Features:
- The KJ4006X1-BT1 specification lists terminal role as Redundant analog output termination for the DeltaV S-series Traditional I/O configuration.
- The documented redundancy for KJ4006X1-BT1 is redundant I/O card pair within its DeltaV S-series Traditional I/O system role.
- KJ4006X1-BT1's documented ordering code is KJ4006X1-BT1 in the DeltaV S-series Redundant Analog Output Terminal Block configuration.
The current ordering configuration is KJ4006X1-BT1, the DeltaV S-series Redundant Analog Output Terminal Block identified for the DeltaV S-series Traditional I/O.
KJ4006X1-BT1 performs its documented system role within the DeltaV S-series Traditional I/O architecture. The application and operating limits remain those assigned to this exact ordering configuration.
Before commissioning, match the supported AO cards, verify loop load and polarity, test output transfer after installation.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson KJ4006X1-BT1:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Terminate two analog output cards in a redundant eight-channel 4-20 mA HART output assembly.
- Connect redundant current-output loops for compatible control valves and other supported final-control devices.
- Provide the field-side wiring interface required for transfer between the paired S-series analog output cards.
- The KJ4006X1-BT1 specification lists terminal role as Redundant analog output termination for the DeltaV S-series Traditional I/O configuration.
- The documented signal family for KJ4006X1-BT1 is 4-20 mA HART analog output within its DeltaV S-series Traditional I/O system role.
- KJ4006X1-BT1's documented redundancy is redundant I/O card pair in the DeltaV S-series Redundant Analog Output Terminal Block configuration.
- The KJ4006X1-BT1 specification lists series as DeltaV S-series for the DeltaV S-series Traditional I/O configuration.
- The documented ordering code for KJ4006X1-BT1 is KJ4006X1-BT1 within its DeltaV S-series Traditional I/O system role.
- KJ4006X1-BT1's documented field connection is analog output loop termination in the DeltaV S-series Redundant Analog Output Terminal Block configuration.
- The KJ4006X1-BT1 specification lists operating temperature as -40 to 70 degrees C for the DeltaV S-series Traditional I/O configuration.
- The documented storage temperature for KJ4006X1-BT1 is -40 to 85 degrees C within its DeltaV S-series Traditional I/O system role.
- For KJ4006X1-BT1, test output transfer after installation for the documented KJ4006X1-BT1 DeltaV S-series Traditional I/O configuration.