Features:
- Complete order identity: The code covers the M-series output card and its matching mass-termination hardware.
- Concentrated output role: The assembly groups the documented field-output function into one cabinet position.
- Platform-specific architecture: The M-series carrier and termination relationship defines the installation boundary.
The complete code helps receiving teams distinguish a full output assembly from a card-only item, reducing scope ambiguity when a spare is ordered.
Its channel concentration supports existing cabinets that allocate many discrete field outputs to one M-series position, preserving the project's established output grouping during maintenance.
The carrier and mass-termination arrangement remain the decisive fit boundary; electrical similarity to an S-series order is not evidence of mechanical interchangeability.
Emerson CE4002S1T2B6 DeltaV M-Series 32-Channel High-Side Output with 40-Pin Termination may be sourced with documentation and quotation support from Apter Power.
Emerson CE4002S1T2B6 DeltaV M-Series 32-Channel High-Side Output with 40-Pin Termination Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- M-series identity: CE4002S1T2B6 is listed in the DeltaV M-series Traditional I/O ordering table, making the platform part of the selection boundary.
- Installed carrier: Use the order only where the cabinet position is built for the documented M-series architecture.
- Series separation: The SE code with the same numeric core belongs to S-series and does not establish fit for this CE assembly.
- Stop boundary: Pause the changeout when the carrier label or mechanical interface differs from the M-series arrangement.
- Mass termination: The documented order includes a 40-pin mass I/O termination block, so the cabinet connection must follow that architecture.
- Channel ownership: Reconcile the existing 32-output allocation with the approved project drawing before moving field conductors.
- Field circuit: Retain the documented 24 V DC high-side output basis when reviewing the load and supply design.
- Wiring boundary: Stop when the installed terminal interface or pin assignment cannot be matched to the approved mass-termination drawing.
- Point mapping: Compare the project database with the installed channel assignments before returning outputs to service.
- Output direction: Treat the assembly as a high-side discrete output device rather than reusing an input-module checkout procedure.
- Controlled energization: Restore the field circuit only after the approved channel and termination checks are complete.
- Functional acceptance: Prove each commanded output against its intended field point before release to operations.
- DeltaV M-series output service: Use CE4002S1T2B6 where the project specifies this complete M-series discrete output order.
- Mass-terminated cabinets: Apply the assembly in cabinet designs built around the documented 40-pin termination architecture.
- High-density field outputs: The configuration serves projects that assign 32 high-side output points to one M-series assembly.
- Exact-code spare planning: Keep the complete CE identity when stocking a replacement for an installed cabinet position.