Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power can respond to IC5002TAW1000 quotation requests and assist with access to relevant official General Electric manuals.

IC5002TAW1000

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC5002TAW1000 is a 12.1-inch Machine Edition development and runtime Panel PC with an 8000-I/O View and Logic Developer PC license.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC5002TAW1000
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC5002TAW1000

  • Manufacturer:
    General Electric
  • Part Number:
    IC5002TAW1000
  • Product Family:
    GE Intelligent Platforms
  • Product Type:
    12.1-Inch Machine Edition Development and Runtime Panel PC
  • Stock:
    1
  • Display:
    12.1 in TFT color touchscreen
  • Native resolution:
    800 x 600 SVGA
  • Display colors:
    256K
  • Brightness:
    300 cd/m2
  • Processor:
    750 MHz
  • Memory:
    128 MB
  • Hard drive:
    13 GB
  • Optical drive:
    CD-ROM
  • Operating system:
    Windows 2000
  • Application software:
    CIMPLICITY Machine Edition View and Logic Developer PC development and runtime
  • Machine Edition capacity:
    8000 I/O
  • Ethernet:
    Two 10/100BaseT RJ45 ports
  • Serial interfaces:
    COM1, COM2, COM3; touchscreen on COM4
  • USB:
    Two ports, one front and one side
  • Expansion:
    Two shared ISA/PCI
  • Power input:
    100-240 VAC, 50-60 Hz
  • Power consumption:
    48 W typical, 60 W maximum
  • Operating temperature:
    0 to 40 deg C
  • Storage temperature:
    -20 to 60 deg C
  • Humidity:
    10-85% non-condensing
  • Front protection:
    NEMA 4 and IP65
  • Agency approvals:
    UL 1604 Class I, Division 2; CE
  • Weight:
    15.43 lbs (7 kg)
  • Estimated shipping dimensions:
    330 x 268 x 183 mm
  • Tariff Code:
    8471414000
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals ME Development I/O Licensing Project Transfer Engineering Setup

Features:

  • Machine Edition View and Logic Developer PC development plus runtime capability.
  • Licensed capacity for as many as 8000 device I/O points.
  • Compact 12.1-inch touch platform for project creation and local operation.
Development and runtime functions reside on one station, reducing the need to transfer every project change from a separate engineering computer.

The SVGA touch panel, front control keys, and soft keyboard provide a self-contained interface for supported configuration and operating tasks.

Two independent Ethernet adapters connect engineering and control networks, while the serial and expansion interfaces retain access to legacy equipment.

Pricing requests and official documentation for the General Electric IC5002TAW1000 Machine Edition Development Panel PC can be handled by Apter Power.
General Electric IC5002TAW1000 12.1-Inch Machine Edition Development and Runtime Panel PC Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

IC5002TAW1000 Engineering Capability

  • Unified environment: Machine Edition hosts the supported View and Logic PC tools in one interface.
  • Development use: The station can create and modify supported project configurations.
  • Runtime use: The same license includes execution capability for the completed project.
  • Local interface: Touch controls and the soft keyboard support panel-side engineering tasks.

IC5002TAW1000 Point Accounting

  • Licensed total: The order configuration supports up to 8000 I/O points.
  • Device points: Values collected from PLCs, CNCs, and connected devices count toward the limit.
  • Virtual points: Internal CIMPLICITY-only points are not normally counted as device I/O.
  • Project scope: Point use should be reviewed before restoring or migrating an existing project.

IC5002TAW1000 File Movement

  • Optical media: The CD-ROM reads installation and archive discs.
  • Network copy: Project files can move through either configured Ethernet interface.
  • USB access: Front and side USB ports support approved service media.
  • Archive discipline: A current project backup is retained before recovery or major software work.

IC5002TAW1000 Commissioning Sequence

  • Windows account: Initial setup establishes the required Windows 2000 login.
  • Network identity: TCP/IP, workgroup, and domain information are entered for the target site.
  • Touch calibration: The operator surface is calibrated after its COM4 driver is installed.
  • Application launch: Machine Edition starts only after hardware drivers and system settings are confirmed.
Description
IC5002TAW1000 packages the compact 12.1-inch CIMPLICITY Station with Machine Edition View and Logic Developer PC development and runtime capability. Its license supports projects with as many as 8000 I/O points.

The standard hardware in IC5002TAW1000 uses a 750 MHz processor, 128 MB memory, a 13 GB hard disk, and CD-ROM media under Windows 2000. Development tools and runtime operation share the same panel platform.

Because IC5002TAW1000 includes configuration capability, it can be used to create or modify supported HMI and PC-control projects before running them locally. The common Machine Edition environment unifies the applicable development engines.

The compact enclosure supplies a sealed operator surface while retaining network, serial, USB, and expansion access. This lets IC5002TAW1000 serve as both an engineering point and an installed machine interface.
Alternative Names
IC5002-TAW1000 IC5002-TAW-1000 IC5002 TAW1000 IC 5002 TAW 1000 IC5OO2TAW1000 IC5002TAW1OOO 1C5002TAW1000 GE Fanuc IC5002TAW1000
Technical notes
IC5002TAW1000 uses a 2 MB SDRAM VGA controller for its SVGA panel, a hardware detail separate from the Machine Edition license.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can an IC5002TAW1000 project exceed its licensed point count unexpectedly?
IC5002TAW1000 counts collected PLC and CNC device values toward the 8000-I/O license, while ordinary internal virtual points are treated differently.
Can IC5002TAW1000 develop and run a project on the same station?
IC5002TAW1000 includes both Machine Edition development and runtime capability for supported View and Logic PC projects.
How should an IC5002TAW1000 project be backed up?
IC5002TAW1000 projects should be archived using the installed Machine Edition tools and copied to approved removable or network storage.
Does IC5002TAW1000 require an external keyboard for engineering work?
IC5002TAW1000 offers an on-screen soft keyboard, but its PS/2 connection also supports a physical keyboard for extended configuration work.
What should be checked when IC5002TAW1000 cannot communicate with a GE Fanuc PLC?
For IC5002TAW1000, confirm the required communication driver, Ethernet adapter settings, PLC address, and Machine Edition project path before replacing hardware.
What should be preserved before recovering IC5002TAW1000?
IC5002TAW1000 project archives, license information, network settings, and required drivers should be recorded before applying a recovery image.
How is the IC5002TAW1000 touch cursor aligned?
IC5002TAW1000 uses the ELO calibration sequence after the touchscreen driver is assigned to COM4.