Features:
- Direct high-side switching: Applies the positive 24 VDC path to a compatible field load under DeltaV control.
- Selectable output behavior: Supports momentary and pulse duties when they are defined in the channel configuration.
- Useful fault context: Published load bands help distinguish a healthy circuit from short or open conditions.
KL3002X1-BA1 is the 24 VDC high-side output CHARM product type named in Emerson installation documentation.
It gives one DeltaV channel a local switching path for a compatible DC load, with configured behavior and line-fault information available to the control strategy.
The useful service boundary includes the CHARM, terminal block, field source, wiring and load, so successful card recognition is only one part of output acceptance.
Apter Power can help confirm the terminal, load and channel fit for the Emerson KL3002X1-BA1 DeltaV 24 VDC High-Side Discrete Output CHARM before quotation.
Emerson KL3002X1-BA1 DeltaV 24 VDC High-Side Discrete Output CHARM Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Positive-side switching: The channel controls delivery of the 24 VDC source to the connected load.
- Defined load duty: Continuous current stays within the published output capability.
- Field destination: The configured DeltaV point and physical conductor must reach the intended solenoid, relay or input.
- Return reference: The load return path remains part of the complete working circuit.
- Momentary action: A timed command can operate devices that should not remain energized.
- Continuous pulse: Repeating output behavior is used only when the field device and logic require it.
- Load interpretation: Short, good and open bands provide diagnostic context rather than a substitute for measurement.
- Protective response: Current limiting and field disconnect help contain an abnormal load condition.
- Product-type mapping: The exact hardware code is tied to the high-side DO CHARM identity before procurement.
- Terminal relationship: The installed terminal-block type is captured with the channel wiring.
- Command trace: DeltaV state, terminal voltage and physical load movement are tested in sequence.
- Sequence release: Interlocks and automatic steps are returned only after the correct destination responds.
- Small solenoid control: Switches compatible 24 VDC coils within the published load capability.
- Interposing relay drive: Operates a documented relay interface for larger or isolated downstream circuits.
- Package-unit commands: Sends discrete run, enable or reset signals to supported equipment interfaces.
- Brownfield channel repair: Restores an identified high-side CHARM point while verified wiring is retained.