Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power matches the full KJ2003X1-BB1 12P3439X022 VE3006 identity, controller carrier and DeltaV configuration before quotation.

KJ2003X1-BB1 12P3439X022 VE3006

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson KJ2003X1-BB1 12P3439X022 VE3006 is a DeltaV M-series MD Plus controller identified by order code 12P3439X022 for process-control execution.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for KJ2003X1-BB1 12P3439X022 VE3006
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for KJ2003X1-BB1 12P3439X022 VE3006

  • Manufacturer:
    Emerson
  • Part Number:
    KJ2003X1-BB1 12P3439X022 VE3006
  • Product Family:
    DeltaV
  • Product Type:
    DeltaV M-series MD Plus Controller
  • Stock:
    1
  • System role:
    Communication and control between field devices and control-network nodes
  • Control network:
    Full-duplex Ethernet; up to 100 MB/s
  • Controller setup:
    Self-addressing, self-locating, and automatic I/O detection
  • Configuration retention:
    Online changes stored automatically; autonomous cold restart from nonvolatile memory
  • Redundancy:
    1:1 online redundancy supported
  • Input power:
    +5 V DC at 1.4 A
  • Ambient temperature:
    −40 to +70 °C
  • Relative humidity:
    5–95% noncondensing
  • Airborne contaminants:
    ISA-S71.04 Class G3
  • Shock:
    10 g half-sine wave for 11 ms
  • Vibration:
    1 mm peak-to-peak from 5–16 Hz; 0.5 g from 16–150 Hz
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Order Identity Recovery Service Limits Applications

Features:

  • 12P3439X022 article identity
  • DeltaV M-series MD Plus controller role
  • Full-duplex Ethernet control-network communication

KJ2003X1-BB1 12P3439X022 VE3006 keeps the VE3006 and KJ2003X1-BB1 identities tied to one exact article number.


Automatic I/O detection and nonvolatile configuration storage support controller recovery within the installed M-series architecture.


Redundant service depends on the correct carrier, power, network and saved DeltaV configuration.

For KJ2003X1-BB1 12P3439X022 VE3006 identity review, configuration matching and quotation support, contact Apter Power.
Emerson KJ2003X1-BB1 12P3439X022 VE3006 DeltaV M-series MD Plus Controller Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Order article: 12P3439X022 identifies this controller assembly
  • Hardware code: KJ2003X1-BB1 remains part of the complete identity
  • Order model: VE3006 identifies the MD Plus controller role
  • Selection boundary: Use the complete string rather than either shared code alone
  • Storage: Online changes are retained in nonvolatile memory
  • Cold restart: Autonomous recovery uses the stored controller database
  • I/O discovery: Assigned I/O is detected automatically
  • Redundancy: Optional 1:1 online controller redundancy is supported
  • Input power: +5 VDC at 1.4 A from the controller carrier
  • Temperature: -40 to 70 °C operating range
  • Humidity: 5-95% relative humidity, noncondensing
  • Contaminants: ISA-S71.04 Class G3 airborne-contaminant environment
  • Process control: Execution of DeltaV control modules
  • M-series cabinets: Controller service in installed DeltaV M-series carriers
  • Network control: Communication between controller and assigned field I/O
  • Redundant nodes: Optional 1:1 online redundancy in a supported architecture
Description
Emerson KJ2003X1-BB1 12P3439X022 VE3006 combines the VE3006 order identity with KJ2003X1-BB1 controller hardware for DeltaV M-series MD Plus service. Keeping the 12P3439X022 article number in the order record distinguishes this assembly from the X032 article and prevents a quotation based only on the shared controller code.

Emerson KJ2003X1-BB1 12P3439X022 VE3006 uses full-duplex Ethernet for DeltaV control-network communication, detects assigned I/O automatically, and stores online changes in nonvolatile memory for autonomous cold restart. These functions allow a service replacement to recover its approved node role without rebuilding the controller database from scratch.

Optional 1:1 online redundancy on Emerson KJ2003X1-BB1 12P3439X022 VE3006 depends on the intended carrier, power and network arrangement. Match the complete label, DeltaV software baseline and redundancy design before commissioning so the active and standby nodes enter service with the correct assembly identity.
Alternative Names
12P3439X022 MD Plus Controller DeltaV M-series MD Plus Controller KJ2003X1BB1 KJ2003X1 BB1 Emerson VE3006 Emerson KJ2003X1-BB1 DeltaV MD Plus Controller VE3006
Technical notes
KJ2003X1-BB1 12P3439X022 VE3006 requires +5 VDC at 1.4 A through its M-series controller carrier. Insufficient carrier power can prevent recognition or interrupt control execution, so verify the installed power arrangement and stop commissioning if the controller and assigned I/O do not return together after the approved database is restored.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can I distinguish KJ2003X1-BB1 12P3439X022 VE3006 from another VE3006 controller?
Use 12P3439X022 together with KJ2003X1-BB1 and VE3006. The shared VE3006 or KJ code alone does not identify this article for purchasing.
Can KJ2003X1-BB1 12P3439X022 VE3006 operate as part of a redundant controller pair?
Yes. The MD Plus platform supports optional 1:1 online redundancy when the compatible carrier, power, network paths and DeltaV configuration are present.
What happens to KJ2003X1-BB1 12P3439X022 VE3006 after controller power is restored?
Its nonvolatile memory retains online changes and supports the documented autonomous cold restart. Release control only after the saved database and assigned I/O are recognized.
Which control-network connection is used by KJ2003X1-BB1 12P3439X022 VE3006?
The controller uses full-duplex Ethernet on the DeltaV control network. In a redundant design, confirm both network paths before returning the node to process service.
How does automatic I/O detection affect a replacement of KJ2003X1-BB1 12P3439X022 VE3006?
The controller can locate assigned I/O automatically, but the restored database and node identity must still match the installed system. Stop if ownership differs from the approved configuration.
What environment should be provided for KJ2003X1-BB1 12P3439X022 VE3006?
Use the specified -40 to 70 °C range, 5-95% noncondensing humidity and ISA-S71.04 Class G3 contaminant environment as the cabinet limits.
What information should an RFQ for KJ2003X1-BB1 12P3439X022 VE3006 include?
Provide the complete model, installed DeltaV release, carrier and power arrangement, network design, redundancy requirement and requested test scope.