Emerson PR6426-000-030 is a 32 mm large-range eddy current sensor with an 80×40 mm mounting plate, unarmored cable, adapter plug, 8 m total cable and LEMO end.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for PR6426-000-030
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PR6426-000-030

  • Manufacturer:
    Emerson
  • Part Number:
    PR6426-000-030
  • Product Family:
    Epro
  • Product Type:
    32 mm Large-Range Eddy Current Sensor
  • Stock:
    1
  • Mounting plate:
    80 × 40 mm
  • Total cable length:
    8 m
  • Linear measuring range:
    8 mm
  • Nominal center gap:
    Approximately 5.5 mm
  • Sensitivity:
    2 V/mm
  • Reference target:
    42CrMo4 / AISI 4140 steel
  • Minimum shaft diameter:
    200 mm in the exact-family specifications sheet
  • Operating temperature:
    -35 to +175°C; up to +200°C short-term in the exact-family sheet
  • Protection class:
    IP66
  • Standard cable bend radius:
    25 mm
  • Tariff Code:
    9031809090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Plate Mounting Travel Planning Loop Matching Application
  • Confirm the large target and plate-mount envelope before selecting the sensor
  • Protect the unarmored 8 m cable and adapter from mechanical damage
  • Reserve enough gap for the complete expected machine travel

Emerson PR6426-000-030 is a 32 mm large-range eddy current sensor for extended non-contact displacement measurements on large rotating machinery.

The official PR6426/000-030 code specifies the 80×40 mm mounting plate, no cable armor, an adapter plug, 8 m total cable and LEMO end.

Before installation or replacement, verify the large target diameter and free area, mounting-plate alignment, center gap, expected travel, adapter and cable route, converter pairing and monitor range.

Availability, condition, price, and shipping time for PR6426-000-030 are confirmed during quotation.

Emerson PR6426-000-030 Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Mount the documented 80×40 mm plate on a rigid stable surface
  • Align the probe face to the target within the PR6426 angular limit
  • Maintain the required free area around the 32 mm sensing head
  • Center the operating point near the documented nominal gap
  • Include cold-to-hot movement and transient axial travel
  • Keep every normal and fault state inside the verified mechanical clearance
  • Use the converter calibrated for the PR6426 sensitivity and range
  • Keep the adapter and LEMO connections dry and mechanically supported
  • Verify the monitor scale and polarity before enabling trips
  • Large-turbine differential or axial displacement measurement
  • Extended-range shaft position monitoring
  • Slow movement or thermal-growth measurement on large rotating machinery
Description
Emerson PR6426-000-030 is a 32 mm large-range eddy current sensor for extended non-contact displacement measurements on large rotating machinery.

The official PR6426/000-030 code specifies the 80×40 mm mounting plate, no cable armor, an adapter plug, 8 m total cable and LEMO end.

Before installation or replacement, verify the large target diameter and free area, mounting-plate alignment, center gap, expected travel, adapter and cable route, converter pairing and monitor range.
Alternative Names
PR6426-000-030 PR6426/000-030 PR 6426-000-030 PR 6426/000-030 Emerson PR6426-000-030 Emerson PR6426/000-030 Emerson Epro PR6426-000-030 Emerson Epro PR6426/000-030 Epro PR6426-000-030 Epro PR6426/000-030
Technical notes
PR6426-000-030 requires the dedicated plate-mount geometry and a large verified target. Do not apply PR6422, PR6423 or PR6424 gap and bracket assumptions to this large-range sensor.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What machine geometry is required before selecting Emerson PR6426-000-030?
Confirm the large shaft or flat target meets the PR6426 target-size requirement, the 80×40 mm plate can be mounted rigidly and the target travel remains inside the 8 mm linear range.
Can Emerson PR6426-000-030 replace a threaded PR6424 probe?
No direct replacement should be assumed. PR6426 uses a plate mount, larger target, different gap, sensitivity and converter calibration.
Is the adapter plug useful during Emerson PR6426-000-030 replacement?
Yes. It allows the probe section and extension arrangement to be disconnected, but both sides must remain clean, correctly paired and strain relieved.
Why can Emerson PR6426-000-030 become nonlinear near one end of travel?
The target may be outside the calibrated region, too small, tilted, laterally offset or made from a different alloy, or the converter chain may not match the sensor.
What cable risk is higher on the unarmored Emerson PR6426-000-030 version?
The 8 m lead needs mechanical protection from abrasion, crushing and hot surfaces while maintaining the 25 mm minimum bend radius and proper shield routing.
What should be checked if Emerson PR6426-000-030 changes value after the machine warms up?
Compare actual shaft growth and bracket movement with the cold gap, inspect plate stability and target alignment, and verify the monitor polarity and configured range.
How should Emerson PR6426-000-030 be validated after mounting?
Use a controlled mechanical movement or calibrated fixture across the intended span, confirm direction and center gap, then verify monitor scaling and alarm travel before normal operation.

Product Browsing History