Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle Status

    Active / Available from OEM
    Apter Power provides official quotations, technical documentation, stock availability, and complete Orbit 60 system integration support.

60R/SIM01-00-00

/ 4.9
1001 reviews | Need a Specific Revision?
The Bently Nevada 60R/SIM01-00-00 is the central management and access gateway for the Orbit 60 Machinery Protection and Condition Monitoring System.
In Stock
Ships by Tuesday, October 27
Fast Shipping Available
Get a quick price for 60R/SIM01-00-00
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 60R/SIM01-00-00

  • Manufacturer:
    Bently Nevada
  • Part Number:
    60R/SIM01-00-00
  • Product Family:
    Orbit 60 Series
  • Product Type:
    System Interface Module
  • Stock:
    1
  • Power Consumption:
    Typical 7.6 Watts, Maximum 10.9 Watts
  • Module Form Factor:
    Single-wide slot
  • System Contacts:
    4 dedicated utility/rear contacts (Trip Multiply, Alarm Inhibit, System Reset, Configuration Lock)
  • System Contact Ratings:
    Max Voltage 24 Vdc, Current Rating <1 mA to 125 mA
  • Protection Fault Relay:
    Solid-state, SPDT (Single-Pole Double-Throw), 1 Vdc to 125 Vdc, 0.01 mA to 125 mA
  • Ethernet Communications:
    3 independent RJ-45 ports (1 public side, 2 utility side) supporting 1000/100/10 Base-T Auto-negotiation (Max cable length 100 meters / 328 feet)
  • Security & Encryption:
    IEC 62443-4-2 aligned, TLS encryption, PKI signed firmware, and physical Run/Program key lock switch
  • Estimated shipping dimensions:
    2.03 x 13.21 x 24.56 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Programming Integration Certifications & Standards

Features:

  • Central gateway module defining each Orbit 60 deployment across up to 68 dynamic channels.
  • Equipped with 3 independent Ethernet ports and 4 dedicated utility hardware contacts.
  • Features an onboard SPDT solid-state protection fault relay for machinery emergency safety switching.
The 60R/SIM01-00-00 model code specifies the standard System Interface Module configured without hazardous area certifications and without SIL system requirements.

It functions as the primary hub for system-level diagnostics, local display connections, and secure bi-directional configuration delivery to all connected modules.

The module must be installed in the slot immediately adjacent to the Power Input Module (PIM) and requires proper key-lock positioning to enable system edit rights.

The availability of this item is subject to confirmation by the manufacturer (OEM).
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Critical turbomachinery protection and continuous vibration monitoring systems.
  • Centralized condition monitoring for high-value industrial rotating equipment.
  • Unclassified general-purpose plant areas requiring IEC 62443 cyber-secure monitoring.
  • Maintains non-volatile internal memory to retain core module operational parameters and system identification data.
  • Enables real-time system configuration modification via Orbit Studio software over encrypted Ethernet connections.
  • Requires hardware contact closure or physical key unlocking to validate changes before pushing settings across the backplane.
  • Establishes high-speed internal backplane communications across all plugged measurement and relay modules in the rack.
  • Provides front-panel LED status indicators for instant visual feedback on power, system health, and link activity.
  • Interoperates seamlessly with external network infrastructure via standard auto-negotiating RJ-45 interface cabling.
  • Aligned with IEC 62443-4-2 industrial security requirements featuring TLS network encryption and PKI digitally signed firmware.
  • Designated under option code -00 for operation in unclassified general-purpose non-hazardous industrial locations.
  • Specified under option code -00 indicating no Functional Safety SIL certification requirement for the SIM gateway module.
Description
Bently Nevada 60R/SIM01-00-00 serves as the mandatory single access point for managing protection configurations, local displays, and system-level diagnostics within an Orbit 60 chassis. Occupying a single chassis slot adjacent to the Power Input Module, the 60R/SIM01-00-00 establishes seamless bi-directional communication with Orbit Studio software to distribute configurations securely across all network-connected modules.

Engineered for comprehensive machine safety control, the 60R/SIM01-00-00 incorporates four rear utility contacts for System Reset, System Alarm Inhibit, Trip Multiply, and Configuration Lock functions. The onboard Solid-State Single-Pole Double-Throw Protection Fault Relay continuously monitors system integrity, providing immediate hardware output switching during designated critical protection path faults.

Equipped with three independent auto-negotiating RJ-45 Ethernet ports, the 60R/SIM01-00-00 supports direct connections to NTP time servers, local displays, and network management software. Constructed with physical Run/Program key-lock controls and built in compliance with IEC 62443-4-2 cyber security standards, the 60R/SIM01-00-00 ensures tamper-proof industrial operation in unclassified general-purpose areas.
Alternative Names
60R/SIM01-00-00 60R-SIM01-00-00 60RSIM010000 60R SIM01 00 60R/SIM01-00 Bently Nevada 60R/SIM01-00-00 Orbit 60 60R/SIM01-00-00 60R/SIM01 System Interface Module
Technical notes
The 60R/SIM01-00-00 must be installed in the slot immediately adjacent to the Power Input Module (PIM) and requires proper key-lock positioning or contact closure to grant configuration edit permissions in Orbit Studio.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Is a SIL rating required for the Bently Nevada 60R/SIM01-00-00 in safety-instrumented Orbit 60 applications?
No, SIL certification is not required for the System Interface Module (60R/SIM01-00-00) even when deployed within an Orbit 60 safety system.
Where must the Bently Nevada 60R/SIM01-00-00 module be installed inside the Orbit 60 chassis?
The Bently Nevada 60R/SIM01-00-00 module occupies a single wide slot and must be installed in the slot directly adjacent to the Power Input Module (PIM).
What type of relay output is provided by the Bently Nevada 60R/SIM01-00-00?
The Bently Nevada 60R/SIM01-00-00 contains a solid-state Single-Pole Double-Throw (SPDT) Protection Fault Relay rated from 1 Vdc to 125 Vdc and 0.01 mA to 125 mA.
What physical system control contacts are integrated into the Bently Nevada 60R/SIM01-00-00?
The Bently Nevada 60R/SIM01-00-00 provides four utility contacts: System Reset (RST), System Alarm Inhibit (SAI), Trip Multiply (TM), and Configuration Lock (LOCK).
How does the Bently Nevada 60R/SIM01-00-00 secure system configurations against unauthorized changes?
Hardware security on the Bently Nevada 60R/SIM01-00-00 is enforced via a front-panel physical key-lock switch and a rear Configuration Lock contact, aligned with IEC 62443-4-2 cybersecurity standards.
What information is required when requesting a quote for the Bently Nevada 60R/SIM01-00-00?
Please provide the complete part number, the required quantity, the delivery location, etc.

Product Browsing History