Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports KC3010X1-BA1 quotations, documentation, sourcing and system matching.

KC3010X1-BA1

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson KC3010X1-BA1 is a 16-channel DeltaV M-series Analog Input Plus card for two-wire process transmitters. It combines conventional signal acquisition with HART device access for controller and asset-management workflows.
In Stock
Ships by Sunday, November 15
Fast Shipping Available
Get a quick price for KC3010X1-BA1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for KC3010X1-BA1

  • Manufacturer:
    Emerson
  • Part Number:
    KC3010X1-BA1
  • Product Family:
    Emerson
  • Product Type:
    16-channel analog input Plus card
  • Stock:
    1
  • Channel count:
    16
  • Input signal:
    4-20 mA, two-wire
  • Full signal range:
    2-22 mA with overrange checking
  • Transmitter power:
    13.5 V minimum at 20 mA
  • Current limit:
    29 mA maximum
  • Accuracy:
    0.2% of span over the temperature range
  • Repeatability:
    0.05% of span
  • A/D resolution:
    16 bit
  • Anti-alias roll-off:
    -3 dB at 2.7 Hz
  • Anti-alias attenuation:
    -20.5 dB at 20 Hz
  • Calibration:
    None required
  • Simplex LocalBus current:
    85 mA typical; 150 mA maximum at 12 VDC
  • Redundant LocalBus current:
    110 mA typical; 200 mA maximum per card at 12 VDC
  • Field-circuit power:
    500 mA maximum at 24 VDC ±10%
  • System isolation:
    Optical; factory tested at 1000 VDC
  • HART pass-through:
    Supported for AMS Device Manager
  • HART data:
    Variable and status reporting for control functions
  • Typical HART scan:
    600-800 ms per enabled channel
  • Card key:
    A6
  • Compatible terminal styles:
    Series 2 Plus 2-wire, 4-wire, redundant or 48-pin mass termination
  • Tariff Code:
    8537101190
  • Country of origin:
    Malaysia
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Performance Communication Integration

Features:

  • Accepts sixteen 4-20 mA analog inputs.
  • Provides 16-bit conversion with HART communication.
  • Uses the A6 DeltaV card-keying position.
The current ordering configuration is KC3010X1-BA1, which is a DeltaV M-series Analog Input Plus card that receives sixteen two-wire 4-20 mA field channels and supports HART data exchange through the Traditional I/O subsystem.

Within the installed DeltaV M-series Traditional I/O architecture, this configuration acquires multichannel process measurements, checks overrange conditions and exchanges HART data with compatible transmitters.

Use the documented A6 keying and matching AI Plus termination arrangement, and verify loop load and field power before commissioning.
Availability is subject to Apter Power inventory and sourcing confirmation.

Verified resources for Emerson KC3010X1-BA1:

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

General

  • ManufacturerEmerson
  • ModelKC3010X1-BA1
  • ConditionNew / Surplus / Refurbished
  • Product FamilyDeltaV M-series Traditional I/O
  • Field-loop current is converted into controller values while abnormal overrange status remains available for diagnostic use.
  • Channels are handled independently so one measurement can be commissioned without redefining adjacent inputs.
  • Transmitter-power planning must consider the complete loop load and cabinet field-power allocation.
  • Supported device variables and status pass to AMS Device Manager when the channel and transmitter are both HART-enabled.
  • Smart-device polling shares the analog loop while normal process-variable acquisition remains active.
  • Asset-data availability depends on transmitter capability and the corresponding DeltaV channel configuration.
  • The keyed carrier position must remain consistent with the selected AI Plus terminal hardware.
  • Simplex and redundant arrangements require their matching carrier wiring and project database definitions.
  • Complete isolation, power-budget and live-loop checks before returning the input card to service.
Description
KC3010X1-BA1 is a DeltaV M-series Analog Input Plus card for sixteen two-wire process loops, combining standard current acquisition with HART-capable smart-transmitter access.

Within Traditional I/O, the card converts field measurements for controller strategies and makes supported device status available to maintenance and asset-management workflows.

Selection must preserve the A6 keyed position, the approved simplex or redundant terminal arrangement, the loop-load allowance and the available field-power budget.
Alternative Names
KC3010X1-BA1 Emerson KC3010X1-BA1 KC3010X1BA1 KC3010X1-BA1 16-channel analog input Plus card DeltaV M-series Traditional I/O KC3010X1-BA1 Emerson DeltaV M-series Traditional I/O KC3010X1-BA1 Emerson DeltaV M-series Traditional I/O 16-channel analog input Plus card
Technical notes
Before energizing KC3010X1-BA1, verify field wiring, power isolation and the validated DeltaV M-series Traditional I/O configuration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which configuration records should be reconciled before commissioning KC3010X1-BA1?
Reconcile the channel database, AI Plus terminal arrangement, HART enablement, loop load and field-power allocation for KC3010X1-BA1.
Which keying and termination details must match KC3010X1-BA1?
Use the documented A6 key position and a compatible DeltaV AI Plus termination arrangement for the required 4-20 mA HART loops.
How does KC3010X1-BA1 support smart process transmitters?
It acquires sixteen 4-20 mA inputs and exchanges HART information when both the transmitter and channel configuration enable HART.
How can a maintenance team check near-term supply of KC3010X1-BA1?
Request an Apter Power availability check with the required quantity and delivery date; the lifecycle label alone does not confirm stock.
Can a standard analog-input card replace KC3010X1-BA1 without review?
No. Channel count, HART support, A6 keying, terminal hardware, loop load and 24 VDC field power must all match.
Where are KC3010X1-BA1 reference links, and what supports an accurate quote?
The Manuals tab provides the verified KC3010X1-BA1 datasheet plus Apter's DeltaV and News links; include the exact model, quantity, destination and loop configuration in the inquiry.