CC-GAOX11

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell CC-GAOX11 is a redundant 12-inch GI/IS Analog Output IOTA for up to sixteen 4–20 mA channels.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for CC-GAOX11
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for CC-GAOX11

  • Manufacturer:
    Honeywell
  • Part Number:
    CC-GAOX11
  • Product Family:
    Honeywell Experion PKS ( C200, C300 )
  • Product Type:
    GI/IS Analog Output IOTA
  • Stock:
    1
  • Redundancy:
    Supported
  • High-Density Layout:
    No
  • Output Channels:
    Up to 16
  • Output Signal:
    4–20 mA
  • MTL4546C Support:
    16 single-channel HART isolators
  • MTL4549C Support:
    8 dual-channel HART isolators
  • Open-Wire Detection:
    Supported by listed output isolators
  • Unused Connectors:
    MTL4599 dummy isolator
  • Safety Interface:
    Integrated intrinsically safe interface
  • Isolation Function:
    Galvanic isolation through supported MTL isolators
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Redundancy Review Output Isolators Wiring Boundary

Features:

  • Redundant output assembly: The 12-inch IOTA supports a redundant Analog Output arrangement.
  • Sixteen 4–20 mA channels: The official guide documents up to sixteen outputs.
  • Flexible isolator population: Single-channel MTL4546C and dual-channel MTL4549C options are listed.

CC-GAOX11 routes Series C analog commands through plug-in galvanic isolators to hazardous-area 4–20 mA field devices.

Single-loop integrity favors MTL4546C, while MTL4549C provides two channels per isolator; the fitted population determines cabinet layout.

Replacement preparation should preserve the redundant IOM configuration, HART device records, channel assignment, and open-wire diagnostics.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

Honeywell CC-GAOX11 GI/IS Analog Output IOTA Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Honeywell CC-GAOX11 GI/IS Analog Output IOTA Specs

General

  • ManufacturerHoneywell
  • ModelCC-GAOX11
  • ConditionNew Original ready stock
  • Product FamilyExperion Series C GI/IS IOTAs

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Redundant output architecture

  • IOTA format: Use the official 12-inch redundant assembly.
  • IOM arrangement: Confirm both Analog Output IOM positions.
  • Channel scope: Keep the configured output count within sixteen.
  • Project record: Back up channel and redundancy configuration before replacement.

Supported output devices

  • MTL4546C: Use up to sixteen single-channel HART isolators.
  • MTL4549C: Use up to eight dual-channel HART isolators.
  • Open-wire function: Both listed isolators provide the documented open-wire detection.
  • MTL4599: Terminate unused connectors with the dummy isolator when required.

Hazardous-area interface

  • Signal type: Use the documented 4–20 mA output channels.
  • Intrinsic safety: The supported isolators provide the IS interface.
  • Galvanic isolation: The plug-in isolators separate hazardous and safe-area circuits.
  • Commissioning: Verify loop polarity, field-device records, and channel diagnostics.
Description
The Honeywell CC-GAOX11 is a redundant 12-inch GI/IS Analog Output IOTA for Experion Series C I/O.

Official documentation for CC-GAOX11 specifies up to sixteen 4–20 mA outputs and accepts MTL4546C single-channel or MTL4549C dual-channel HART isolators with open-wire detection.

Before ordering CC-GAOX11, verify the redundant IOM pair, output channel map, isolator type and quantity, HART use, and full model label.
Alternative Names
Honeywell CC-GAOX11 CC-GAOX11 CC GAOX11 CCGAOX11 Honeywell Series C CC-GAOX11 Experion PKS CC-GAOX11 IOTA CC-GAOX11 analog output IOTA GI/IS Analog Output IOTA CC-GAOX11
Technical notes
Honeywell CC-GAOX11 provides up to sixteen 4–20 mA outputs on a redundant 12-inch GI/IS IOTA. Confirm the selected MTL4546C or MTL4549C isolators.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is Honeywell CC-GAOX11 used for?
It provides up to sixteen galvanically isolated 4–20 mA outputs in a redundant Experion Series C GI/IS arrangement.
Which product family includes CC-GAOX11?
CC-GAOX11 belongs to Honeywell Experion Series C GI/IS IOTAs. Verify the associated Analog Output IOM pair.
How do I verify the correct CC-GAOX11?
Match the model, 12-inch redundant format, output count, isolator population, and channel wiring to the installed assembly.
Which isolators are listed for CC-GAOX11?
Honeywell lists MTL4546C, MTL4549C, and MTL4599. Confirm whether single-channel or dual-channel output isolation is required.
Is CC-GAOX11 active or discontinued?
The reviewed Honeywell guide does not state that CC-GAOX11 is discontinued. Current supply requires sourcing confirmation.
Is CC-GAOX21 a direct replacement for CC-GAOX11?
No official direct-replacement statement is provided. The models differ in redundancy, size, density, and permitted isolator population.
Where can I get the CC-GAOX11 datasheet and price?
Open the verified PDF in Manuals, then send Apter Power the quantity, destination, condition, isolator selection, and required date.