Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, technical documents, sourcing and UR configuration checks for UR6AV.

UR6AV

/ 4.9
1001 reviews | Need a Specific Revision?
GE Multilin UR 6A digital I/O module providing monitored Form-A outputs, Form-C outputs and contact inputs for a compatible relay chassis.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for UR6AV
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for UR6AV

  • Manufacturer:
    General Electric
  • Part Number:
    UR6AV
  • Product Family:
    GE Multilin
  • Product Type:
    UR Digital I/O Module 6A
  • Stock:
    1
  • Manufacturer:
    General Electric / GE Multilin
  • Product family:
    Universal Relay (UR)
  • Product type:
    Digital I/O module
  • Module code:
    6A
  • Form-A outputs:
    2, voltage with optional current monitoring
  • Form-C outputs:
    2
  • Digital inputs:
    8
  • Full model:
    UR6AV
  • Weight:
    0.92 kg
  • Estimated shipping dimensions:
    16.3x4x18.5cm
  • Tariff Code:
    8537101190
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Output Monitoring Slot & Order Code Service Procedure Applications

Features:

  • The 6AV label identifies a 6A module with monitored Form-A output capability.
  • Two Form-C contacts and eight digital inputs extend the host relay interface.
  • Order code, slot and terminal evidence guide accurate module selection.
The module belongs to the configurable GE Multilin Universal Relay hardware platform.

Its full 6AV suffix should be retained because related 6A modules are not automatically interchangeable.

A settings export and chassis record give Apter Power useful context for quotation and compatibility review.

Apter Power can support sourcing and technical review for the General Electric UR6AV UR Digital I/O Module 6A.
General Electric UR6AV UR Digital I/O Module 6A Manuals,Datasheets,Link

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • The two Form-A outputs support voltage monitoring and optional current monitoring within the relay configuration.
  • Monitoring features should be compared with the installed settings before hardware is exchanged.
  • Two additional Form-C outputs provide contact duties defined by the protection application.
  • The complete 6AV code ties the module to a specific Universal Relay hardware order.
  • Chassis slot position and terminal use help distinguish the intended module from similar 6A variants.
  • Apter Power can compare these identifiers with available technical records before quotation.
  • A saved settings file and photographed terminal layout support a controlled replacement record.
  • Post-installation checks can confirm digital indications and both output contact types against the approved scheme.
  • Maintaining the original module label with the service file assists repeat sourcing decisions.
  • GE Multilin UR protection systems configured for the documented 6AV digital I/O module.
  • Relay panels using monitored Form-A outputs, Form-C contacts and eight digital inputs.
  • Maintenance work supported by complete order codes, settings backups and terminal schedules.
Description
UR6AV provides the GE Multilin UR 6A digital-I/O arrangement: two monitored Form-A outputs, two Form-C outputs and eight digital inputs.

UR6AV retains the full 6AV suffix as part of its ordering identity. Relay order code, slot assignment and terminal use should therefore be compared before a module is exchanged.

UR6AV supports contact input and output expansion within a compatible Universal Relay platform. Apter Power provides quotation, document and configuration-comparison support.
Alternative Names
UR 6AV UR-6AV UR 6A V UR6A V GE Multilin UR6AV
Technical notes
For a more predictable exchange, saving the relay settings and recording the installed slot and field terminals preserves the original configuration. The main risk is treating all 6A modules as identical despite different full codes. Apter Power can compare the 6AV label and relay order information before shipment.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which details help Apter Power confirm UR6AV?
The complete relay order code, installed slot, terminal schedule and module label provide the strongest basis for a configuration comparison.
What contact arrangement is shown for UR6AV?
The 6A label identifies two Form-A outputs, two Form-C outputs and eight digital inputs.
Is UR6AV interchangeable with every UR 6A module?
The full suffix, relay order code and supported slot still need comparison because visually related modules are not automatically equivalent.
What records are useful before changing UR6AV?
A settings export and photographed terminal layout preserve the existing relay configuration for commissioning review.
How does monitored output information affect UR6AV selection?
The label notes voltage and optional current monitoring on the Form-A outputs, so the existing relay configuration should be compared before sourcing.
Can Apter Power source and review UR6AV?
Yes. We can prepare a quotation, collect technical records and review the module code against the supplied UR chassis information.