Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports software quotation, release review, and configuration-workflow guidance.

60X/CFG

/ 4.9
1001 reviews | Need a Specific Revision?
Bently Nevada 60X/CFG is Orbit Studio Configuration Software for configuring, verifying and maintaining Orbit 60 chassis, modules, channels, measurements, alarms and relay logic.
In Stock
Ships by Tuesday, October 27
Fast Shipping Available
Get a quick price for 60X/CFG
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 60X/CFG

  • Manufacturer:
    Bently Nevada
  • Part Number:
    60X/CFG
  • Product Family:
    Orbit 60 Series
  • Product Type:
    Configuration Software
  • Stock:
    1
  • Part number:
    60X/CFG
  • Software name:
    Orbit Studio Configuration Software
  • System family:
    Orbit 60 Series
  • Configuration scope:
    Chassis, modules, channels, measurements and setpoints
  • Relay logic modes:
    Graphical and text-based
  • Multi-system session:
    Supported
  • Offline file comparison:
    Supported
  • Send and retrieve configuration:
    Supported for multiple systems
  • Capacity tool:
    System Utilization Calculator
  • PPM warning threshold:
    90% utilization
  • Verification displays:
    Bar graphs and tabular current-value lists
  • Hardware access path:
    Orbit 60 System Interface Module
  • Security control:
    User-based permissions and SIM physical access controls
  • Reference guide:
    Orbit Studio Configuration Software User Guide 137M0696
  • Tariff Code:
    Please confirm the destination before shipping.
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Configuration Monitoring Communication

Features:

  • Configures Orbit 60 chassis, modules, channels, measurements, alarms and relay functions.
  • Supports simultaneous work with online systems and offline configuration files in one client session.
  • Provides system-capacity, current-value and loop-check tools for engineering verification.
The current ordering identity is 60X/CFG, the Orbit Studio Configuration Software item listed for the Orbit 60 platform.

Engineers use it to create protection measurements, manage setpoints, assemble relay logic and send or retrieve configurations through the System Interface Module.

Before applying a project, confirm software compatibility, user permissions, system identity, channel scaling and the accuracy impact of any custom transducer or filtering choice.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Bently Nevada 60X/CFG: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Builds and reviews machinery-protection configurations for new Orbit 60 chassis before commissioning.
  • Supports maintenance by comparing offline files with connected systems and retrieving controlled configuration records.
  • Guides loop checks with live measurement, health, alarm and time information from channels across the system.
  • Create chassis, module, channel, measurement and setpoint definitions within one coordinated Orbit 60 engineering project.
  • Open connected systems beside offline files to compare configurations and copy approved modules or channels between controlled projects.
  • Apply user permissions before sending or retrieving configurations so access remains aligned with the site change-management process.
  • Current-value views combine measurement results, channel health, alarm severity and system time for commissioning review.
  • Loop-check screens display channel data in bar graphs and tables so multiple field paths can be verified consistently.
  • The System Utilization Calculator warns when protection-processing capacity reaches 90 percent and additional PPM resources should be considered.
  • Orbit Studio reaches the protection system through the System Interface Module, which distributes configuration data to other modules.
  • Three independently configurable SIM Ethernet ports can support configuration, time synchronization, temporary troubleshooting or an external display.
  • A single client session can connect to multiple Orbit 60 systems while maintaining separate identities, permissions and configuration records.
Description
Bently Nevada 60X/CFG is the Orbit Studio Configuration Software item used to build and maintain Orbit 60 chassis, module, channel, measurement, setpoint and relay configurations. It supplies the engineering workspace for protection-system design, revision control and commissioning preparation rather than performing a field-mounted sensing or switching function. The same environment presents the configured hardware hierarchy and its dependent measurement logic in one project.

A single client session can open connected systems and offline configuration files together, allowing engineers to compare arrangements, copy approved modules or channels and coordinate configuration transfers between controlled projects. Current-value, alarm-health and loop-check views support commissioning analysis, while the System Utilization Calculator helps the project team assess whether protection-processing capacity remains suitable as measurements and logic are added.

Communication with installed hardware is routed through the System Interface Module and remains subject to the physical access controls and user permissions applied at the site. Before sending a project, confirm software-release compatibility, system identity, channel scaling, alarm intent and the approved change record. Custom transducer ranges or nonstandard filters require an installed end-to-end test because unsuitable selections can reduce measurement accuracy or make noise response more sensitive.
Alternative Names
60X/CFG 60X CFG 60XCFG Bently Nevada 60X/CFG Bently Nevada Orbit Studio 60X/CFG 60X/CFG Orbit 60 Configuration Software Baker Hughes 60X/CFG Orbit Studio
Technical notes
60X/CFG custom transducer ranges and filters can reduce measurement accuracy; validate the final Orbit 60 setup with installed end-to-end testing.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which Orbit 60 objects can 60X/CFG configure?
The software manages chassis hardware, modules, channels, measurements, alarm setpoints, relay logic and other protection-system settings.
How does 60X/CFG connect to a live protection system?
Orbit Studio communicates through the System Interface Module, whose key switch or contact can prevent unauthorized configuration changes.
When is the multi-system workspace in 60X/CFG useful?
It allows connected systems and offline files to remain open together for comparison, copying and coordinated configuration transfer.
What commercial details are confirmed for a 60X/CFG request?
Apter Power checks the exact software reference, delivery form, release requirement, quantity and destination before quotation.
Why must a migrated 60X/CFG project receive a loop check?
Custom ranges, filtering and copied channel settings can affect accuracy, so installed end-to-end verification remains necessary.
Which file set should accompany a 60X/CFG engineering inquiry?
Provide the current Orbit Studio release, saved project, module inventory, channel list, permission requirements and target system version.

Product Browsing History