Features:
- True Interchangeability Eliminates Bench Calibration
- Armored Cable for Extreme Mechanical Protection
- API 670 Compliance with Hazardous Area Certifications
The Bently Nevada 330102-00-16-10-02-05 guarantees ±5% scale factor accuracy across any 3300 XL system component. You can swap probes, extension cables, or Proximitor sensors in the field without recalibrating the entire loop — reducing downtime from hours to minutes.
Unlike standard probes, the Bently Nevada 330102-00-16-10-02-05 integrates a flexible stainless steel armor over FEP-insulated triaxial cable. This withstands 330 N pull tension, resists crushing from maintenance access, and prevents cutting when routed through existing conduit or tight casing penetrations.
Certified to CSA, ATEX, and IECEx for Class I, Zone 0/2 and Division 2 environments, the Bently Nevada 330102-00-16-10-02-05 meets API 670 mechanical configuration and temperature stability requirements. It operates from -52°C to +177°C, ensuring reliable performance in steam turbines and gas compressors without external conduit or metallic housings.
The 330102-00-16-10-02-05 Bently Nevada 3300 XL 8 mm Armored Proximity Probe may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 330102-00-16-10-02-05 3300 XL 8 mm Armored Proximity Probe Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Bently Nevada 330102-00-16-10-02-05 3300 XL 8 mm Armored Proximity Probe
General
- Manufacturer GE / Bently Nevada
- Model 330102-00-16-10-02-05
- Condition New Original ready stock
- Product Family 330102-00-28-10-02-05,330102-00-16-10-02-00,330102-36-80-10-02-05
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Steam & Gas Turbine Monitoring – Measures radial vibration and axial thrust position in high-speed rotating machinery, especially where bearing housings are oil-wetted or require armored cable routing.
- Compressor Shaft Vibration – Installed in centrifugal and reciprocating compressors to detect shaft rub, imbalance, or subsynchronous vibration before unplanned trips occur.
- Keyphasor & Speed Detection – Provides a once-per-turn reference pulse for phase measurement and zero-speed detection on large generator sets.
- Hydro Turbine & Pump Condition Monitoring – Withstands humidity up to 93% for 56 days (IEC 68-2-3), making it suitable for hydropower tailwater or pump bearing applications.
- API 670 (5th Edition) – Fully compliant for mechanical configuration, linear range, accuracy, and temperature stability — required for refinery and offshore critical machinery.
- ATEX/IECEx (Ex ia IIC T4/T5 Ga) – Certified for intrinsically safe installation in Zone 0 explosive gas atmospheres when paired with approved barriers (Bently Nevada drawing 141092).
- cNRTLus (Class I, Div 2, Groups A–D) – Allows installation in North American industrial panels without metallic conduit, reducing material costs.
- CE & EMC (EN 61000-6-2/6-4) – Immunity for industrial environments and emissions compliance, ensuring trouble-free operation near VFDs, switchgear, or radio transmitters.
- Extended Temperature Range – The probe body and standard cable tolerate -52°C to +177°C, suitable for steam turbine casings and cold-weather compressor stations without external heating.
- High Humidity & Condensation – Passes 56-day 93% relative humidity testing with <3% scale factor drift, making it reliable in tropical climates or wash-down areas.
- Pressure Sealing (Differential) – Viton O-ring provides oil and gas containment up to the pressure rating of the mounting boss; however, Bently Nevada recommends periodic leak inspection for safety-critical applications.
- Mechanical Resilience (Armor) – The stainless steel armor withstands >330 N pull force and a 25.4 mm minimum bend radius, preventing damage during installation through tight conduit or after maintenance access.