ACS880-01-025A-3 3AUA0000107992

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS880-01-025A-3 3AUA0000107992 is a 11 kW, 25 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R2.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-025A-3 3AUA0000107992
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-025A-3 3AUA0000107992

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-025A-3 3AUA0000107992
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000107992
  • Nominal Motor Power:
    11 kW
  • Normal Output Current:
    25 A
  • Light-Duty Rating:
    24 A / 11 kW
  • Heavy-Duty Rating:
    17 A / 7.5 kW
  • Maximum Output Current:
    29 A
  • Frame Size:
    R2
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    17 kVA
  • Power Consumption:
    412 W
  • Sound Pressure:
    59 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    8.4 kg
  • Estimated shipping dimensions:
    57.4x30.4x25.6cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Motor Matching Installation Startup

Features:

  • 11 kW and 25 A normal-use rating at 400 V
  • R2 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-025A-3 3AUA0000107992 is the 11 kW, 25 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-025A-3 3AUA0000107992 uses the R2 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-025A-3 3AUA0000107992 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-025A-3 3AUA0000107992 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-025A-3 3AUA0000107992 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-025A-3 3AUA0000107992
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

11 kW application review

  • Nameplate current: Check actual motor current against the 25 A normal-use and 17 A heavy-duty ratings.
  • Load duty: Document torque characteristic, overload duration, starting demand, inertia, ramps, and braking behavior.
  • Motor system: Confirm motor insulation, cable length, switching conditions, speed range, and required filtering.
  • Derating: Apply the official altitude, temperature, enclosure, and switching-frequency instructions where relevant.

R2 mounting and electrical checks

  • Mounting: Use the approved R2 orientation, fasteners, clearances, and service-access arrangement.
  • Protection: Coordinate isolation, fuses, conductors, prospective fault current, and local electrical requirements.
  • Earthing: Complete PE, cable-shield, EMC, and supply-system checks before power-up.
  • Control wiring: Separate power and control routes and verify I/O, Safe Torque Off, and option-module connections.

R2 commissioning sequence

  • Motor data: Enter and verify the complete nameplate values before the approved identification routine.
  • Direction: Prove rotation with the process uncoupled or otherwise placed in a safe test condition.
  • Interlocks: Test enable, stop, Safe Torque Off, process permissives, references, and network-loss behavior.
  • Records: Archive the accepted parameters, firmware, option codes, readings, fault history, and recovery plan.
Description
ACS880-01-025A-3 3AUA0000107992 provides the 11 kW, 25 A normal-use rating within the ACS880-01 wall-mounted drive platform, retaining the compact R2 frame, IP21 protection, and 380–415 V three-phase input range.

ACS880-01-025A-3 3AUA0000107992 uses ABB Direct Torque Control and the integrated control resources to regulate motor speed and torque while exchanging commands, references, interlocks, and feedback with the engineered control system.

ACS880-01-025A-3 3AUA0000107992 requires the application duty to be checked against its 24 A light-duty and 17 A heavy-duty ratings, followed by verification of feeder protection, conductor sizing, EMC practice, braking scope, I/O ownership, and commissioning access.
Alternative Names
ACS880 01 025A 3 ACS88001025A3 3AUA0000107992 ABB ACS880-01-025A-3 ABB ACS880-01-025A-3 3AUA0000107992 ACS880 11 kW R2 wall mounted drive ACS880-01-025A-3 25 A industrial drive
Technical notes
Release ACS880-01-025A-3 3AUA0000107992 only after the load profile has been checked against the 25 A normal-use, 24 A light-duty, and 17 A heavy-duty ratings. Confirm the 380–415 V supply, R2 mounting clearances, protective device coordination, cable and PE design, ventilation, Safe Torque Off circuit, motor data, and selected option modules.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can the 11 kW label alone justify selecting ACS880-01-025A-3 3AUA0000107992 for a variable-torque or overload duty?
No. Compare the motor nameplate and load profile with the 25 A normal-use, 24 A light-duty, and 17 A heavy-duty points. The governing current and overload duration, not the power label by itself, should control selection.
Before ACS880-01-025A-3 3AUA0000107992 is assigned to repetitive stopping, how should the 25 A R2 application be checked for regenerative duty?
Calculate regenerated energy, peak braking power, stop time, repetition rate, and thermal duty. Confirm the required chopper, resistor, protection, and safe stopping arrangement from the approved ABB configuration instead of assuming they are included.
What does a 29 A output event indicate when troubleshooting acceleration with ACS880-01-025A-3 3AUA0000107992?
Treat 29 A as a documented maximum output point, not a continuous operating target. Review motor data, load inertia, ramp demand, current limits, mechanical condition, cable condition, supply quality, and the selected normal or heavy-duty basis.
Which motor data controls should be completed before Direct Torque Control is commissioned on ACS880-01-025A-3 3AUA0000107992?
Verify the full motor nameplate, connection, rated voltage, current, frequency, speed, and power before the approved identification procedure. Record the accepted values and do not reuse parameters from another drive without engineering review.
Why should an existing R2 drive not be treated as a drop-in match for ACS880-01-025A-3 3AUA0000107992 solely because the frame is the same?
The Product ID, 25 A duty basis, terminal arrangement, protection, motor and braking requirements, I/O assignment, option codes, firmware, parameters, and safety circuit must all be compared with approved drawings before replacement.
For an RFQ involving ACS880-01-025A-3 3AUA0000107992, which duty details matter beyond quantity and destination?
Provide motor and load data, normal versus light or heavy-duty requirement, supply and earthing, stopping profile, enclosure and cooling conditions, communication and option scope, safety circuit, inspection requirements, and the complete Product ID.