Features:
- Provides 16K of editable program RAM for compatible Series Five CPUs.
- Adds a separate 16K register-expansion resource.
- Battery retention and CPU jumper control support a managed memory configuration.
The program and expanded registers are distinct resources and both matter to the running application.
A host jumper defines access to the register expansion, making CPU settings part of the replacement record.
External backup and checksum verification are essential because battery-backed RAM is not an archival copy.
Apter Power can provide quotation support and official-document access for the General Electric IC655MEM503 16K RAM Memory Module.
GE Fanuc IC655MEM503 16K RAM Memory Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Using the additional Series Five register space
- Separate area: The module includes 16K dedicated register RAM.
- CPU setting: A host jumper controls access to the expanded range.
- Application map: Programs must reference the intended register addresses.
- Replacement check: Restore the original host configuration before testing.
Maintaining the editable 16K application image
- Online changes: RAM permits controlled program modification.
- External copy: Keep a verified backup outside the controller.
- Checksum: Compare the restored image with the approved version.
- Capacity fit: Confirm the program and CPU support the memory option.
Avoiding loss of retained memory
- Host battery: Retention depends on the CPU backup source.
- Maintenance timing: Complete the backup before power-down work.
- Battery alarm: Resolve low-battery conditions before moving the module.
- Recovery plan: Store the program and register documentation together.
Checks after memory and CPU settings are restored
- Jumper state: Confirm expanded-register enablement.
- Program image: Verify checksum and software revision.
- Register behavior: Inspect application-critical values and addressing.
- Controlled run: Test the PLC function before production release.