General Electric DS200TCPDG1B is a Mark V LM power distribution module that routes 125 V DC and selected AC supplies from the core to control, I/O, protection, and terminal-board circuits.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for DS200TCPDG1B
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for DS200TCPDG1B

  • Manufacturer:
    General Electric
  • Part Number:
    DS200TCPDG1B
  • Product Family:
    GE Mark V/VI Driver Board
  • Product Type:
    Power Distribution Module
  • Stock:
    1
  • Control Platform:
    Mark V LM SPEEDTRONIC
  • Installed Core:
    power distribution core
  • Primary Distribution:
    125 V DC
  • AC Power Input:
    External 115/230 V AC
  • Branch Control:
    SW1 through SW8
  • Hardware Configuration:
    BJS ground-reference jumper
  • Tariff Code:
    8537109090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Power Routes Switch/Fuse Map Grounding Applications

Features:

  • Separate switched branches distribute power to individual Mark V LM cores and boards.
  • Dedicated connectors feed TCPS, TCEA, TCTG, DTBA, DTBC, DTBD, and CTBA circuits.
  • The BJS jumper supports the panel's external ground-reference arrangement.
DS200TCPDG1B is the central TCPD module in the <PD> core, not a signal-processing board. It accepts the cabinet supply arrangement and routes 125 V DC and selected AC power to defined Mark V LM destinations.

J1R, J1S, J1T, J1C, and J1D serve the TCPS boards in their assigned cores. J7, J8, J12, JPD, and JZ groups serve protection, contact-input, solenoid, monitoring, and AC-related paths.

SW1 through SW8 provide branch control. No software configuration is assigned to the TCPD module.

Apter Power continues to support General Electric DS200TCPDG1B Power Distribution Module sourcing and documentation after the manufacturer's End-of-Life (EOL).
General Electric DS200TCPDG1B Power Distribution Module Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Core and terminal-board feeds

  • Core feeds: J1R, J1S, J1T, J1C, and J1D distribute 125 V DC to TCPS boards in the R1, R2, R3, R5, and R cores. These feeds let a core-specific loss be traced to one connector path.
  • Protection and solenoid paths: J7W feeds TCTG, while J7X, J7Y, and J7Z feed the three TCEA positions in the protective core. J8A through J8D supply DTBC and DTBD solenoid circuits in the digital cores.
  • Contact-input branch: J12A and J12B supply DTBA wetted-contact inputs. The connector name and core destination should agree with the panel drawing before a branch is energized.

Branch isolation logic

  • Core switches: SW1 through SW5 control the R1, R2, R3, R5, and R core feeds. SW6, SW7, and SW8 control the X, Y, and Z TCEA board positions in the protective core.
  • Branch protection: Each switch acts on a defined distribution branch, while the fuse layout protects individual output groups. If only one destination is lost, compare the affected connector with its switch and fuse instead of disturbing unrelated circuits.
  • Repeated fuse operation: An opened fuse should not be replaced repeatedly until the connected cable and load have been checked for the condition that operated it.

BJS configuration

  • BJS reference: The BJS hardware jumper provides ground-reference isolation for systems that use an external reference. With BJS installed, the TCPD provides the ground reference; systems that already establish the reference externally require the alternate BJS position used for that arrangement.
  • Hardware setting: This is a hardware-only setting. DS200TCPDG1B has no software configuration that can correct an incorrect BJS position.
  • Post-change check: After changing TCPD hardware, compare BJS with the 125 V DC grounding diagram before reconnecting branch loads.

Where the TCPD function is used

  • Distributed loads: The TCPD module supports core power conversion through TCPS boards, direct protective-core feeds, digital-core contact and solenoid power, and CTBA power-output monitoring.
  • AC and ignition paths: JZ2 accepts the DACA conversion path when AC input is used. JZ3 provides an alternate reduced-voltage connection for a designated DTBC contact-output circuit, and JZ5 supplies AC power for ignition-transformer outputs.
  • Installed configuration: These paths are application dependent; the installed connector set and project drawings determine which branches are active in a particular Mark V LM panel.
Description
General Electric DS200TCPDG1B is the TCPD Power Distribution Module installed in the Mark V LM PD core. It distributes 125 V DC to TCPS boards in the control and I/O cores and supplies TCEA and TCTG boards in the P1 core.

On DS200TCPDG1B, J8A through J8D feed solenoid power to DTBC and DTBD terminal boards, while J12A and J12B supply DTBA wetted-contact inputs. JPD supports CTBA power-output monitoring, and the JZ connector group carries AC conversion and auxiliary-source paths.

The SW1 through SW8 arrangement on DS200TCPDG1B divides the main core and board power branches so an assigned load can be isolated at the distribution module. BJS establishes the ground-reference arrangement for systems using an external reference.

With no software configuration, DS200TCPDG1B is defined by its incoming sources, switch positions, fuse protection, connector destinations, and BJS hardware setting.
Alternative Names
DS200-TCPD-G1B DS200 TCPD G1B GE DS200TCPDG1B GE Mark V DS200TCPDG1B DS200TCPD G1B DS2O0TCPDG1B DS200TCPDGIB DS200TCPDG1B-GE
Technical notes
On DS200TCPDG1B, J8A/J8C feed DTBC solenoid power, J8B/J8D feed DTBD solenoid power, and J12A/J12B feed DTBA wetted-contact inputs.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can one Mark V core lose power while the others remain energized?
DS200TCPDG1B separates its destinations into switched and fused branches. Trace the affected core through its assigned switch, fuse, and connector instead of treating the outage as a panel-wide supply failure.
What should be checked when a TCPS board has no 125 V DC input?
Follow the DS200TCPDG1B branch at J1R, J1S, J1T, J1C, or J1D for the affected core, then verify the corresponding switch and fuse before testing the TCPS board.
Why can DTBD solenoid outputs be dead even though relay logic is changing?
DS200TCPDG1B supplies the DTBD solenoid-power path through J8B or J8D. Loss of that branch can remove field power while the relay-command path remains active.
What does a repeated DS200TCPDG1B fuse operation point to?
A fuse that opens again indicates an unresolved load, cable, or connector fault on that specific branch. The downstream circuit should be isolated and checked before another fuse is installed.
How should a ground-reference problem after a TCPD change be approached?
Compare the BJS position with the panel drawing and the site external-reference arrangement. An incorrect BJS setting can conflict with the intended 125 V DC ground reference.
Why can a group of wetted contact inputs disappear together?
J12A and J12B are the DS200TCPDG1B feeds to DTBA contact-input power. A fault on the relevant J12 branch can affect a group of inputs without disturbing unrelated circuits.
What must agree before re-energizing DS200TCPDG1B branches?
The incoming source, fuse rating, switch assignment, connector destination, and panel wiring drawing must describe the same branch. Restore one documented branch at a time and confirm its load voltage.