Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    For FS-SDIL-1608 requirements, Apter Power can provide current pricing and sourcing assistance for the required quantity and delivery schedule.

FS-SDIL-1608

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell FS-SDIL-1608 is a 16-channel loop-monitored safe digital input module with earth-fault supervision for Honeywell Safety Manager.
In Stock
Ships by Saturday, October 31
Fast Shipping Available
Get a quick price for FS-SDIL-1608
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FS-SDIL-1608

  • Manufacturer:
    Honeywell
  • Part Number:
    FS-SDIL-1608
  • Product Family:
    Honeywell FSC Series
  • Product Type:
    16-Channel Loop-Monitored Safe Digital Input Module
  • Stock:
    1
  • Safe input channels:
    16
  • Supported field signals:
    Monitored contacts or DIN NAMUR proximity sensors
  • Switching threshold:
    1.4-1.9 mA with BN-1608
  • Typical low-pass filter:
    100 Hz
  • Loop supply:
    7.9-8.7 V with BN-1608
  • Field-wire resistance:
    Maximum 50 ohm
  • Power demand:
    5 V: 160 mA; 24 V: 110 mA
  • Construction:
    Non-conformal-coated FS version
  • Tariff Code:
    85389000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Data Diagnostics Compatibility Installation Check

Features:

  • Sixteen loop-monitored safe digital inputs
  • DIN NAMUR and monitored-contact compatibility
  • Integrated earth-fault and line-fault supervision
FS-SDIL-1608 converts monitored field-loop conditions into supervised digital states.

The converter, sensor current and cable resistance determine actual thresholds and fault detection.

Earth-fault performance must be proven with the installed grounding and shielding arrangement.

The Honeywell FS-SDIL-1608 16-Channel Loop-Monitored Safe Digital Input Module is available for quotation and technical support from Apter Power.
Verified resources for FS-SDIL-1608:

Input Data:

  • Safe input channels: 16
  • Supported field signals: Monitored contacts or DIN NAMUR proximity sensors
  • Switching threshold: 1.4-1.9 mA with BN-1608
Use the documented FS-SDIL-1608 limits when calculating the complete field circuit.

Diagnostics:

  • Open- and short-circuit supervision
  • Earth-fault test path
  • Channel crosstalk and supply self-tests
Resolve all FS-SDIL-1608 channel, wiring and system diagnostics before release to operation.

Compatibility:

  • BN-1608 or BSN-1608 conversion
  • DIN NAMUR proximity and monitored contacts
  • Key coding A5/C29
Match FS-SDIL-1608 to the approved Safety Manager module, termination and field-device arrangement.

Installation Check:

  • Confirm loop polarity and resistance
  • Verify shield and earth arrangement
  • Prove normal and fault states
Complete and record the end-to-end functional test after installing FS-SDIL-1608.
Description
Honeywell FS-SDIL-1608 16-Channel Loop-Monitored Safe Digital Input Module provides sixteen loop-monitored safe digital inputs plus earth-fault supervision for Honeywell Safety Manager.

BN-1608 or BSN-1608 conversion lets the module evaluate contact or DIN NAMUR current thresholds, open and short circuits and earth leakage. Internal tests also supervise crosstalk and power.

Match the converter board, field sensor, cable resistance and shield or earth arrangement to the engineered loop. Prove normal, alarm, open, short and earth-fault states before service.
Alternative Names
FS-SDIL-1608 FS SDIL 1608 FSSDIL1608 Honeywell FS-SDIL-1608 Honeywell FS SDIL 1608 Honeywell FSSDIL1608 FS-SDIL-1608 16-Channel Loop-Monitored Safe Digital Input Module Honeywell Safety Manager FS-SDIL-1608
Technical notes
FS-SDIL-1608 supervises sixteen contact or NAMUR input loops and includes earth-fault monitoring. Verify the exact field interface and approved system configuration before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How are open and short circuits detected?
The approved converter establishes monitored current windows that distinguish process states from line faults.
Can DIN NAMUR sensors connect directly?
They can be used only with the documented converter, wiring and sensor-current thresholds.
What field-wire resistance is permitted?
Honeywell documents a maximum of 50 ohm for the BN-1608 arrangement.
Which hardware must be matched with FS-SDIL-1608?
Verify BN-1608 or BSN-1608 conversion, DIN NAMUR proximity and monitored contacts and the approved Safety Manager hardware list before installation.
Which diagnostics are important for FS-SDIL-1608?
Check open- and short-circuit supervision, earth-fault test path, channel crosstalk and supply self-tests and clear every unexplained channel or system alarm.
Can another construction variant replace FS-SDIL-1608?
Only after environmental construction, certifications, hardware revision and project approval have been confirmed.
What commissioning checks are required for FS-SDIL-1608?
Perform these product-specific checks: confirm loop polarity and resistance, verify shield and earth arrangement, prove normal and fault states; document the final results.
What information is needed to quote FS-SDIL-1608?
Provide the exact module model, hardware revision, connected field circuit, required construction, quantity and destination.

Product Browsing History