Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports frame verification, official-document supply, responsive quotations, and retrofit sourcing coordination.

25B-D024N104

/ 4.9
1001 reviews | Need a Specific Revision?
Screw-mounted Frame D construction distinguishes Allen-Bradley 25B-D024N104 as the 24 A PowerFlex 525 option for documented 11 kW machine duties.
In Stock
Ships by Tuesday, November 3
Fast Shipping Available
Get a quick price for 25B-D024N104
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 25B-D024N104

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    25B-D024N104
  • Product Family:
    PowerFlex
  • Product Type:
    AC Drive
  • Stock:
    1
  • Input:
    380–480 V AC, three phase
  • Output current:
    24 A
  • Motor rating:
    11 kW / 15 HP
  • Frame:
    D
  • Mounting:
    Screw mount
  • Enclosure:
    IP20 NEMA/Open Type
  • EMC filter:
    Not included
  • Weight:
    3.9 kg
  • Estimated shipping dimensions:
    13.0 × 26.0 × 21.2 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Duty Selection UL Protection Panel Installation Product Applications

Features:

  • Mechanical transition: Frame D introduces screw mounting for this 24 A drive
  • Exact load point: the official row supports the documented 11 kW / 15 HP duty
  • Integrated platform: EtherNet/IP, braking hardware, and STO remain within the PowerFlex 525 architecture
A quick identification should start with the larger Frame D package and the N104 suffix rather than the family name alone.

The mounting change affects panel preparation, cable access, airflow, and outage duration even when technicians already know PowerFlex 525 controls.

Electrical release then depends on the exact protection row and motor duty, not on the fact that another current rating uses the same frame.

Apter Power can support 25B-D024N104 frame verification, official documentation, quotation, and retrofit sourcing coordination.
25B-D024N104 Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Current basis: match the load to the exact 24 A rating
  • Motor rating: verify the 11 kW / 15 HP nameplate and duty profile
  • Dynamic demand: include acceleration, deceleration, and overload needs in the review
  • Exact row: select branch protection from the official catalog entry for this drive
  • Installation code: reconcile Rockwell tables with the applicable regional requirements
  • Documentation: retain fuse or breaker details in the panel record
  • Frame D: use screw mounting rather than a DIN-rail assumption
  • Cabinet space: plan around the documented 13.0 × 26.0 × 21.2 cm envelope
  • Heat path: preserve airflow and apply published derating rules when required
  • Machine drives: regulate speed and torque for a matched 11 kW / 15 HP motor
  • Panel integration: install the screw-mounted drive in a documented open-type enclosure
  • Connected control: exchange supported commands and diagnostics over EtherNet/IP
Description
Moving into the screw-mounted Frame D format, 25B-D024N104 supplies 24 A for documented 11 kW / 15 HP motor applications. The 380–480 V, non-filtered configuration uses an IP20 NEMA/Open Type enclosure.

The frame change gives 25B-D024N104 a different retrofit footprint from lower-current Frame C drives. Panel structure, cable approach, ventilation, and fastening must be planned before the common PowerFlex 525 control platform can simplify recommissioning.

Embedded EtherNet/IP, the brake transistor, and Safe Torque Off remain available on 25B-D024N104, but protection and motor selection must follow the exact 24 A catalog row. The 30 A unit that shares Frame D does not establish electrical equivalence.
Revisions

Revision Part #

Also known as

25B-D024N104 Series 1
25B-D024N104 Series 1
Alternative Names
Allen-Bradley 25B-D024N104 Rockwell Automation 25B-D024N104 25B D024 N104 25BD024N104 PowerFlex 525 11 kW drive PowerFlex 525 15 HP drive
Technical notes
A retrofit from a Frame C drive can fail mechanically even when the family name matches 25B-D024N104. This 24 A unit uses the larger screw-mounted Frame D arrangement; confirm panel cutout, support, cable entry, airflow, and service clearance before transferring control hardware or scheduling the installation outage.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should 25B-D024N104 be distinguished from the 30 A drive that shares Frame D?
Use the exact 24 A catalog number, 11 kW / 15 HP rating, motor-load study, and parameter record. Shared dimensions do not make the higher-current unit electrically or operationally equivalent.
What changes when 25B-D024N104 is mounted after a smaller Frame C PowerFlex 525?
Plan for the larger Frame D envelope and screw mounting, then recalculate cabinet layout, airflow, cable routing, and fastener requirements. Stop installation if spacing or heat rejection cannot meet the official conditions.
Why can existing branch protection become unsuitable when 25B-D024N104 replaces a smaller Frame C drive?
The 24 A Frame D catalog row has its own fuse or circuit-breaker coordination. Recalculate from the actual supply fault level, conductors, disconnect, and regional code; stop the retrofit if the installed protection cannot satisfy the official selection.
How can the integral brake transistor of 25B-D024N104 be evaluated for a high-inertia stop?
Calculate or measure regenerative energy and stop frequency, then select only the supported braking arrangement. If the duty exceeds the documented capability, revise the stop profile or engineering design before commissioning.
What should be verified before an existing EtherNet/IP program controls 25B-D024N104?
Compare the drive profile, firmware context, IP settings, command source, reference source, I/O mapping, and fault actions with the approved controller project. Perform a controlled no-load or decoupled test first.
Which procurement details prevent a frame-only mismatch for 25B-D024N104?
State the complete catalog number, Series 1, 24 A rating, 11 kW / 15 HP duty, N104 filter code, Frame D mounting, motor data, and required documentation on the RFQ and receiving checklist.

Product Browsing History