Allen-Bradley 2198-H040-ERS is a Frame 2 Kinetix 5500 three-phase Servo Drive with 13.0 A rms continuous output.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2198-H040-ERS
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2198-H040-ERS

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2198-H040-ERS
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Kinetix 5500 Servo Drive
  • Stock:
    1
  • Frame:
    Frame 2
  • Input Supply:
    195...264 V rms three-phase; 324...528 V rms three-phase
  • Output Power:
    4.0 kW at 230 V three-phase; 8.3 kW at 480 V three-phase
  • Continuous Output Current:
    13.0 A rms; 18.4 A 0-pk
  • Peak Output Current:
    32.5 A rms; 45.9 A 0-pk
  • Network:
    Integrated Motion over EtherNet/IP
  • Safety:
    Hardwired Safe Torque Off
  • Dimensions:
    5.5 × 22.5 × 26.5 cm
  • Weight:
    2.3 kg
  • Tariff Code:
    8503009090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Diagnostics Grounding Cooling Applications
  • Frame 2 Kinetix 5500 platform for one higher-current servo axis
  • Integrated Motion over EtherNet/IP links the drive with a supported Logix controller
  • Hardwired Safe Torque Off connects to the validated machine safety circuit

Allen-Bradley 2198-H040-ERS operates as one axis within a complete Kinetix 5500 system using a supported controller, motor, feedback device, brake option, and approved cable.

Its documented operating points cover 230 V and 480 V three-phase installations, and the actual supply and axis duty must be established before sizing.

Confirm controller and drive firmware, motor-feedback pairing, cable set, branch protection, regeneration, grounding, shield bonding, enclosure airflow, and safety validation before commissioning.

Availability, condition, price, and shipping time for 2198-H040-ERS are confirmed during quotation.

Allen-Bradley 2198-H040-ERS Kinetix 5500 Servo Drive Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Drive and axis fault information is available through the Logix motion connection
  • DSL feedback provides motor-temperature information for supported motor combinations
  • Solid-state motor overload protection uses the documented drive thermal model
  • Bond the drive and enclosure according to the Kinetix 5500 installation instructions
  • Use the documented shield clamps and connector hardware for motor cabling
  • Verify the grounding-screw configuration for the installed power-source arrangement
  • Install the drive upright to maintain the specified airflow direction
  • Provide 40 mm airflow clearance above and below the drive
  • Use an enclosure with at least the documented 300 mm cabinet depth
  • Higher-current single-axis motion integrated with a supported Logix controller
  • 230 V three-phase installations using the documented 4.0 kW operating point
  • 480 V three-phase installations using the documented 8.3 kW operating point
Description
Allen-Bradley 2198-H040-ERS is a Frame 2 Kinetix 5500 Servo Drive for one higher-current Logix-integrated motion axis. It uses Integrated Motion over EtherNet/IP and hardwired Safe Torque Off.

Rockwell documents 4.0 kW at 230 V three-phase and 8.3 kW at 480 V three-phase. Output ratings are 13.0 A rms continuous and 32.5 A rms peak.

Before installation or replacement, verify the supply, motor-feedback combination, brake option, approved 2090 cable, controller and firmware, branch protection, regeneration, enclosure cooling, grounding, and Safe Torque Off circuit.
Alternative Names
2198-H040-ERS 2198H040ERS 2198 H040 ERS Allen-Bradley 2198-H040-ERS Allen Bradley 2198-H040-ERS AB 2198-H040-ERS Rockwell Automation 2198-H040-ERS Kinetix 5500 2198-H040-ERS
Technical notes
Allen-Bradley 2198-H040-ERS requires three-phase input; verify the 230 V or 480 V operating point, axis duty, regeneration, and motor-feedback-cable combination.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What enclosure review is required for Allen-Bradley 2198-H040-ERS?
Rockwell specifies upright mounting, 40 mm airflow clearance above and below, no required left/right clearance, and a minimum cabinet depth of 300 mm. The thermal design must also account for the installed axis duty.
Which branch-circuit fuse is documented for Allen-Bradley 2198-H040-ERS?
Rockwell lists KTK-R-25 for the documented 240 V and 480 V three-phase conditions. Confirm the installed circuit and applicable standards before final selection.
How is motor temperature monitored with Allen-Bradley 2198-H040-ERS?
In supported DSL motor-feedback combinations, motor-temperature data is carried through the single motor cable. Verify the exact motor and cable catalog numbers.
Which controller families can integrate Allen-Bradley 2198-H040-ERS?
The Kinetix 5500 user manual documents supported systems using ControlLogix 5570/5580, GuardLogix 5570, CompactLogix 5370, and Compact GuardLogix 5370 families.
What should be checked when regenerative duty is high for Allen-Bradley 2198-H040-ERS?
Use Rockwell sizing resources to evaluate motor and load inertia, speed, deceleration, cycle repetition, vertical-load behavior, bus configuration, shunt requirements, and enclosure thermal conditions.
Can Allen-Bradley 2198-H040-ERS replace a lower-current Kinetix 5500 drive directly?
Not solely by current rating. Confirm supply, motor winding, feedback and brake interfaces, cable set, controller and firmware, physical installation, protection, regeneration, grounding, and safety wiring.
Which information is useful when sourcing Allen-Bradley 2198-H040-ERS?
Provide the complete catalog number, clear nameplate photos, machine supply, installed motor and feedback numbers, cable information, controller family, required quantity, and condition.