ACS880-01-045A-3 3AUA0000108020

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS880-01-045A-3 3AUA0000108020 is a 22 kW, 45 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R4.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-045A-3 3AUA0000108020
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-045A-3 3AUA0000108020

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-045A-3 3AUA0000108020
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000108020
  • Nominal Motor Power:
    22 kW
  • Normal Output Current:
    45 A
  • Light-Duty Rating:
    43 A / 22 kW
  • Heavy-Duty Rating:
    38 A / 18.5 kW
  • Maximum Output Current:
    64 A
  • Frame Size:
    R4
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    31 kVA
  • Power Consumption:
    526 W
  • Sound Pressure:
    64 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    18.6 kg
  • Estimated shipping dimensions:
    69.1x32.9x29cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Motor Matching Installation Startup

Features:

  • 22 kW and 45 A normal-use rating at 400 V
  • R4 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-045A-3 3AUA0000108020 is the 22 kW, 45 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-045A-3 3AUA0000108020 uses the R4 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-045A-3 3AUA0000108020 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-045A-3 3AUA0000108020 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-045A-3 3AUA0000108020 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-045A-3 3AUA0000108020
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

22 kW application review

  • Nameplate current: Check actual motor current against the 45 A normal-use and 38 A heavy-duty ratings.
  • Load duty: Document torque characteristic, overload duration, starting demand, inertia, ramps, and braking behavior.
  • Motor system: Confirm motor insulation, cable length, switching conditions, speed range, and required filtering.
  • Derating: Apply the official altitude, temperature, enclosure, and switching-frequency instructions where relevant.

R4 mounting and electrical checks

  • Mounting: Use the approved R4 orientation, fasteners, clearances, and service-access arrangement.
  • Protection: Coordinate isolation, fuses, conductors, prospective fault current, and local electrical requirements.
  • Earthing: Complete PE, cable-shield, EMC, and supply-system checks before power-up.
  • Control wiring: Separate power and control routes and verify I/O, Safe Torque Off, and option-module connections.

R4 commissioning sequence

  • Motor data: Enter and verify the complete nameplate values before the approved identification routine.
  • Direction: Prove rotation with the process uncoupled or otherwise placed in a safe test condition.
  • Interlocks: Test enable, stop, Safe Torque Off, process permissives, references, and network-loss behavior.
  • Records: Archive the accepted parameters, firmware, option codes, readings, fault history, and recovery plan.
Description
ACS880-01-045A-3 3AUA0000108020 places a 22 kW, 45 A normal-use rating in ABB’s R4 ACS880-01 wall-mounted drive construction for three-phase 380–415 V industrial motor systems.

ACS880-01-045A-3 3AUA0000108020 provides Direct Torque Control together with the documented control unit and hardwired I/O so the drive can manage motor operation, process references, permissives, feedback, and safety-related stop commands within the engineered scheme.

ACS880-01-045A-3 3AUA0000108020 should enter procurement only after the 43 A light-duty and 38 A heavy-duty limits, R4 installation clearances, supply protection, cable terminations, cooling, motor insulation, braking duty, option codes, and startup responsibilities are defined.
Alternative Names
ACS880 01 045A 3 ACS88001045A3 3AUA0000108020 ABB ACS880-01-045A-3 ABB ACS880-01-045A-3 3AUA0000108020 ACS880 22 kW R4 wall mounted drive ACS880-01-045A-3 45 A industrial drive
Technical notes
Plan ACS880-01-045A-3 3AUA0000108020 as an R4 power installation, not only as a 22 kW selection. Verify the 45 A normal-use and 38 A heavy-duty points, 380–415 V supply, fault-current and protection study, cable and PE terminations, airflow, braking demand, Safe Torque Off wiring, selected communications, and controlled first-power procedure.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which operating profile makes the 38 A heavy-duty rating more relevant than the 45 A normal-use value for ACS880-01-045A-3 3AUA0000108020?
Use the heavy-duty point when the documented load profile requires repeated or sustained overload beyond normal-use assumptions. Compare motor current, torque, acceleration, process peaks, and recovery time with 38 A and 18.5 kW before approval.
For an R4 panel, how should engineers account for the 526 W loss associated with ACS880-01-045A-3 3AUA0000108020?
Add the documented loss to the enclosure heat balance and evaluate ambient temperature, neighboring heat sources, airflow, inlet condition, and ABB derating requirements. The cooling arrangement must preserve the specified clearances and service access.
If ACS880-01-045A-3 3AUA0000108020 records a 64 A peak but the motor does not complete acceleration, what should be tested before increasing limits?
Check motor nameplate entries, connection, load torque, inertia, ramp command, mechanical binding, cable condition, and supply quality. Compare the event duration with the 45 A normal and 38 A heavy-duty basis before changing protection or limits.
What must the feeder study establish before the 45 A R4 configuration of ACS880-01-045A-3 3AUA0000108020 is connected?
Confirm supply system and earthing, prospective fault current, isolation, approved protective device, conductor and PE sizing, terminal capacity, cable routing, and local requirements. These decisions must come from the project study and ABB instructions.
A start command is present but torque is inhibited: how should the Safe Torque Off circuit be checked on ACS880-01-045A-3 3AUA0000108020?
Use the approved diagnostic sequence to verify external safety demand, wiring continuity, terminals, interlocks, and status indications. Correct the safety cause and complete the authorized functional test rather than bypassing the circuit.
Before another 22 kW drive is replaced by ACS880-01-045A-3 3AUA0000108020, which comparison evidence should the engineer sign off?
Compare full identifiers, 43 A light-duty and 38 A heavy-duty requirements, R4 mounting, terminals, cooling, protection, motor cable, braking, I/O, options, firmware, parameters, safety functions, and approved drawings.