Features:
- General-purpose low-voltage AC drive for three-phase motor control.
- R1 wall-mounted construction with an IP21 enclosure.
- Automatic input-line identification simplifies drive commissioning.
The ordered ACS550-01-06A9-4 is the standard IP21 configuration identified by ABB product ID 3AUA0000002415-D. It is supplied as a complete drive module for panel installation.
The drive provides variable-frequency motor control for general-purpose industrial equipment where adjustable speed and controlled acceleration are required.
Before installation or replacement, verify the incoming supply, motor duty, enclosure version, frame clearance, protective devices, and control wiring against the complete ABB type designation.
Availability is confirmed for the ABB ACS550-01-06A9-4 configuration during quotation.
ABB ACS550-01-06A9-4 Frequency Converter Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Pump applications can use adjustable motor speed to match process flow requirements and reduce unnecessary motor operation.
- Fan systems can regulate motor speed for controlled airflow in general-purpose industrial equipment.
- Conveyors and mixers can use variable-speed control to adapt motor operation to changing process loads.
- Embedded Modbus RTU communication over EIA-485 allows supervisory systems to exchange drive commands, status information, and parameters.
- Optional fieldbus adapters extend ACS550 communication to PROFIBUS DP, DeviceNet, CANopen, ControlNet, Modbus TCP, and PROFINET networks.
- The SREA-01 Ethernet adapter provides a remote-monitoring path for drive status and operational information.
- The basic control panel provides local parameter setting and allows configured values to be copied from one drive to another.
- Two analog inputs accept voltage or current reference signals for speed, process, or control-command scaling.
- Six digital inputs support 12–24 V DC PNP or NPN control arrangements for external run and command logic.
- Normal-use overload capacity is 1.1 times I2N for one minute in each ten-minute operating period.
- Heavy-duty operation supports 1.5 times I2hd for one minute and 1.8 times I2hd for two seconds within the stated cycles.
- ABB specifies 10 A gG IEC or 10 A UL Class T input fuses for the ACS550-01-06A9-4 type designation.