Features:
- Thirty-two independently configurable sink input/output points
- Supports 5 VDC logic and 12/24 VDC field power ranges
- Provides a 16 A maximum total block output capacity
The catalog code IC660BBD025 denotes the thirty-two-point sink version; its electronics and terminal assemblies are also identified separately in GE ordering information.
One block can mix sensing and switching duties while reporting circuit data and faults through a single Genius bus connection.
For correct operation, select the voltage range first, then confirm source commons, conductor loading, block current, filter times, and the configured bus address.
The General Electric IC660BBD025 5/12/24 VDC 32-Circuit Sink I/O Block is available for quotation, official documentation, configuration review, and system-matching support from Apter Power.
General Electric IC660BBD025 5/12/24 VDC 32-Circuit Sink I/O Block Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
General Electric IC660BBD025 5/12/24 VDC 32-Circuit Sink I/O Block Specs
General
- ManufacturerGeneral Electric
- ModelIC660BBD025
- ConditionNew Original ready stock
- Product FamilyGE Genius I/O
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Thirty-two-circuit allocation
- Point roles: Assign every circuit separately as an input or an output.
- Voltage choice: Select the documented 5 VDC or 12/24 VDC supply range.
- Total loading: Keep the combined output demand within the 16 A block limit.
- Logic display: Read each indicator on the logic side of its configured point.
Signal response
- Output capacity: Each circuit is rated for 0.5 A steady-state current.
- Inrush allowance: Apply the manual limits when loads draw a startup surge.
- Input delay: Choose a filter value suited to the sensor and process speed.
- Isolation: Maintain required separation around the 850 V block isolation design.
Field integration
- Power source: Verify supply tolerance and ripple before connecting the block.
- Common wiring: Route DC commons according to the sink-circuit diagrams.
- Network identity: Set a unique device number and the correct Genius baud rate.
- Thermal loading: Account for enclosure temperature and simultaneous output current.