General Electric IC754CSF06CTD is a 6-inch color QuickPanel Control for embedded machine visualization and local control.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC754CSF06CTD
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC754CSF06CTD

  • Manufacturer:
    General Electric
  • Part Number:
    IC754CSF06CTD
  • Product Family:
    GE QuickPanel
  • Product Type:
    QuickPanel Control
  • Stock:
    1
  • Display:
    5.75-inch color TFT
  • Resolution:
    320 x 240 pixels
  • Processor:
    Intel XScale PXA255, 300 MHz
  • Input Power:
    10.8 to 30 VDC
  • Ethernet:
    10/100Base-T
  • Touch Input:
    12-bit resistive
  • Weight:
    2.56 lbs (1.16 kg)
  • Estimated shipping dimensions:
    12.6 x 15.8 x 7 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Interfaces Conditions Setup Applications

Features:

  • Color touch visualization and supported local control execution share one 6-inch panel platform
  • COM1 offers selectable RS-232/485 while COM2 provides a separate RS-232 service channel
  • CompactFlash, dual USB hosts, Ethernet, and fieldbus expansion support a broader Control configuration
IC754CSF06CTD retains user data and selected system settings through its nonvolatile and battery-backed resources when the documented backup procedure is followed.

The Control configuration supports both operator-interface execution and locally executed control logic, distinguishing it from View-only 6-inch terminals.

CompactFlash and expansion-bus access allow approved storage or interface options to be fitted without changing the front-panel operator layout.

The General Electric IC754CSF06CTD QuickPanel Control is available for quotation assistance and access to applicable official manufacturer documentation through Apter Power.
General Electric IC754CSF06CTD Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

IC754CSF06CTD controller and peripheral connections

  • Dual serial roles: IC754CSF06CTD assigns selectable RS-232/485 to COM1 and RS-232 to COM2, so each cable must return to its saved port.
  • Ethernet path: The 10/100Base-T interface carries the network driver and address configured for the Control project.
  • Removable resources: CompactFlash and two USB 1.1 hosts provide separate paths for approved project, storage, or service devices.
  • Expansion planning: Any installed fieldbus expansion must be identified with the panel because it changes the controller interface available after replacement.

IC754CSF06CTD enclosure and operating conditions

  • Front sealing: The documented gasket and panel opening are required to maintain the NEMA 4/4X/12 front rating of IC754CSF06CTD.
  • Operating limits: Use the color Control terminal only within its 0 to 60 °C and 5 to 95% non-condensing range.
  • Heat clearance: Keep ventilation space around the rear electronics and isolate the panel from concentrated solar or enclosure heat.
  • Moisture transition: Allow a cold IC754CSF06CTD to stabilize before energizing it when a temperature change could create condensation.

IC754CSF06CTD replacement and commissioning checks

  • Panel opening: Confirm the 158 x 126 mm cutout and seat the sealing gasket uniformly before tightening the mounting hardware.
  • DC supply: Verify polarity and a 10.8 to 30 VDC source sized for the documented Control-panel demand.
  • Project pair: Back up both the operator-interface target and the locally executed control project before removing the unit.
  • Rear access: Reserve working space for two serial plugs, Ethernet, USB, CompactFlash, expansion hardware, and their cable bends.

IC754CSF06CTD supported machine roles

  • Integrated control cell: Use IC754CSF06CTD where one panel must execute the supported local logic and present the corresponding machine screens.
  • Skid-mounted automation: The unit can combine operator setpoint entry with the control project for a compact packaged system.
  • Multi-interface retrofit: It suits installed panels that depend on separate COM1 and COM2 links together with Ethernet or expansion hardware.
  • Local service station: USB and CompactFlash access support projects that require removable service resources at the machine panel.
Description
IC754CSF06CTD is a General Electric 6-inch QuickPanel Control that places color operator visualization and local control execution in the same panel-mounted unit.

Its 5.75-inch resistive-touch TFT presents alarms, process values, and commands, while the Control configuration can run the supported logic project instead of serving only as a View terminal.

Two differently assigned serial channels, 10/100 Ethernet, USB hosts, CompactFlash, and the expansion interface allow the panel to coordinate controller traffic, project transfer, and approved peripherals within a compact machine architecture.

A replacement therefore requires both project components, COM1/COM2 modes, network identity, removable-media data, and the documented panel opening to be preserved together.
Revisions

Revision Part #

Also known as

IC754CSF06CTDDC
IC754CSF06CTD-DC, Series DC, Rev DC
Alternative Names
IC754 CSF 06 CTD IC-754-CSF-06-CTD 1C754CSF06CTD IC754CSFO6CTD GE IC754CSF06CTD GE Fanuc IC754CSF06CTD QuickPanel IC754CSF06CTD General Electric IC754CSF06CTD
Technical notes
IC754CSF06CTD uses COM1 as selectable RS-232/485 and COM2 as RS-232, so port mode and cable pinout must match the project.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why must both project components be preserved for IC754CSF06CTD?
IC754CSF06CTD supports the operator-interface application and the local control project, so a backup must retain both before hardware replacement.
Which expansion connections can affect an IC754CSF06CTD changeover?
IC754CSF06CTD can use CompactFlash, USB hosts, and an expansion interface in addition to Ethernet and serial ports; record every fitted option before removal.
How should COM1 and COM2 be mapped on IC754CSF06CTD?
IC754CSF06CTD provides different serial capabilities on COM1 and COM2, so the controller cable and port assignment must match the saved project.
Why should IC754CSF06CTD settings be backed up after adjustment?
Some IC754CSF06CTD operating-system and display settings require the supported backup action to remain available after a power cycle.
What separates an IC754CSF06CTD fault from a controller-network fault?
Check IC754CSF06CTD startup status and local operation first, then compare the serial or Ethernet link state with the configured controller driver.
How is the touch surface handled after IC754CSF06CTD service?
Calibrate IC754CSF06CTD when displayed targets no longer align with touch points, and save the resulting settings through the documented procedure.
Where does IC754CSF06CTD fit in a compact control cell?
IC754CSF06CTD can combine local visualization, operator input, communications, and the supported local control application at the machine panel.

Product Browsing History