Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB documentation, 11 kW selection, and cabinet integration guidance.

ACS580-01-026A-4 3AXD50000038960

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS580-01-026A-4 3AXD50000038960 is a 400 V ACS580-01 IP21 wall-mounted drive rated 25.0 A and 11 kW for general-purpose motor control.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS580-01-026A-4 3AXD50000038960
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS580-01-026A-4 3AXD50000038960

  • Manufacturer:
    ABB
  • Part Number:
    ACS580-01-026A-4 3AXD50000038960
  • Product Family:
    ABB Drives
  • Product Type:
    ACS580 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3AXD50000038960
  • Voltage Class:
    400 V
  • Nominal Output Current:
    25.0 A
  • Nominal Motor Power:
    11 kW
  • Maximum Current:
    30.6 A
  • Heavy-Duty Rating:
    17.0 A / 7.5 kW
  • Frame Size:
    R2
  • Maximum Losses:
    418 W
  • Protection:
    IP21 / UL Type 1
  • Control Panel:
    ACS-AP-S assistant control panel
  • Safety Function:
    Safe Torque Off integrated
  • EMC and Braking:
    Internal EMC C2 filter; integrated braking chopper
  • Weight:
    6.6 kg
  • Estimated shipping dimensions:
    12.5x47.3x22.9cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Commissioning EMC & Grounding Option Planning

Features:

  • General-purpose motor control: The 11 kW/25.0 A nominal-use rating covers common variable-torque and constant-torque applications.
  • Built-in engineering functions: Safe Torque Off, EMC filtering, an assistant panel, coated boards, and a braking chopper reduce external hardware.
  • Application flexibility: Motor macros, energy functions, optional fieldbus adapters, and configurable I/O support plant integration.
ACS580-01-026A-4 3AXD50000038960 balances motor-control capability with a compact R2 wall-mounted package for 400 V industrial systems.

The assistant panel supports commissioning and diagnostics, while the base hardware includes STO, EMC filtering, and a braking chopper; protocol adapters remain project-specific options.

Select the drive from measured motor current and duty, then validate the supply system, protection, cable, ventilation, EMC, control wiring, fieldbus, parameters, and fault-response plan.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-026A-4 3AXD50000038960 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-026A-4 3AXD50000038960 ACS580 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS580-01-026A-4 3AXD50000038960
  • ConditionNew Original ready stock
  • Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Startup and motor matching

  • Motor data: Enter the verified nameplate voltage, current, frequency, speed, and power.
  • Duty check: Use actual load torque, overload duration, ambient conditions, and switching frequency.
  • Direction test: Prove motor rotation and process interlocks before coupling the full load.
  • Record: Archive parameters, option codes, firmware, fault history, and acceptance results.

Supply-system compatibility

  • TN-S system: The internal EMC filter is intended for a symmetrically grounded TN-S supply.
  • Other systems: Follow ABB instructions before connecting to IT, corner-grounded delta, midpoint-grounded delta, or TT systems.
  • Protective earth: Use the required PE conductors, shield terminations, and cable routing.
  • Motor cable: Select cable construction and length against EMC and drive hardware limits.

Controls and communication scope

  • Fieldbus: Select the ABB adapter that matches the plant protocol and engineering tool.
  • I/O: Map every command, reference, interlock, and feedback signal before wiring.
  • Safety: Integrate STO into the machine safety function; it is not a general isolation device.
  • Braking: Verify whether the integrated chopper, an external resistor, and thermal protection are required.
Description
ACS580-01-026A-4 3AXD50000038960 is the 11 kW, 25.0 A nominal-use configuration in ABB’s ACS580-01 general-purpose drive family, designed to control standard induction and permanent-magnet motors in pumps, fans, conveyors, mixers, and similar industrial loads.

ACS580-01-026A-4 3AXD50000038960 uses frame R2 with a maximum current of 30.6 A, heavy-duty rating of 17.0 A/7.5 kW, an assistant control panel, internal EMC filtering, Safe Torque Off, coated boards, and an integrated braking chopper.

ACS580-01-026A-4 3AXD50000038960 simplifies cabinet and machine integration, but reliable operation still depends on correct motor sizing, overload duty, cable and fuse selection, earthing system, EMC configuration, ventilation, fieldbus options, and a validated startup record.
Alternative Names
ACS580-01-026A-4 ACS580 01 026A 4 ACS58001026A4 3AXD50000038960 ABB ACS580-01-026A-4
Technical notes
ACS580-01-026A-4 3AXD50000038960 is a R2, 400 V drive rated 25.0 A/11 kW nominal. Before energizing, verify motor nameplate data, overload duty, protective earth, cable and fuse sizing, STO wiring, and the supply earthing system. The internal EMC filter is intended for symmetrical TN-S networks and may require disconnection on IT, corner-grounded delta, midpoint-grounded delta, or TT systems.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When is ACS580-01-026A-4 3AXD50000038960 unsuitable for an 11 kW motor despite matching the nominal power?
ABB lists 25.0 A/11.0 kW nominal but 17.0 A/7.5 kW heavy duty. If the motor has repeated high-torque overloads, select from the heavy-duty point and measured current.
What protection values must be confirmed for ACS580-01-026A-4 3AXD50000038960 before energizing?
ABB lists a 32 A gG fuse with 256 A minimum installation short-circuit current, or a 40 A uR/aR fuse with 120 A minimum. Verify full coordination locally.
Why does the 418 W maximum loss of ACS580-01-026A-4 3AXD50000038960 require a separate thermal review?
This documented R2 loss is substantially above the 265 W of the 018A configuration. Recalculate enclosure temperature rise, airflow, spacing, ambient conditions, and neighboring heat sources.
How should the 30.6 A maximum current of ACS580-01-026A-4 3AXD50000038960 be interpreted during commissioning?
Do not use it as a continuous rating. ABB documents 25.0 A nominal and 17.0 A heavy-duty output, so motor current, overload duration, thermal state, and parameters govern operation.
Can ACS580-01-026A-4 3AXD50000038960 replace ACS580-01-018A-4 without changing cables or fuses?
No. Both use R2, but this model increases nominal current from 17.0 A to 25.0 A, gG protection from 25 A to 32 A, and losses from 265 W to 418 W.
What should a retrofit survey record before installing ACS580-01-026A-4 3AXD50000038960?
Record the 25.0 A/11.0 kW duty, motor nameplate, overload cycle, 32 A gG coordination, 256 A minimum fault current, R2 clearances, 418 W heat, earthing, STO, and fieldbus scope.