Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle Status

    Active / Available from OEM
    Apter Power provides immediate official quotes, procurement support, and system integration guidance for this module.

60R/INP06-02-0

/ 4.9
1001 reviews | Need a Specific Revision?
The Bently Nevada 60R/INP06-02-0 is a single-slot Keyphasor Input Module engineered for the Orbit 60 Series Machinery Protection and Condition Monitoring System.
In Stock
Ships by Tuesday, October 27
Fast Shipping Available
Get a quick price for 60R/INP06-02-0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 60R/INP06-02-0

  • Manufacturer:
    Bently Nevada
  • Part Number:
    60R/INP06-02-0
  • Product Family:
    Orbit 60 Series
  • Product Type:
    Keyphasor Input Module
  • Stock:
    1
  • Hazardous Area Certifications:
    Multi (CSA, ATEX, IECEx)
  • Functional Safety Level:
    No SIL
  • Number of Channels:
    4 input channels per single-slot module
  • Speed/Frequency Signal Range:
    1 to 120,000 cpm (0.017 Hz to 2 kHz)
  • Input Speed Limit:
    120,000 rpm; accepts input speed signals up to 1,200,000 cpm (20 kHz)
  • Transducer Support:
    Magnetic pickup, 3-wire Proximitor, and 3-wire Accelerometer
  • Transducer Power Supply:
    -24 Vdc, 40 mA maximum per channel
  • Power Consumption:
    3 W typical, 6 W maximum
  • Buffered Transducer Output (BTO):
    Female Type A "ix" connector available on public and utility side; 500 Ω output impedance
  • BTO Signal Type:
    Configurable via Orbit Studio as true analog or conditioned digital TTL (5V/3.3V) signal
  • Physical Space Required:
    1 slot in standard Orbit 60 chassis
  • Operating Temperature Range:
    -30°C to +70°C (-22°F to +158°F)
  • LED Status Indicators:
    Module OK LED, LINK LED, and Channel Status LEDs (1 per channel)
  • Estimated shipping dimensions:
    2.03 x 5.2 x 24.56 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Interoperability Environmental Ratings Communication & Connectivity

Features:

  • Provides 4 dynamic speed input channels supporting magnetic pickups and 3-wire sensors up to 120,000 rpm.
  • Features multi-agency hazardous area approvals including CSA, ATEX, and IECEx Zone 2 / Division 2.
  • Equipped with 2-wire galvanically isolated inputs to prevent electrical ground loops across speed channels.
Part number 60R/INP06-02-0 designates the standard non-SIL Keyphasor Input Module with multi-certified hazardous location ratings for the Orbit 60 monitoring platform.

The module conditions once-per-turn or multi-event speed signals to provide critical phase timing, keyphasor triggers, and synchronous tracking for machinery protection.

Designed for single-slot installation in Orbit 60 chassis, it requires proper sensor power configuration via software and routing speed signals away from vibration lines in ETB cables.

The Bently Nevada Orbit 60 60R/INP06-02-0 Keyphasor Input Module availability is supported by the manufacturer (OEM).
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Precision phase timing reference generation for 1X and 2X synchronous shaft vibration tracking on turbomachinery trains.
  • Rotational speed measurement and multi-event wheel crank angle tracking for industrial reciprocating compressors.
  • Backup speed reference switching for continuous phase tracking on critical rotating equipment in petrochemical facilities.
  • Operates across Orbit 60 standard 3U, 6U, and distributed chassis architectures via Bridge module interconnections.
  • Interfaces directly with 2-wire magnetic speed pickups, 3-wire Proximitor sensors, and 3-wire accelerometers.
  • Provides synchronous phase reference timing to PAV, PAS, PAA, PAD, and PVT dynamic input modules across the system.
  • Meets IP20 ingress protection rating standards for industrial control cabinet and rack installations.
  • Designed for Pollution Degree 2 environments under standard IEC industrial installation conditions.
  • Conforms to IEC 60068-2-6 and IEC 60068-2-27 standards for continuous industrial shock and vibration resistance.
  • Transmits high-speed digitized phase and speed data across the Orbit 60 backplane at a 102.4 kHz sampling rate.
  • Interconnects seamlessly across multiple distributed chassis via Bridge modules to reduce field wiring overhead.
  • Routes processed timing reference signals directly to System Interface Modules for plant control system integration.
Description
Bently Nevada 60R/INP06-02-0 is an advanced 4-channel speed and timing input module designed specifically for high-accuracy rotational phase angle and speed measurement in the Orbit 60 monitoring platform. Occupying a single chassis slot, this module provides key timing triggers necessary for synchronous sampling, vector filtering, 1X/2X vibration tracking, and phase measurements on rotating industrial machinery.

Operating within critical machinery protection networks, the Bently Nevada 60R/INP06-02-0 module accepts inputs from magnetic pickups, 3-wire proximity probes, and 3-wire accelerometers across a broad speed range up to 120,000 rpm. The module provides individual buffered transducer outputs for each channel, selectable as unconditioned analog pass-through or processed TTL digital signals, while offering specialized capabilities such as backup speed source switching and reciprocating multi-event wheel tracking.

The Bently Nevada 60R/INP06-02-0 configuration features comprehensive Multi-agency hazardous area approvals including CSA, ATEX, and IECEx for Class I, Division 2 and Zone 2 installations. With its robust galvanic isolation on 2-wire magnetic pickup lines and low power consumption profile, it integrates seamlessly into Orbit 60 3U or 6U chassis to maintain operational safety in demanding power generation, oil and gas, and petrochemical process environments.
Alternative Names
60R/INP06-02-0 60R/INP06-02-O 60R-INP06-02-0 60RINP06020 60R INP06020 Bently Nevada 60R/INP06-02-0 Orbit 60 Speed Input Module 60R/INP06-02-0 Bently Nevada Orbit 60 Keyphasor Module 60R/INP06-02-0
Technical notes
The Bently Nevada 60R/INP06-02-0 module features a 2-wire galvanically isolated high-impedance input structure that prevents ground loops when sharing magnetic pickup speed sensors with external instrumentation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How many physical chassis slots does the Bently Nevada 60R/INP06-02-0 require?
The Bently Nevada 60R/INP06-02-0 occupies a single slot in an Orbit 60 Series 3U or 6U chassis.
Can the Bently Nevada 60R/INP06-02-0 be configured to provide a digital TTL speed output?
Yes, through Orbit Studio software, each buffered output on the Bently Nevada 60R/INP06-02-0 can be configured as a true analog signal or a processed 5V/3.3V TTL digital signal.
Which sensor types can be connected to the Bently Nevada 60R/INP06-02-0?
The Bently Nevada 60R/INP06-02-0 accepts 2-wire magnetic pickups, 3-wire Proximitor sensors, and 3-wire accelerometers.
What type of Buffered Transducer Output (BTO) connector is used on the Bently Nevada 60R/INP06-02-0?
The Bently Nevada 60R/INP06-02-0 uses female Type A "ix" connectors on both the public and utility sides for buffered transducer output access.
Does the Bently Nevada 60R/INP06-02-0 support backup speed source switching?
es, the Bently Nevada 60R/INP06-02-0 can be configured with a backup speed channel that automatically takes over if the primary speed channel enters an invalid state.
How can I request a price quote or check availability for the Bently Nevada 60R/INP06-02-0?
You can submit a direct RFQ (Request for Quote) or contact our sales and support team with the full part number Bently Nevada 60R/INP06-02-0 to receive immediate stock status, pricing, and shipping details.

Product Browsing History