Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power reviews sensor identity, cable condition, documentation, process duty, and quotation details before supply.

396P-08-10-55

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson Rosemount 396P-08-10-55 is a TUpH pH sensor configured with a 10 ft integral lead and no preamplifier.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 396P-08-10-55
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 396P-08-10-55

  • Manufacturer:
    Emerson
  • Part Number:
    396P-08-10-55
  • Product Family:
    Rosemount
  • Product Type:
    TUpH pH Sensor with Integral Cable
  • Stock:
    1
  • Measurement:
    pH
  • Measuring electrode:
    GPLR hemi-bulb glass
  • Sensor family:
    Rosemount 396P TUpH
  • Body material:
    Reinforced polypropylene
  • Reference design:
    Large-area TUpH junction with helical pathway
  • Preamplifier:
    None
  • Integral cable:
    10 ft (3.05 m) coaxial
  • Temperature element:
    Pt100
  • Analyzer group:
    Rosemount 56, 1056, 1057, 1066, and 5081
  • Measurement range:
    0 to 14 pH
  • Process temperature:
    0 to 100 °C
  • Maximum pressure:
    150 psig (10.34 barg) at 100 °C
  • Minimum conductivity:
    100 µS/cm
  • Process threads:
    1 in. MNPT, front and rear
  • Weight:
    0.5 kg
  • Estimated shipping dimensions:
    2.5 x 2.5 x 15.6 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Signal Path TUpH Sensing Process Limits Product Applications

Features:

  • Configured for pH: GPLR hemi-bulb glass covers the 0 to 14 pH range
  • Coating-resistant reference: TUpH technology maintains the measurement path in difficult suspended-solids service
  • Defined loop interface: code 08 supplies a 10 ft cable without an integral preamplifier
396P-08-10-55 combines a rugged polypropylene body with the large-area TUpH junction used for dirty and abrasive processes.

The 10 ft integral cable separates this configuration from shorter and longer 396P cable options, while code 55 fixes the supported analyzer group.

Front and rear 1 in. MNPT threads allow insertion, submersion, or flow-through placement without changing the exact sensor configuration.

Apter Power can review 396P-08-10-55 cable condition, analyzer target, process connection, measurement duty, and quotation scope before supply.
Emerson 396P-08-10-55 TUpH pH Sensor with Integral Cable Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • No preamplifier: the code-08 sensor sends the raw electrode signal through its integral lead.
  • Cable length: the factory configuration provides 10 ft (3.05 m) of coaxial cable.
  • Analyzer boundary: code 55 lists Rosemount 56, 1056, 1057, 1066, and 5081.
  • Temperature input: an integrated Pt100 supports temperature compensation in the measurement loop.
  • Glass selection: GPLR hemi-bulb glass is the code-10 pH electrode.
  • Reference junction: a large-area junction resists coating in high-solids service.
  • Reference pathway: the helical design extends the diffusion path against poisoning ions.
  • Mechanical body: reinforced polypropylene provides the documented chemical-resistant structure.
  • Temperature: the official range reaches 0 to 100 °C.
  • Pressure: the hemi-bulb configuration is rated to 150 psig at 100 °C.
  • Conductivity: the process liquid must meet the 100 µS/cm minimum.
  • Mounting: insertion, submersion, and flow-through arrangements are supported with the documented fittings.
  • Lime-slurry waste treatment: TUpH construction addresses coating and suspended solids.
  • Paper-machine headbox measurement: the reference design suits fibrous, abrasive process liquid.
  • Pigment and dye processes: the polypropylene body and coated-sensor signal stability support difficult streams.
  • Open-tank submersion: the rear 1 in. MNPT connection accepts the documented immersion arrangement.
Description
396P-08-10-55 is an Emerson Rosemount 396P TUpH sensor configured for pH measurement. Its GPLR hemi-bulb glass, reinforced polypropylene body, Pt100 temperature element, and coating-resistant reference design suit difficult aqueous processes with suspended solids.

A 10 ft integral coaxial cable and the absence of an internal preamplifier define how 396P-08-10-55 reaches the analyzer. Code 55 identifies the official Rosemount 56, 1056, 1057, 1066, and 5081 instrument group, giving maintenance teams a precise loop-matching boundary.

For abrasive, dirty, or coating service, 396P-08-10-55 combines a helical reference pathway with 1 in. MNPT process threads at both ends. Insertion, submersion, and flow-through arrangements can therefore use the same sensing platform while keeping the specified temperature, pressure, and conductivity limits in view.
Alternative Names
396P081055 Rosemount 396P code 08 10 55 TUpH GPLR pH sensor 10 ft cable 396P pH sensor without preamplifier
Technical notes
396P-08-10-55 has no integral preamplifier, so its 10 ft coaxial lead must terminate at one of the code-55 Rosemount analyzers or an officially supported junction arrangement. Do not substitute the wiring expectations of a preamplified or Variopol version; preserve cable integrity, shielding, and the Pt100 conductors during routing.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which analyzers are listed for 396P-08-10-55?
Code 55 lists Rosemount 56, 1056, 1057, 1066, and 5081. Match the analyzer model and its pH input before planning the cable termination.
How does the missing preamplifier affect wiring of 396P-08-10-55?
The electrode signal travels through the integral 10 ft coaxial lead without on-sensor amplification. Route it as a measurement cable, preserve shields and Pt100 conductors, and use the analyzer instructions for the selected input.
Where can 396P-08-10-55 be mounted in a process?
Emerson documents insertion, submersion, and flow-through arrangements. Select the fitting and orientation around the front or rear 1 in. MNPT thread without exceeding the process limits.
What process limits matter most for 396P-08-10-55?
Keep the liquid within 0 to 100 °C, observe the 150 psig limit at 100 °C for the hemi-bulb version, and maintain at least 100 µS/cm conductivity.
Why is 396P-08-10-55 suited to dirty or coating service?
Its large-area TUpH reference junction and helical pathway are designed to resist coating and reference poisoning, while the reinforced polypropylene body supports harsh aqueous service.
What should be recorded before replacing 396P-08-10-55?
Capture the complete sensor code, analyzer model, process connection, cable route, current slope and offset, reference condition, temperature response, and the reason the loop was removed from service.