Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB records, R2 migration checks, and braking review.

ACS510-01-017A-4

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS510-01-017A-4 is a 7.5 kW, 17 A, 380-480 V IP21 general purpose drive built in the ACS510 R2 frame.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS510-01-017A-4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS510-01-017A-4

  • Manufacturer:
    ABB
  • Part Number:
    ACS510-01-017A-4
  • Product Family:
    ABB Drives
  • Product Type:
    ACS510 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3ABD00015747-D
  • Input Voltage:
    380 ... 480 V AC
  • Input Frequency:
    47.5 ... 63 Hz
  • Number of Phases:
    3-phase
  • Normal Output Current:
    17 A
  • Normal Output Power:
    7.5 kW
  • Apparent Power Output:
    12 kV·A
  • Frame Size:
    R2
  • Degree of Protection:
    IP21
  • Enclosure Type:
    NEMA Type 1
  • Mounting:
    Wall-mounted
  • Efficiency Level:
    IE2
  • Standby Loss:
    12 W
  • Temperature Rating:
    40 °C
  • Built-in Communication:
    Modbus
  • Weight:
    8.8 kg
  • Estimated shipping dimensions:
    22.5 x 36.5 x 56.5 cm
  • Tariff Code:
    85044099
  • Country of origin:
    China
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications R2 Migration Braking Plan Maintenance

Features:

  • 7.5 kW output rating at 17 A
  • R2 IP21 wall-mounted frame
  • Internal brake chopper with built-in Modbus interface
ACS510-01-017A-4 is the 17 A R2 configuration for 7.5 kW motor duties.

The larger frame changes the mechanical and cable-entry requirements while the ACS510 platform continues to support local, hardwired, and Modbus-based process control.

A sound project compares motor and load data, R2 space and airflow, braking energy, feeder protection, signal logic, firmware and parameter records, and maintenance access.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS510-01-017A-4 ACS510 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS510-01-017A-4 ACS510 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS510-01-017A-4
  • ConditionNew Original ready stock
  • Product FamilyABB ACS510 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Mechanical transition review

  • Footprint: Compare exact R2 mounting dimensions and fastener positions with the existing panel.
  • Depth: Check cover, cable-bend, door, and service clearances before fabrication.
  • Terminals: Verify conductor range, entry direction, lug preparation, and torque instructions.
  • Cooling: Keep the R2 air path unobstructed and account for enclosure heat.

Stopping-duty preparation

  • Energy: Calculate regenerative energy from inertia, speed, stopping time, and repetition.
  • Resistor: Select only an approved resistor within the internal chopper limits.
  • Protection: Provide the specified thermal and fault response for the braking circuit.
  • Process safety: Do not use dynamic braking as a substitute for the required safe stopping method.

R2 service readiness

  • Backups: Store accepted parameters, motor data, I/O, and Modbus configuration.
  • Inspection: Plan checks for fan, airflow, terminals, contamination, and cable condition.
  • Fault capture: Preserve event details and process state before clearing recurrent trips.
  • Replacement: Compare Product ID, frame, options, terminals, and drawings before exchange.
Description
ACS510-01-017A-4 moves the ACS510 family into frame R2 with a 7.5 kW normal-use rating and 17 A output for 380-480 V three-phase motor applications.

ACS510-01-017A-4 provides adjustable-speed control, local commissioning, configurable I/O, and Modbus communication for engineered fan, pump, and conveyor systems while retaining the internal brake chopper used in R1-R2 units.

ACS510-01-017A-4 must be checked for R2 mounting depth, motor and overload demand, braking energy, input protection, cable entry, cooling air, EMC routing, command ownership, and service access before replacing or expanding an installation.
Alternative Names
ACS510 01 017A 4 ACS51001017A4 3ABD00015747-D ABB ACS510-01-017A-4 ABB 3ABD00015747-D ACS510 7.5 kW drive 17 A R2 wall-mounted drive ABB general purpose drive 7.5 kW
Technical notes
ACS510-01-017A-4 is the first listed 7.5 kW configuration using frame R2, so do not assume the mechanical fit of an R1 unit. Verify the documented 17 A duty, 16 A IEC fuse basis, mounting depth, cooling path, conductor access, internal brake-chopper application, motor cable, earthing, control wiring, and parameter migration before installation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can ACS510-01-017A-4 replace an R1 drive without panel changes?
Do not assume so: this 17 A configuration uses frame R2 and requires its own mounting, cable-entry, terminal-access, and 88 m³/h airflow review. Recheck protection, conductors, motor duty, braking, I/O, and approved drawings before treating it as a panel-compatible replacement.
How should the ACS510-01-017A-4 internal braking arrangement be checked for 7.5 kW duty?
ACS510-01-017A-4 uses the R2 internal brake-chopper arrangement, but resistor suitability depends on inertia, regenerative torque, stopping time, cycles per hour, energy, power, and thermal protection. Verify the complete duty rather than selecting a resistor from motor power alone.
Why might an ACS510-01-017A-4 motor accelerate slowly even when a short ramp is entered?
Compare actual current with the ACS510-01-017A-4 17 A rating and inspect current limiting, motor data, load inertia, mechanical drag, supply voltage, process permissives, speed limits, and reference restrictions. This shows whether the R2 drive is torque-limited or being held back by controls.
Which wiring checks are specific to the ACS510-01-017A-4 R2 installation?
Before energizing ACS510-01-017A-4, coordinate the official 16 A IEC fuse basis with conductor sizing, then verify PE continuity, phase identification, terminal torque, shield termination, cable separation, control common, brake-resistor wiring, and output-contactor logic. These checks address both the R2 power and control layout.
How can ACS510-01-017A-4 faults be diagnosed without losing evidence?
Record the exact fault, operating current relative to 17 A, command source, speed, DC-bus state, process condition, recent changes, and timestamps before resetting. The captured R2 operating context helps distinguish overload, braking, wiring, supply, and control-sequence causes.
What should an ACS510-01-017A-4 replacement quotation identify?
State ACS510-01-017A-4, Product ID 3ABD00015747-D, the 7.5 kW and 17 A duty, R2 installation, 16 A fuse basis, motor nameplate, braking resistor, I/O and Modbus use, quantity, destination, inspection scope, and required date. These anchors prevent an R1 configuration from being supplied.