    Apter Power can assist with IC600CB527 replacement planning by checking supply, returning a quotation, and sharing available original GE I/O records.

IC600CB527

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC600CB527 is a Series Six I/O Control Module that coordinates the primary I/O chain and the CPU interfaces used by programming and data-processing equipment.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for IC600CB527
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC600CB527

  • Manufacturer:
    General Electric
  • Part Number:
    IC600CB527
  • Product Family:
    GE Series Six Plus
  • Product Type:
    I/O Control Module
  • Stock:
    1
  • Control Role:
    Interface between the Series Six CPU and primary I/O chain
  • Peripheral Coordination:
    Programming and data-processor interface transfers
  • Faceplate Connections:
    Primary I/O chain and peripheral interface connectors
  • Indicators:
    CHAIN OK, PARITY, ENABLED and DPU
  • Fault Response:
    Jumper-selected CPU handling for peripheral and communication windows
  • CPU Position:
    Dedicated I/O-control position near the CPU power supply
  • Primary Chain Reach:
    Receiver and downstream rack path within the documented cable limit
  • Backplane Supply:
    5 VDC
  • Current Draw:
    Approximately 1 A
  • Operating Temperature:
    0 to 60 deg C
  • Storage Temperature:
    0 to 70 deg C
  • Relative Humidity:
    5% to 95%, noncondensing
  • Estimated shipping dimensions:
    31.7x28.0x3.0cm
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Chain Path Jumpers Peripherals Indicators

Features:

  • Links the Series Six CPU with its primary I/O chain.
  • Coordinates supported programmer and data-processor transfers.
  • Separates chain, parity, output-enable, and DPU conditions with four indicators.
IC600CB527 occupies the control point between processor execution and the main Series Six I/O path.

Its indications summarize conditions that can originate locally or in connected receivers, cables, and racks.

Effective service starts with the saved topology and jumper record rather than an immediate board exchange.

For General Electric IC600CB527 I/O Control Module sourcing and original documentation support, contact Apter Power.
General Electric IC600CB527 I/O Control Module Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Trace the main I/O path end to end

  • I/O chain: Identify the first receiver, every downstream rack, the total cable route, and the power source at each station connected through IC600CB527.
  • Parity response: A continuity or parity symptom can be propagated from remote hardware.
  • Indicator meaning: Capture which indicators change before disconnecting any segment.
  • Staged restart: Reconnect and test the chain in controlled stages after service.

Preserve the configured CPU response

  • Jumper settings: IC600CB527 jumper choices determine how the CPU handles selected peripheral or communication-window failures.
  • Setting capture: Photograph and transcribe those positions before removal.
  • Configuration record: Do not copy settings from a spare that came from a different machine.
  • Fault response: Verify the resulting alarm and STOP behavior during a safe commissioning test.

Check the programmer and data path separately

  • Program record: The peripheral connector supports the supported programming or data-processing equipment.
  • I/O continuity: A failure here can exist while the primary I/O chain remains healthy.
  • Cable path: Inspect cable orientation, connector hardware, and the configured DPU presence before replacing IC600CB527.
  • External connection: Prove the peripheral transfer with a known operation after the CPU is stable.

Use all four lamps before isolating the fault

  • Parity response: CHAIN OK, PARITY, ENABLED, and DPU describe different parts of the IC600CB527 environment.
  • Fault evidence: Record the pattern with the system in its failed state, then compare it with downstream power and receiver indications.
  • Operational effect: Avoid clearing evidence by cycling power too early.
  • Output control: Enable outputs only after continuity and the actual point map have been confirmed.
Description
General Electric IC600CB527 is a Series Six I/O Control Module for the CPU rack. Its operating role is to connect the processor with the primary I/O chain while coordinating data exchange with supported programming and data-processing peripherals.

The faceplate path includes the I/O-chain connection and the peripheral interface. CHAIN OK, PARITY, ENABLED, and DPU indications separate continuity, data-integrity, output-state, and peripheral conditions during service.

A reported chain fault may originate beyond IC600CB527 in the receiver, cable, rack supply, or downstream station. The module should therefore be tested with the complete primary-chain topology and normal indicator pattern available.

Before replacement, capture the jumper choices that determine CPU response to communication or peripheral-window faults. Install the board in the documented I/O-control position, restore cabling with power removed, and recommission with outputs disabled.
Alternative Names
IC600-CB527 IC600CB-527 IC 600 CB 527 GE IC600CB527 GE Fanuc IC600CB527 General Electric IC600CB527 Series Six IC600CB527 IC600CB527 I/O Control
Technical notes
Record IC600CB527 jumper positions, cable destinations, primary-chain topology, CPU alarms, DPU state, parity indication, and output-enable sequence before removal.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why should the primary I/O chain be mapped before IC600CB527 is replaced?
IC600CB527 reports conditions from the connected receivers and racks. A topology map lets technicians distinguish the local control board from a downstream cable or power fault.
What do the IC600CB527 indicators help separate?
IC600CB527 uses CHAIN OK, PARITY, ENABLED, and DPU indications to separate chain continuity, data integrity, output state, and peripheral-interface conditions.
What settings should be recorded on IC600CB527?
Capture the IC600CB527 fault-response jumpers, full suffix, rack position, both cable destinations, normal indicator pattern, and CPU behavior for window failures.
Can a dark CHAIN OK lamp prove IC600CB527 has failed?
No. On IC600CB527, a receiver, I/O cable, downstream rack power supply, or output-data parity problem can also remove the chain indication.
Why should IC600CB527 outputs remain disabled during testing?
Keeping IC600CB527 outputs disabled allows the primary chain, parity, point map, peripheral path, and safe field state to be verified without unexpected actuation.
How should a DPU-related IC600CB527 fault be investigated?
Check the IC600CB527 peripheral cable, DPU presence setting, connector condition, power, and configured CPU response before substituting the control module.
What should be saved before disconnecting IC600CB527?
Retain the rack drawing, I/O-chain layout, cable labels, jumper positions, CPU alarms, indicator state, address map, and output-enable procedure associated with IC600CB527.