The Honeywell TC-PCIC02 is a PCI-bus based ControlNet communication interface module that provides a high-speed, deterministic link between host workstations and Honeywell distributed control systems.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for TC-PCIC02
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for TC-PCIC02

  • Manufacturer:
    Honeywell
  • Part Number:
    TC-PCIC02
  • Product Family:
    Honeywell Experion PKS ( C200, C300 )
  • Product Type:
    ControlNet Interface Module
  • Stock:
    1
  • Data Transfer Rate:
    5 Mbps
  • Compatibility:
    Honeywell Experion PKS, TDC 3000, C200/C200E Controllers
  • Power Supply:
    5 VDC at 700 mA (via PCI bus)
  • Operating Temperature:
    0°C to 60°C (32°F to 140°F)
  • Storage Temperature:
    -40°C to 85°C (-40°F to 185°F)
  • Relative Humidity:
    5% to 95% (Non-condensing)
  • Certifications:
    CE, UL (Typical for industrial control equipment)
  • Weight:
    0.12 kg
  • Estimated shipping dimensions:
    2.1x18.3x12.5cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Applications Safety & Compliance Environmental Ratings

Features:

  • Deterministic ControlNet Communication
  • Seamless Integration with Experion PKS
  • Robust Redundancy Support
The Honeywell TC-PCIC02 utilizes the ControlNet protocol to provide time-critical data transfer. Unlike standard Ethernet, ControlNet ensures predictable update times for I/O and peer-to-peer messaging, making it ideal for real-time process control and logic synchronization.

Designed specifically for Honeywell architecture, the Honeywell TC-PCIC02 allows the Experion Control Builder software to directly access C200/C300 controllers. This direct PCI connection bypasses standard network layers, offering a dedicated path for controller configuration, online edits, and firmware upgrades.

The Honeywell TC-PCIC02 fully supports ControlNet media redundancy. It can manage active/standby communication channels, ensuring zero-downtime in the event of a cable break or adapter failure, thereby maintaining system availability for critical process operations.

The TC-PCIC02 Honeywell ControlNet Interface Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell TC-PCIC02 ControlNet Interface Module, PCI bus Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Honeywell TC-PCIC02 ControlNet Interface Module, PCI bus

General

  • Manufacturer Honeywell
  • Model TC-PCIC02
  • Condition New Original ready stock
  • Product Family TC-PPD011,TC-PRR021,TC-FTEB01
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Legacy System Maintenance: Ideal for brownfield expansions where the Honeywell TC-PCIC02 connects engineering workstations to existing C200/C200E controllers during the "Legacy" and "Phase-out" support phases.
  • High- Availability Process Control: Used in oil refineries and chemical plants where the Honeywell TC-PCIC02 supports redundant ControlNet media to ensure uninterrupted data flow between operators and field devices.
  • Dedicated Engineering Access: Allows engineers to use the Honeywell TC-PCIC02 as a dedicated "heartbeat" monitoring link for troubleshooting network issues without disturbing production traffic on the main FTE (Fault Tolerant Ethernet) network.
  • Migration Projects: Employed as an intermediate solution during the stepwise upgrade from TDC 3000 to Experion PKS, where the Honeywell TC-PCIC02 allows coexistence of legacy networks with new servers.
  • Industrial Control Equipment: The Honeywell TC-PCIC02 meets standard UL and CE markings for industrial electrical equipment, ensuring safe installation in control cabinets.
  • Hazardous Location Suitability: While the card itself is rated for general purpose, when installed in a properly rated workstation, the Honeywell TC-PCIC02 can be utilized in ATEX/IECEx Zone 2 environments (depending on the workstation certification).
  • Network Security (Defense in Depth): The Honeywell TC-PCIC02 operates on the isolated ControlNet physical layer, which inherently provides "air gap" style security for control traffic, as it does not natively route TCP/IP packets.
  • Electromagnetic Compatibility (EMC): Designed to comply with IEC 61000-6-2 (Immunity for industrial environments) and IEC 61000-6-4 (Emission standard), ensuring the Honeywell TC-PCIC02 does not interfere with sensitive analog instruments.
  • Thermal Limits: The Honeywell TC-PCIC02 supports an operating range of 0°C to 60°C, suitable for temperature-controlled control rooms but requiring climate control in hotter climates.
  • Humidity Resistance: Rated for 5-95% non-condensing humidity, the Honeywell TC-PCIC02 withstands humid environments typical of pulp and paper or wastewater facilities without corrosion damage.
  • Physical Shock & Vibration: Designed to survive the low-level vibration of standard industrial enclosures (e.g., fan assemblies); however, the Honeywell TC-PCIC02 relies on the PCI slot for mechanical support and should be secured in mobile applications.
  • Storage Durability: With a storage range of -40°C to 85°C, the Honeywell TC-PCIC02 can be safely kept in spare parts warehouses without climate control, ensuring long-term shelf life.
Description
The Honeywell TC-PCIC02 serves as a dedicated communication processor designed to interface Engineering Workstations (EWS) and Operator Stations with the ControlNet network backbone. As a critical component for systems like Experion PKS and legacy TDC 3000, this module enables direct connectivity between PC-based configuration tools and the C200/C200E controller platform, facilitating control logic downloads, real-time data acquisition, and system diagnostics .

