Features:
- Executes safety logic for emergency shutdown and process protection.
- -40°C to +70°C, 10g shock, ISA G3, 5-95% humidity.
- Ex ec IIC Gc, ATEX, and Class I Div 2/Zone 2 approvals.
The KJ2201X1-BA1 12P3162X182 SLS1508 is a SIS (Safety Instrumented System) Logic Solver module designed for the Emerson DeltaV scalable process control system. This module executes critical safety logic for emergency shutdown (ESD), fire and gas (F&G), and burner management systems (BMS) applications. The KJ2201X1-BA1 12P3162X182 SLS1508 operates on 24V LocalBus power at 1A and supports field power up to 4A, ensuring reliable power delivery for safety-critical functions.
The KJ2201X1-BA1 12P3162X182 SLS1508 is engineered for reliable operation in harsh industrial environments. It operates over an extreme temperature range of -40°C to +70°C and can withstand shock of 10g half-sine for 11ms. The KJ2201X1-BA1 12P3162X182 SLS1508 features vibration resistance of 1mm peak-to-peak from 2 to 13.2Hz and 0.7g from 13.2 to 150Hz. The KJ2201X1-BA1 12P3162X182 SLS1508 complies with ISA-S71.04-1985 Class G3 airborne contaminants and operates with 5-95% non-condensing relative humidity.
The KJ2201X1-BA1 12P3162X182 SLS1508 carries multiple hazardous area approvals including II 3G Ex ec IIC Gc, FM16ATEX0056U, and FM21UKEX0017U certifications. The KJ2201X1-BA1 12P3162X182 SLS1508 also holds CL.I Div.2 GP.A,B,C,D and CL.I Zone 2 AEx/Ex ec IIC Gc certifications, making it suitable for installation in potentially explosive atmospheres. The KJ2201X1-BA1 12P3162X182 SLS1508 requires field power to be removed before connecting or removing the device, and contains no user-serviceable parts.
The KJ2201X1-BA1 12P3162X182 SLS1508 EMERSON SIS Logic Solver may still be available for purchase and support from Apter Power beyond
End-Of-Life (EOL) by the manufacturer (OEM).
EMERSON KJ2201X1-BA1 12P3162X182 SLS1508 SIS Logic Solver Manuals, Datasheets, Drivers, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Specifications
EMERSON KJ2201X1-BA1 12P3162X182 SLS1508 SIS Logic Solver Specs
General
- Manufacturer EMERSON
- Model KJ2201X1-BA1 12P3162X182 SLS1508
- Condition New Original ready stock
- Product Family
KJ2201X1-BA1 12P3162X162 SLS1508,KJ2201X1-BA1 12P3162X212 SLS1508
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not
included with this equipment unless listed in the above stock item description. All prices are
shown in USD.
- Upstream/Midstream Oil & Gas: Deployed on offshore platforms, subsea manifolds, and pipeline compressor stations to prevent fluid spills or high-pressure breaches.
- Refining & Petrochemical Processing: Monitors continuous hydrocarbon reactions, protecting complex units like hydrocrackers and distillation towers.
- Chemical Reaction Plants: Safeguards exothermic reactor vessels and handles emergencies associated with volatile gas blending.
- Power Utilities: Built into safety instrumentation loops for high-temperature boilers, furnace operations, and steam management systems.
- ATEX / UKEX: Rated II 3G Ex ec IIC Gc (Zone 2 protection).
- North America: FM approved for Class I, Division 2, Groups A, B, C, D and Class I, Zone 2 AEx/Ex ec IIC Gc environments.
- ISA-S71.04 Class G3: Certified for harsh airborne contaminant exposure (harsh corrosive environments).
- Mechanical Resilience: Tested to withstand 10g half-sinewave shocks (11ms duration) and vibrations up to 150Hz.
- DeltaV Platform Integration: Fully compatible with Emerson DeltaV Engineering Tools (DeltaV v8.3 software or later). It allows complete drag-and-drop programming, safety loop strategy tracking, and automatic tracking via a dedicated Device Audit Trail.
- Intelligent HART Communication: Functions as a smart solver by actively using the HART protocol to communicate with field transmitters. It diagnoses field instrumentation and final valve faults before they can trigger accidental process trips.
- Independent safety peer network (SISnet): Connects to neighboring logic solvers via a dedicated, redundant, localized two-channel SISnet peer bus. This network operates separately from the standard control bus, ensuring that process automation congestion never delays emergency commands.