Emerson PR6423/009-031 CON041
Emerson PR6423/009-031 CON041
Emerson PR6423/009-031 CON041
Emerson PR6423/009-031 CON041
Emerson PR6423/009-031 CON041
Emerson PR6423/009-031 CON041
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, technical documents, procurement and system matching.

PR6423/009-031 CON041

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson PR6423/009-031 CON041 pairs a long M10×1 8 mm sensor with 8 m open lead and DIN-rail converter.
In Stock
Ships by Tuesday, November 10
Fast Shipping Available
Get a quick price for PR6423/009-031 CON041
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PR6423/009-031 CON041

  • Manufacturer:
    Emerson
  • Part Number:
    PR6423/009-031 CON041
  • Product Family:
    Epro
  • Product Type:
    8 mm Eddy Current Sensor with CON041 Converter
  • Stock:
    1
  • Sensor thread:
    M10×1
  • Sensor body:
    Cx 115 mm; total C 124 mm
  • Armored cable:
    Without armor
  • Adapter plug:
    With adapter
  • Total cable length:
    8 m special version
  • Cable end:
    Open conductors
  • Standard measuring range:
    2.0 mm
  • Converter mounting:
    DIN rail
  • Converter connections:
    Screw terminals; max. 1.5 mm²
  • Converter frequency range:
    0 to 20 kHz
  • Converter protection:
    IP20
  • Weight:
    0.25 kg
  • Estimated shipping dimensions:
    17x15x4cm
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Long-Body Fit 8 m Open Cable CON041 DIN Rail Product Applications

Features:

  • Long sensor body: Code 009 gives 124 mm total length.
  • Eight-metre lead: The special 3 code selects 8 m cable.
  • DIN-rail conversion: CON041 uses screw-terminal field connections.
The 031 suffix combines an adapter plug with open conductors at the end of the 8 m cable.

The standard PR6423 measuring chain provides a 2 mm range when paired and adjusted correctly.

Installed reach, terminal assignment and converter pairing must be retained during replacement.

Apter Power supports PR6423/009-031 CON041 quotation, documentation and matched-chain review.
  • Extended reach: The 115 mm coded body reaches through deep brackets where a standard short sensor cannot.
  • Installed envelope: The 124 mm total body length must clear nearby covers, guards and maintenance access.
  • Bracket depth: Probe position should be set from the target geometry rather than from body length alone.
  • Unarmored lead: The long-body installation still requires protected cable routing because the lead is not armored.
  • Cabinet reach: The 8 m lead supports remote DIN-rail converter placement without an added field connector.
  • Open termination: Conductors land directly on the CON041 screw terminals and require permanent wire labels.
  • Shield continuity: Cable routing and shield treatment should remain consistent from the sensor to the cabinet entry.
  • Mechanical route: Support the long unarmored run and avoid bends tighter than the documented cable limit.
  • Cabinet environment: The IP20 converter belongs inside a suitable enclosure rather than in an exposed field location.
  • Terminal capacity: Wire-end preparation must suit screw terminals rated for conductors up to 1.5 mm².
  • Rail access: DIN-rail placement should leave room for conductor service and signal checks.
  • Signal response: The 0–20 kHz bandwidth supports the documented vibration and displacement channels.
  • Deep-bracket vibration: Supports radial shaft-motion measurement where the 115 mm body provides the required reach.
  • Remote cabinet layouts: The 8 m open lead suits installations with the converter positioned away from the bearing.
  • Thrust position: Supports axial-position channels when sensor depth and initial gap are verified.
  • Speed or key signal: Supports dynamic reference-pulse measurement through the matched CON041 converter.
Description
For installations requiring extended probe reach, PR6423/009-031 CON041 combines a long-body M10×1 unarmored 8 mm sensor with the CON041 signal converter.

Its Cx 115 mm body, 124 mm total length and 8 m open-ended lead make PR6423/009-031 CON041 dependent on bracket depth, cable routing and correctly assigned screw terminals.

Inside the control cabinet, PR6423/009-031 CON041 places the converter on DIN rail. Target material, initial gap and selected output range define the completed measurement channel.
Alternative Names
PR6423009031 CON041 PR6423 009 031 CON041 PR6423-009-031-CON041 Epro long-body sensor with CON041 PR6423009031CON041 PR6423/009-031 CON041 8 mm Eddy Current Sensor with CON041 Converter PR6423/009-031 CON041 OEM part PR6423/009-031 CON041 technical data
Technical notes
The order matrix decodes PR6423/009-031 CON041 as an M10×1 unarmored 124 mm sensor with adapter, special 8 m cable and open end. CON041 uses DIN-rail mounting and screw terminals, so wire identification and converter pairing are essential.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should the 124 mm sensor length of PR6423/009-031 CON041 be accommodated in the mounting bracket?
This configuration has a 124 mm total sensor length, so a short-body bracket cannot be assumed suitable. Confirm bracket depth and target position before installation.
How should the open-conductor 8 m lead of PR6423/009-031 CON041 be terminated at CON041?
Trace the conductors and shield, then land them on the documented CON041 screw terminals. The open-ended lead should not be connected to a LEMO input.
Can the CON041 converter in PR6423/009-031 CON041 be installed outside a protected control cabinet?
CON041 is an IP20 DIN-rail device, so it requires a suitable cabinet environment. The mounting location should provide the enclosure protection required by the installation.
What should be checked if the output range of PR6423/009-031 CON041 does not match the receiving channel?
Choose the documented negative DC supply and output range for the receiving channel. The selected range determines the required cabinet wiring.
Which checks are required before returning PR6423/009-031 CON041 to service?
The channel is ready only after terminal assignment, target material, initial gap and output response are confirmed. These checks establish that the new geometry is producing the intended signal.
Can the unidentified 8 m cable of PR6423/009-031 CON041 be reused without tracing its conductors?
Trace and identify every conductor and the shield before connecting the open-ended lead to the CON041 screw terminals. Unverified wire assignment can produce an invalid signal.