Features:
- Pairs a 32 mm eddy-current sensor with the compatible CON021 converter.
- Uses an armored 10 m cable with LEMO termination and no adapter plug.
- Mounts through the documented 80 × 40 mm plate instead of a threaded sleeve.
The current ordering configuration is
PR6426/010-140 CON021, the PR 6426 Eddy-Current Sensor and CON021 Converter Measuring Chain documented for AMS 6500 Machinery Health.
In the intended system role, the /010-140 code selects cable armor, no adapter plug, a ten-metre cable and LEMO end. Together the probe and converter form a calibrated non-contact distance and vibration measurement chain.
For selection and commissioning, confirm the calibrated pair, target geometry, mounting-plate distance, cable routing, supply and output scale before installation. Secure the anti-twist plate after tightening the mounting screws.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson PR6426/010-140 CON021:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Measures large-shaft radial vibration with an extended-range probe geometry, for its documented operating duty.
- Tracks axial position through a calibrated sensor-to-converter chain, through the intended receiving-system interface.
- Provides conditioned static gap and dynamic motion signals to monitoring equipment, in the configured and commissioned installation.
- Machine protection remains bypassed until the calibrated chain has passed a full loop test, before normal operation is permitted.
- The IP20 converter is installed inside a suitable protected cabinet, within a correctly protected installation.
- ESD precautions apply whenever converter electronics or connector contacts are handled, throughout configuration and maintenance work.
- Use is governed by the marking and approvals on the exact sensor and converter supplied, for the exact supplied configuration.
- Installation follows the official clearance, mounting and wiring instructions, under the approved installation conditions.
- Any hazardous-area loop must match the entity parameters of all associated equipment, before any certified service is claimed.
- The converter calibration must correspond to the thirty-two-millimetre probe and target material, as part of the documented hardware combination.
- Total cable length and LEMO termination are part of the measurement scale, before field wiring or device integration is finalized.
- Receiving monitoring electronics must accept the converter's configured output range, so the receiving system interprets the configured signal correctly.