Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power assists with R4 cooling records, pump commissioning data, quotations, and sourcing coordination.

ACS550-01-059A-4

/ 4.9
1001 reviews | Need a Specific Revision?
The 59 A ABB ACS550-01-059A-4 moves 30 kW pump and utility control into frame R4, making enclosure airflow and cable planning central.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS550-01-059A-4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS550-01-059A-4

  • Manufacturer:
    ABB
  • Part Number:
    ACS550-01-059A-4
  • Product Family:
    ABB Drives
  • Product Type:
    ACS550 General Purpose Drive
  • Stock:
    1
  • Supply Voltage:
    3-phase 380 ... 480 V AC
  • Input Frequency:
    48 ... 63 Hz
  • Normal Output Current:
    59 A
  • Normal Output Power:
    30 kW
  • Heavy-duty Output Current:
    45 A
  • Heavy-duty Output Power:
    22 kW
  • Frame Size:
    R4
  • Degree of Protection:
    IP21
  • Mounting:
    Wall-mounted
  • Motor Control:
    Scalar and sensorless vector control
  • Embedded Communication:
    Modbus RTU
  • Analog Inputs:
    2
  • Analog Outputs:
    2
  • Digital Inputs:
    6
  • Relay Outputs:
    3
  • Weight:
    24 kg
  • Estimated shipping dimensions:
    20.3 x 59.6 x 26.2 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications R4 Cooling Pump Network

Features:

  • 59 A output moves ACS550 installations into frame R4
  • Pump commissioning through process feedback and coordinated interlocks
  • Cooling, cable, and communication-loss planning for 30 kW systems
ACS550-01-059A-4 combines a 30 kW normal-use duty with the larger R4 wall-mounted structure.

Its process value is clearest in pump systems where pressure or flow feedback, minimum speed, standby sequencing, permissives, and network supervision must work as one control strategy.

Project evidence should prove cabinet heat removal, conductor and PE preparation, motor-cable suitability, serial timeout behavior, and stable current across the required hydraulic operating range.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS550-01-059A-4 ACS550 Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS550-01-059A-4 ACS550 General Purpose Drive Specs

General

  • ManufacturerABB
  • ModelACS550-01-059A-4
  • ConditionNew Original ready stock
  • Product FamilyABB ACS550 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Higher-power enclosure planning

  • Heat path: Prevent exhaust air from returning to the drive inlet.
  • Clearances: Maintain the ABB mounting spaces and service access around frame R4.
  • Contamination: Set fan and heat-sink inspection intervals for the installed environment.
  • Baseline: Measure cabinet air and drive current during representative loaded operation.

30 kW hydraulic integration

  • Operating point: Compare motor current and pump curve across the intended flow range.
  • Minimum speed: Respect motor cooling, pump, seal, and process constraints.
  • Pressure logic: Validate transmitter scaling, PID direction, limits, and fallback behavior.
  • Sequencing: Coordinate valves, bypass, standby pumps, and restart permissions.

Embedded Modbus ownership

  • Topology: Use a documented RS-485 trunk with correct termination and shielding.
  • Commands: Define run, stop, reference, reset, and local override ownership.
  • Timeout: Agree the safe process response to missing or invalid communication.
  • Diagnostics: Archive addresses, serial settings, mappings, counters, and fault evidence.
Description
Large pump and utility panels use ACS550-01-059A-4 at the 30 kW, 59 A normal-use point of the ACS550 range. Its move to frame R4 increases the importance of enclosure airflow, conductor routing, structural support, and service access.

During pump commissioning, ACS550-01-059A-4 can coordinate motor speed with pressure or flow feedback, process limits, valve or standby logic, and embedded Modbus supervision. Rotation, minimum speed, PID direction, reference scaling, and current at representative operating points should be recorded.

An installation using ACS550-01-059A-4 should also define what happens when the serial command path is lost. The approved response, cooling maintenance, motor-cable limits, grounding, protection, and loaded recovery test belong in the final handover package.
Alternative Names
ACS550 01 059A 4 ACS55001059A4 ABB ACS550-01-059A-4 ABB ACS550 01 059A 4 ACS550 59 A 30 kW drive ABB ACS550 30 kW general purpose drive
Technical notes
ACS550-01-059A-4 uses the R4 frame and a 59 A normal-use rating, so complete the feeder, conductor, mounting, and enclosure heat calculations before installation. Verify the required cooling path, motor-cable length and insulation, external braking scope, IT-network EMC-filter instructions where applicable, embedded Modbus timeout behavior, lifting method, and maintenance access.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which enclosure conditions determine whether ACS550-01-059A-4 has adequate cooling?
Review the documented drive losses and airflow with ambient temperature, enclosure size and rating, filters, recirculation, altitude, neighboring heat sources, fan performance, contamination, and required thermal margin.
How should a 30 kW pump be commissioned with ACS550-01-059A-4?
Verify motor and pump data, rotation, valve state, minimum speed, ramps, pressure or flow scaling, PID direction, interlocks, standby sequencing, current at key operating points, and fault recovery.
Why can ACS550-01-059A-4 overheat even while its cooling fan runs?
Inspect airflow direction, blocked heat sink, dirty filters, exhaust recirculation, high cabinet temperature, insufficient clearances, motor overload, switching frequency, altitude, and nearby heat-producing equipment.
If Modbus communication to ACS550-01-059A-4 fails, what process response must be defined?
The approved control philosophy must define timeout detection, retained or forced reference, run permission, alarm, local takeover, restart, and safe process response; test this behavior before handover.
When evaluating motor-cable length for ACS550-01-059A-4, which factors matter?
Use ABB limits together with cable capacitance and shielding, switching frequency, motor insulation, EMC requirements, route, grounding, output-filter needs, and bearing-current risk for the installed motor.
A sourcing request for ACS550-01-059A-4 should provide what evidence?
Provide the full type, motor and pump data, R4 mounting, supply and protection, cable length, cooling, braking, control and network scope, quantity, destination, condition, inspection, and schedule.

Product Browsing History