Engineered for deterministic performance, the Honeywell TC-PCIC02 supports the 5 Mbps ControlNet protocol, ensuring scheduled and unscheduled data transfers without network collisions . It is specifically designed to occupy a standard PCI slot inside a workstation, providing a physical layer connection via coaxial media (or fiber through external adapters). This hardware-level access is essential for tasks requiring low-level controller interaction, such as redundancy management and firmware updates.

As industrial networks evolve, the Honeywell TC-PCIC02 remains a vital tool for brownfield expansions and legacy system maintenance. While newer Experion releases support Ethernet-based virtual engineering environments, the TC-PCIC02 is indispensable for sites operating Experion R300 to R510 on physical workstations. It guarantees stable interoperability with Series A I/O and classic C200 controllers, protecting long-term capital investments.
Alternative Names
TCPCIC02 TC-PC1C02 TC-PCICO2 TC-PPD011 TC-PRR021 TC-FTEB01 TC-IXR061
Technical notes
The Honeywell TC-PCIC02 is a PCI-bus based ControlNet interface designed specifically to provide deterministic communication between an engineering workstation and C200/C200E controllers in Experion PKS environments. Unlike standard Ethernet cards, the Honeywell TC-PCIC02 supports redundant media operation and operates at a fixed 5 Mbps rate, requiring correct termination and node addressing on the trunk line to prevent network scheduling failures.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the primary function of the Honeywell TC-PCIC02?
The Honeywell TC-PCIC02 is a PCI bus interface card designed to connect a PC workstation to a ControlNet network. Its primary function is to allow engineering software (like Control Builder) to communicate directly with Honeywell C200/C200E controllers for configuration, logic download, and real-time monitoring.
Which software versions are compatible with the Honeywell TC-PCIC02?
The Honeywell TC-PCIC02 is compatible with Experion PKS releases from R300 through R510. It requires specific Honeywell drivers installed on the host operating system (typically Windows-based Engineering Workstations). It does not support virtualized environments or modern blade servers without specific hardware passthrough.
What diagnostic capabilities does the Honeywell TC-PCIC02 provide?
The Honeywell TC-PCIC02 provides low-level access to controller health diagnostics, network status metrics, and I/O dropout detection. It allows engineers to view ControlNet specific statistics (e.g., scheduled nodes, network load, and redundancy status) directly from the engineering client.
What are the physical installation requirements for the Honeywell TC-PCIC02?
The Honeywell TC-PCIC02 must be installed in a standard 32-bit PCI slot inside a physical workstation. It is not hot-swappable; installation requires the workstation to be powered off. The module connects to the ControlNet trunk via a BNC connector (coaxial).
Can the Honeywell TC-PCIC02 communicate with third-party PLCs?
The Honeywell TC-PCIC02 strictly adheres to the ControlNet protocol (CIP). While it can physically connect to third-party ControlNet devices (like Rockwell Automation 1756-CNx modules), its driver stack is optimized for Honeywell object models. Integration requires standard ControlNet routing configuration but is primarily designed for Honeywell Experion environments.