Features:
- Uses the 16 mm PR 6424 probe family with reverse mounting.
- Provides a ±2 mm static linear range in the calibrated chain.
- Includes an adapter plug, 4 m total cable and LEMO termination.
The current ordering configuration is
PR6424/00R-000, the PR 6424 16 mm Reverse-Mount Eddy-Current Sensor documented for AMS 6500 Machinery Health.
In the intended system role, the sixteen-millimetre probe operates as part of a calibrated non-contact measuring chain for shaft displacement and vibration. Nominal sensitivity is established with the approved converter.
For selection and commissioning, match mounting clearance, target diameter, converter, adapter and cable path before installation. Set the probe gap with the complete chain and prevent the sensing face from touching the shaft.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson PR6424/00R-000:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Measures radial vibration on large rotating shafts without surface contact, for its documented operating duty.
- Tracks axial displacement or thrust position through a matched converter, through the intended receiving-system interface.
- Provides static gap information for machinery condition monitoring, in the configured and commissioned installation.
- The probe and first cable section follow the official PR 6424 temperature limits, for the documented sensor or probe zone.
- The adapter and connector remain within their own rated ambient range, at every exposed connection point.
- Condensation is excluded from the precision connector and converter enclosure, throughout steady-state machinery operation.
- IP66 protection applies to the correctly installed sensor assembly, under the specified installation conditions.
- A minimum sixty-millimetre shaft diameter supports the specified measuring geometry, as part of the installed environmental design.
- Nearby conductive structures must stay outside the required free-space zone, during the final site-suitability review.
- The matched chain supplies a ±2 mm static linear range, within the documented measurement response.
- Nominal sensitivity is four volts per millimetre with the designated converter and target, across the stated usable operating window.
- Non-contact sensing avoids mechanical wear on the monitored shaft, when the specified setup conditions are maintained.