Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle Status

    Active / Available from OEM
    Apter Power provides quotation, purchasing support, and system integration guidance for this module.

60R/PIM01-02-0

/ 4.9
1001 reviews | Need a Specific Revision?
The Bently Nevada 60R/PIM01-02-0 is a half-height redundant Power Input Module engineered specifically for 3U Orbit 60 Series chassis deployments.
In Stock
Ships by Tuesday, October 27
Fast Shipping Available
Get a quick price for 60R/PIM01-02-0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 60R/PIM01-02-0

  • Manufacturer:
    Bently Nevada
  • Part Number:
    60R/PIM01-02-0
  • Product Family:
    Orbit 60 Series
  • Product Type:
    Power Input Module
  • Stock:
    1
  • Input Voltage Range:
    +21 Vdc to +32 Vdc
  • Current Draw(3U 19" Full Load):
    7.1 Amps @ 24 Vdc (Maximum 8.6 Amps)
  • System Power Consumption (3U Full Load):
    Typical: 120 W, Maximum: 180 W
  • Module Form Factor:
    Half-height module
  • Diagnostic Indicator:
    Power OK LED (Green LED indicates input voltage levels are within acceptable limits)
  • Electrical Protection:
    Out-of-range protection (undervoltage non-damaging; overvoltage/overcurrent protected via internal replaceable fuse)
  • Operating Temperature:
    -30°C to +70°C (-22°F to +158°F)
  • Storage Temperature:
    -40°C to +85°C (-40°F to +185°F)
  • Operating & Storage Humidity:
    0% to 95% rH non-condensing
  • Hazardous Area Approvals:
    CSA/NRTL/C (Class I, Div 2 / Zone 2), ATEX / IECEx (Ex ec nC IIC T4 Gc)
  • Functional Safety Architecture:
    Compatible with SIL 1 simplex and SIL 2 redundant system configurations
  • Estimated shipping dimensions:
    2.03 x 13.21 x 24.56 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Performance Compatibility & Interoperability Firmware & Updates

Features:

  • Accepts wide range direct current input from +21 Vdc to +32 Vdc for flexible power integration.
  • Supports online insertion and removal (hot-swapping) in dual redundant power module configurations.
  • Includes an internal field-replaceable fuse for overvoltage and overcurrent circuit protection.
The 60R/PIM01-02-0 is a factory-configured 3U half-height Power Input Module specifically engineered for primary slots in Orbit 60 Series chassis.

It converts incoming external DC utility power into regulated internal distribution, ensuring continuous continuous power supply to backplane buses and signal processing modules.

This module is strictly designed for 3U chassis designs and requires proper utility-side grounding on its dedicated terminal block during installation.

The Bently Nevada 60R/PIM01-02-0 Power Input Module is fully guaranteed and backed by the manufacturer (OEM).
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Providing regulated power input to Orbit 60 protection chassis on critical industrial turbomachinery.
  • Delivering uninterrupted redundant power for continuous vibration and condition monitoring systems.
  • Supplying system power across hazardous oil and gas, power generation, and petrochemical facilities.
  • Consumes a typical 120 W with a maximum system load rating of 180 W in 3U chassis setups.
  • Draws a nominal 7.1 Amps at 24 Vdc input with a maximum current capacity of 8.6 Amps.
  • Delivers regulated DC power distribution to internal system backplanes with minimal conversion loss.
  • Designed for seamless integration with external DIN-rail mounted industrial AC/DC power supply units.
  • Operates natively alongside dynamic measurement, condition monitoring, and relay modules in Orbit 60 systems.
  • Serves as a half-height module strictly compatible with 3U chassis and non-interchangeable with 6U full-height units.
  • Supports remote internal module firmware flashing through Orbit 60 System Interface Module connections.
  • Maintains hardware configuration metadata and module identity info within internal non-volatile memory.
  • Enables online firmware verifications and diagnostic health status queries via System Configuration Software.
Description
Bently Nevada 60R/PIM01-02-0 Power Input Module is a specialized power interface component designed exclusively for 3U chassis configurations within the Orbit 60 Series machinery protection platform. Occupying the primary dedicated slot of the chassis, this half-height module receives external direct current power ranging from +21 Vdc to +32 Vdc, typically supplied by external DIN-rail mounted AC/DC power units. Deploying dual 60R/PIM01-02-0 modules enables complete power redundancy, ensuring uninterrupted power delivery to backplane electronics and dynamic monitoring modules.

Engineered to safeguard internal system electronics from external power line disturbances, the 60R/PIM01-02-0 incorporates comprehensive out-of-range electrical protection. Undervoltage events cause no harm to internal circuitry, while overvoltage or miswiring conditions safely open a built-in, field-replaceable fuse to prevent downstream damage. Support for online insertion and removal allows plant maintenance personnel to hot-swap a single power module without shutting down the monitoring chassis or interrupting continuous machinery protections.

Built for demanding industrial environments, the 60R/PIM01-02-0 features multi-agency certifications including CSA Class I Division 2, ATEX, and IECEx Zone 2 ratings across an extended operating temperature range of -30°C to +70°C. The module also serves as the single physical connection point for system Instrument Common (I.S.) and Protective Earth (P.E.) grounds on its utility side connectors, effectively eliminating ground loops and noise interference across plant-wide monitoring networks.
Alternative Names
60R-PIM01-02-0 60RPIM01020 60R/PIM01 02 0 60R PIM 01 02 0 Bently Nevada 60R/PIM01-02-0 Bently Nevada 60R/PIM01 Bently Nevada Orbit 60 3U Power Input Module
Technical notes
The Bently Nevada 60R/PIM01-02-0 is a half-height module specifically designed for 3U Orbit 60 chassis and is not interchangeable with 6U full-height PIM modules.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Is there a minimum load requirement for the Bently Nevada 60R/PIM01-02-0?
No minimum chassis load is required for the Bently Nevada 60R/PIM01-02-0 to operate.  
How does the Bently Nevada 60R/PIM01-02-0 respond to input voltage faults?
The Bently Nevada 60R/PIM01-02-0 is non-damaging under undervoltage conditions and opens an internal replaceable fuse during overvoltage conditions.  
Can the Bently Nevada 60R/PIM01-02-0 be used in a 6U Orbit 60 chassis?
No, the 60R/PIM01-02-0 is a half-height module dedicated to 3U chassis designs; 6U chassis require full-height 60R/PIM02 series modules.  
What does the LED indicator on the Bently Nevada 60R/PIM01-02-0 signal?
The front panel "Power OK" LED illuminates green when input power to the Bently Nevada 60R/PIM01-02-0 is within acceptable limits.  
Where are system ground connections made on the Bently Nevada 60R/PIM01-02-0?
Instrument Common (I.S.) and Protective Earth (P.E.) ground connections are located on the utility side terminal block of the Bently Nevada 60R/PIM01-02-0.  
How can I purchase or request a quotation for the Bently Nevada 60R/PIM01-02-0?
You can request price quotes, lead time, and technical support for the Bently Nevada 60R/PIM01-02-0 by contacting our technical sales team.

Product Browsing History