Features:
- Configured for pH: GPLR hemi-bulb glass covers the 0 to 14 pH range
- Coating-resistant reference: TUpH technology maintains the measurement path in difficult suspended-solids service
- Defined loop interface: code 08 supplies a 10 ft cable without an integral preamplifier
396P-08-10-55 combines a rugged polypropylene body with the large-area TUpH junction used for dirty and abrasive processes.
The 10 ft integral cable separates this configuration from shorter and longer 396P cable options, while code 55 fixes the supported analyzer group.
Front and rear 1 in. MNPT threads allow insertion, submersion, or flow-through placement without changing the exact sensor configuration.
Apter Power can review 396P-08-10-55 cable condition, analyzer target, process connection, measurement duty, and quotation scope before supply.
Emerson 396P-08-10-55 TUpH pH Sensor with Integral Cable Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- No preamplifier: the code-08 sensor sends the raw electrode signal through its integral lead.
- Cable length: the factory configuration provides 10 ft (3.05 m) of coaxial cable.
- Analyzer boundary: code 55 lists Rosemount 56, 1056, 1057, 1066, and 5081.
- Temperature input: an integrated Pt100 supports temperature compensation in the measurement loop.
- Glass selection: GPLR hemi-bulb glass is the code-10 pH electrode.
- Reference junction: a large-area junction resists coating in high-solids service.
- Reference pathway: the helical design extends the diffusion path against poisoning ions.
- Mechanical body: reinforced polypropylene provides the documented chemical-resistant structure.
- Temperature: the official range reaches 0 to 100 °C.
- Pressure: the hemi-bulb configuration is rated to 150 psig at 100 °C.
- Conductivity: the process liquid must meet the 100 µS/cm minimum.
- Mounting: insertion, submersion, and flow-through arrangements are supported with the documented fittings.
- Lime-slurry waste treatment: TUpH construction addresses coating and suspended solids.
- Paper-machine headbox measurement: the reference design suits fibrous, abrasive process liquid.
- Pigment and dye processes: the polypropylene body and coated-sensor signal stability support difficult streams.
- Open-tank submersion: the rear 1 in. MNPT connection accepts the documented immersion arrangement.