Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Active / Available from OEM

    Apter Power supports exact terminal-block identification, documentation review, and installation-reference matching.

KJ3241X1-EA1

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson KJ3241X1-EA1 is identified in the official ATEX instruction sheet as a DeltaV Red Interface Terminal Block for Electronic Marshalling hardware.
In Stock
Fast Shipping Available
Get a quick price for KJ3241X1-EA1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for KJ3241X1-EA1

  • Manufacturer:
    Emerson
  • Part Number:
    KJ3241X1-EA1
  • Product Family:
    DeltaV
  • Product Type:
    Red Interface Terminal Block
  • Stock:
    1
  • Product Designation:
    Red Interface Terminal Block
  • Input Power Rating:
    35 VDC at 1 A
  • Operating Temperature:
    -40 to +70°C
  • Relative Humidity:
    5 to 95%, non-condensing
  • Airborne Contaminants:
    ISA-S71.04-1985, Class G3
  • Shock:
    10 g half-sine wave for 11 ms
  • Vibration:
    1 mm peak-to-peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz
  • Hazardous-Area Marking:
    II 3G Ex ec IIC Gc
  • Country of Origin:
    USA
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Input Power Zone 2 Handling Maintenance Limits

Features:

  • Product designation: Red Interface Terminal Block
  • Input rating: 35 VDC at 1 A
  • Installation context: DeltaV Electronic Marshalling hardware
This ordering configuration is the KJ3241X1-EA1 DeltaV Red Interface Terminal Block identified by Emerson instruction sheet ATEX249.

It is documented for DeltaV Electronic Marshalling hardware and for the environmental and hazardous-area limits stated on the product instruction sheet.

Remove system power before insertion or removal, then confirm the complete EA1 label and applicable installation instructions before service.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson KJ3241X1-EA1:
  • Terminal-block replacement where the installed DeltaV hardware label identifies KJ3241X1-EA1.
  • Electronic Marshalling projects that require the Red Interface Terminal Block named in ATEX249.
  • Hazardous-area installations engineered to the model-specific approval markings and Zone 2 instructions.
  • Supply the terminal block from a 35 VDC source within the documented 1 A rating.
  • Verify polarity and the complete EA1 hardware identity before energizing the circuit.
  • Coordinate the power source with the Electronic Marshalling installation documentation.
  • Apply the model-specific II 3G Ex ec IIC Gc marking to the area-classification review.
  • Use the referenced DeltaV Electronic Marshalling Zone 2 instructions for installation and operation.
  • De-energize system power before the unit is inserted or removed.
  • Do not disassemble the unit because it contains no user-serviceable parts.
  • No calibration procedure is required for the terminal block.
  • Use the product label to verify serial number and manufacturing-location information.
Description
KJ3241X1-EA1 is the Emerson DeltaV Red Interface Terminal Block identified by the official ATEX249 instruction sheet.

The hardware is documented for DeltaV Electronic Marshalling installations and carries a 35 VDC at 1 A input power rating. Its environmental limits cover -40 to +70°C operation and 5 to 95% non-condensing relative humidity.

Remove system power before inserting or removing the unit. Match the complete EA1 suffix, product label, hazardous-area approval, and installation instructions before replacement.
Alternative Names
KJ3241X1-EA1 KJ3241X1 EA1 DeltaV Red Interface Terminal Block
Technical notes
KJ3241X1-EA1 is the Red Interface Terminal Block covered by Emerson instruction sheet ATEX249. It has no user-serviceable parts and requires no calibration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What input rating applies to KJ3241X1-EA1?
The documented input power rating is 35 VDC at 1 A.
Can this terminal block be inserted with system power on?
No. Emerson requires system power to be de-energized before insertion or removal.
Does KJ3241X1-EA1 require calibration?
No. The official instruction sheet states that calibration is not required.
Are there serviceable components inside the unit?
No. It contains no user-serviceable parts and should not be disassembled.
Which humidity range is specified for this model?
The specified range is 5 to 95% relative humidity, non-condensing.
What must be matched before replacement?
Confirm the EA1 suffix, product label, approval marking, and the applicable DeltaV installation instructions.