Features:
- Accepts RTD (Pt100, Ni120, Cu10) and thermocouple (J, K, T, E) inputs; supports 3‑wire or 4‑wire RTDs; each channel individually configurable.
- Six isolated 4-20 mA outputs proportional to full‑scale temperature; 0.3662 μA/bit resolution; short‑circuit protected; update rate ≤100 ms.
- Alert and Danger setpoints adjustable 0-100% of full scale; programmable delays (1‑60 seconds); accuracy ±0.13%; functional safety certified (SIL 2).
The 3500/61 133811-02 provides six channels of temperature measurement, each independently configurable for RTD or thermocouple input. This allows a single monitor to handle mixed sensor types – for example, three RTDs for bearing temperatures and three thermocouples for exhaust gas temperatures. Supported RTDs include the industry‑standard 100Ω platinum (alpha = 0.00385 or 0.00392), 120Ω nickel, and 10Ω copper. Supported thermocouples are types J, K, T, and E. For RTDs, both 3‑wire and 4‑wire connections are supported
The 3500/61 133811-02 differs from the 3500/60 by providing dedicated 4-20 mA recorder outputs for each of its six channels. These analog outputs are proportional to the monitor’s full‑scale temperature range and are used to interface with plant DCS, PLC, or SCADA systems for trending, logging, and control. For example, a bearing temperature of 0-150°C might be mapped to 4-20 mA, allowing the DCS to continuously track temperature rise and initiate pre‑alarms before the monitor’s alert setpoint is reached.
The 3500/61 133811-02 is not just a data acquisition device – it is a machinery protection monitor. It continuously compares each channel’s temperature against user‑programmable Alert and Danger setpoints. When a setpoint is exceeded, the monitor activates alarms, which can be used to alert operators, trigger shutdowns, or log events. Alarm setpoints are adjustable from 0 to 100% of the channel’s full‑scale range, with accuracy within 0.13% of the desired value.
The 3500/61 133811-02 Bently Nevada Temperature Monitor may still be available for purchase and support from Apter Power beyond
End-Of-Life (EOL)by the manufacturer (OEM).
Bently Nevada 3500/61 133811-02 Temperature Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Bently Nevada 3500/61 133811-02 Temperature Monitor Specs
General
- Manufacturer Bently Nevada
- Model 3500/61 133811-02
- Condition New Original ready stock
- Product Family 3500/60 133811-01,3500/61 133811-03,3500/61 133811-04
Important Notice:Other accessories,manuals,cables,calibration data,software,etc.are not included with this equipment unless listed in the above stock item description.All prices are shown in USD.
- Bearing Temperature Monitoring: Monitors radial and thrust bearings in turbines, pumps, and compressors to detect early signs of mechanical wear or lubrication failure.
- Stator Winding Protection: Essential for large electric motors and generators to prevent insulation damage caused by electrical overloads or cooling system malfunctions.
- Exhaust & Fluid Monitoring: Tracks exhaust gas temperatures (EGT) in gas turbines and lube oil/coolant temperatures in auxiliary systems.
- Industrial Sectors: Widely used in Power Generation, Oil & Gas Refineries, Chemical Processing, and Water Treatment plants.
- Humidity: Up to 95% non-condensing, providing resilience in humid coastal or tropical plant locations.
- Electromagnetic Compatibility (EMC): Built to withstand high-interference environments near high-voltage switchgear and large motor drives, adhering to CE and CSA standards.
- Hazardous Areas: When used with appropriate barriers or in North American/ATEX-certified racks, it is suitable for use in Class 1, Division 2 or Zone 2 environments.
- High-Resolution Monitoring: Continuously digitizes analog temperature signals, allowing operators to see real-time trends via the System 1 software or local HMI.
- Setpoint Control (Alert/Danger): Users program specific temperature thresholds. When reached, the module sends signals to the 3500 Relay Modules to initiate alarms or emergency machine shutdowns (trips).
- Output Connectivity:Digital: Sends data via the 3500/22M TDI module to higher-level DCS or SCADA systems.
- Condition Monitoring: Beyond simple alarms, it provides "Not OK" status monitoring, identifying if a sensor has failed rather than triggering a false machine trip.