planning must preserve the interface pairing, communication mode, node addresses, firmware, termination and current database backup.
Alternative Names
SPNPM22 ABB SPNPM22 SPNPM22 network processing module Symphony Plus Harmony Rack SPNPM22 ABB Symphony Plus Harmony Rack SPNPM22 ABB Symphony Plus Harmony Rack network processing module
Technical notes
Before energizing SPNPM22, verify field wiring, power isolation and the validated Symphony Plus Harmony Rack configuration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which communication settings should be captured before exchanging SPNPM22?
Capture the Controlway or Modulebus mode, node addresses, companion interface, firmware, termination and current control-unit database.
Which Cnet interface operates with SPNPM22?
SPNPM22 operates with the documented Cnet interface module on the documented Harmony control-unit communication path.
What database and gateway duties are assigned to SPNPM22?
It holds the Harmony control-unit database and directs messages between Controlway modules and the network interface.
How should the HCU arrangement be described when requesting SPNPM22 availability?
List the companion interface, communication mode, addresses, firmware, quantity and required delivery date for Apter Power sourcing.
What settings should be recorded before replacing SPNPM22?
Record module addresses, Controlway or Modulebus mode, firmware, termination and the complete HCU companion-module arrangement.
Which RFQ details should be checked against the SPNPM22 Datasheet?
Use the PDF in Manuals and submit the exact module, companion interface, firmware, network mode, quantity and ship-to destination.