Features:
- Provides 240 KB of configurable memory for logic and controller data.
- Extends Series 90-30 control across as many as eight baseplates.
- Uses a 25 MHz 80386EX processor in a removable single-slot module.
The controller supports larger programs and distributed rack layouts without integrating the CPU into the baseplate.
Its backplane demand is lower than the dual-port floating-point CPU, which affects power-supply selection during replacement.
RAM and Flash provide complementary working and retained storage for the application.
Apter Power assists with pricing and access to official manufacturer documentation for General Electric IC693CPU360 Series 90-30 25 MHz 240 KB CPU Module.
General Electric IC693CPU360 Series 90-30 25 MHz 240 KB CPU Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
IC693CPU360 Control Capacity
- Memory allocation: The large user area can be divided among logic, registers and application data.
- Processor platform: An 80386EX core supports the higher-capacity Series 90-30 controller design.
- Cycle behavior: Actual execution reflects the complete mix of logic, I/O and communication tasks.
- Migration check: A replacement must accommodate both the compiled program and configured data ranges.
IC693CPU360 Expansion Bus
- Eight-baseplate limit: The architecture supports a wider I/O layout than five-rack CPUs.
- Rack identity: Each expansion chassis must use the address expected by the controller project.
- Cable continuity: A broken or incorrectly routed bus link can remove downstream racks from the scan.
- End termination: The final baseplate must complete the expansion bus correctly.
IC693CPU360 Data Retention
- Working RAM: Online logic and changing reference data occupy the volatile memory area.
- Flash storage: The controller can retain a nonvolatile application copy for recovery.
- Battery support: Backup power protects volatile contents during an outage.
- Archive scope: The saved project should include rack configuration and communication parameters as well as logic.
IC693CPU360 System Interfaces
- Programming path: SNP/SNP-X service access is provided through the Series 90-30 power supply.
- Expansion interface: The rack bus carries controller access to modules beyond the main baseplate.
- Option modules: Dedicated communications cards can add application network protocols.
- Replacement comparison: The single-service-port arrangement differs from the dual-front-port CPU design.