Features:
- 30 kW normal-use configuration rated 62 A
- R4 wall-mounted frame with IP21 protection
- Integrated control I/O, Modbus RTU, and Safe Torque Off
ACS580-01-062A-4 3AUA0000080498 is the R4 configuration for 30 kW general-purpose motor duties at 400 V.
The unit combines motor control, local commissioning resources, process I/O, serial connectivity, and machine-safety interfacing in a wall-mounted drive.
The purchasing package should identify motor and load data, R4 mounting space, power protection, cable routes, network and I/O requirements, safety validation, environmental limits, and the required options.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-062A-4 3AUA0000080498 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-062A-4 3AUA0000080498 ACS580 General Purpose Wall-Mounted Drive Specs
General
- ManufacturerABB
- ModelACS580-01-062A-4 3AUA0000080498
- ConditionNew Original ready stock
- Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
R4 mechanical preparation
- Mounting surface: Confirm load capacity, fastener positions, and flatness for the R4 unit.
- Clearances: Keep the documented spaces above, below, and beside the enclosure.
- Cable entry: Coordinate supply, motor, PE, STO, and control-cable routing before installation.
- Service access: Allow safe access to the panel, terminals, fans, and removable covers.
30 kW feeder and motor circuit
- Protection: Coordinate fuse type and rating with the available fault current and local rules.
- Conductors: Size supply, motor, and PE conductors for current, temperature, and installation method.
- Earthing: Verify the network type before applying the drive EMC and varistor instructions.
- Control power: Document every control and safety interface, common, and shield termination.
Maintainability review
- Cooling: Keep the fan path clean and include inspection access in the cabinet layout.
- Parameters: Maintain a controlled backup of the accepted drive configuration.
- Fault history: Capture codes, time, speed, current, and process state before clearing events.
- Spares: Define control panel, adapters, and approved service parts separately from the base drive.