Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

X20IF10E1-1

/ 4.9
1001 reviews | Need a Specific Revision?
B&R X20IF10E1-1 is a PROFINET IO controller module with two shielded RJ45 ports and an integrated Ethernet switch for the X20 System.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for X20IF10E1-1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for X20IF10E1-1

  • Manufacturer:
    B&R
  • Part Number:
    X20IF10E1-1
  • Product Family:
    B&R X20 System
  • Product Type:
    PROFINET IO Controller Module
  • Stock:
    1
  • Physical layer:
    100BASE-TX
  • Ports:
    2 shielded RJ45 ports, integrated switch
  • Transfer rate:
    100 Mbit/s
  • Duplex modes:
    Half-duplex and full-duplex
  • Maximum segment length:
    100 m between two stations
  • Controller:
    netX100
  • Memory:
    8 MB SDRAM
  • Supported slots:
    X20 PLC or expandable bus controller X20BC1083
  • Power consumption:
    2 W
  • Degree of protection:
    IP20
  • Operating temperature:
    -25 to 60 °C horizontal; -25 to 50 °C vertical
  • Tariff Code:
    8538900000
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Host Support Network Commissioning Application
  • Adds PROFINET IO controller functionality to a supported X20 host
  • Provides two switched shielded RJ45 ports for line cabling
  • Supports 100BASE-TX, full duplex, autonegotiation, and Auto-MDI/MDIX

X20IF10E1-1 is a B&R profinet io controller module designed for the X20 System.

The module adds PROFINET IO controller capability to an X20 controller or expandable X20BC1083 and supports bidirectional data exchange with external PROFINET equipment.

Before installation or replacement, verify the complete material number, host compatibility, PROFINET device names and addresses, GSDML and project configuration, topology, cable and segment length, cycle requirements, firmware compatibility, and saved device parameters.

Availability, condition, price, and shipping time for X20IF10E1-1 are confirmed during quotation.

B&R X20IF10E1-1 PROFINET IO Controller Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • The module installs in a supported X20 PLC interface slot
  • It can also operate in the expandable X20BC1083 POWERLINK bus controller
  • Host hardware and Automation Studio support must be verified before installation
  • The interface operates as a PROFINET IO controller for connected devices
  • Two shielded RJ45 ports are linked through an integrated Ethernet switch
  • Each copper segment supports a documented maximum length of 100 meters
  • PROFINET device names and addressing must match the controller project
  • The correct device-description files and module configuration are required
  • Module, network, and data-transfer indicators support commissioning diagnostics
  • Integrating third-party PROFINET IO devices into B&R control systems
  • Bidirectional process-data exchange between X20 controllers and PROFINET equipment
  • Daisy-chain PROFINET installations using the integrated two-port switch
Description
X20IF10E1-1 is a B&R profinet io controller module for the X20 System automation platform.

It provides a 100BASE-TX PROFINET IO controller interface for integrating third-party devices, with full-duplex support, autonegotiation, Auto-MDI/MDIX, and two switched RJ45 ports.

Before installation or replacement, confirm the complete material number, host compatibility, PROFINET device names and addresses, GSDML and project configuration, topology, cable and segment length, cycle requirements, firmware compatibility, and saved device parameters.
Alternative Names
X20IF10E1-1 X20 IF 10E1-1 X20-IF10E1-1 X20IF10E11 B&R X20IF10E1-1 BR X20IF10E1-1
Technical notes
X20IF10E1-1 is a PROFINET IO controller for an X20 PLC or X20BC1083; verify host slot support, device names, GSDML files, topology, 100 m segments, firmware, and saved network configuration before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which hosts support B&R X20IF10E1-1?
B&R specifies installation in supported X20 PLCs and the expandable X20BC1083 bus controller; confirm the exact host hardware and Automation Studio support before ordering.
Can B&R X20IF10E1-1 connect PROFINET devices in a line?
Yes. Its two RJ45 ports are connected through an integrated switch, but each segment must meet the documented copper-cabling and length requirements.
What should be checked when a device is not detected by B&R X20IF10E1-1?
Verify the PROFINET device name, IP configuration, GSDML version, configured slot and subslot data, cable, port LEDs, device power, network topology, and controller project.
Does B&R X20IF10E1-1 operate as a PROFINET device?
Its documented role is PROFINET IO controller, so do not select it when the application requires the B&R station itself to behave as an IO device.
Can standard Ethernet traffic assumptions be applied to B&R X20IF10E1-1?
Treat it as an industrial PROFINET controller interface and design topology, update times, device configuration, and diagnostics according to the PROFINET project rather than office-network practice.
What firmware checks matter when replacing B&R X20IF10E1-1?
Confirm Automation Studio hardware support, the installed module firmware, host compatibility, device-description versions, and whether the validated project requires a specific upgrade package.
What should be backed up before replacing B&R X20IF10E1-1?
Save the complete PROFINET configuration, device names and addresses, GSDML versions, topology, update settings, diagnostics mapping, module firmware information, and controller project.