    SP-EBLDR1 remains documented as the ControlEdge Builder client license; release compatibility must be confirmed for the target controller and engineering workstation.

SP-EBLDR1

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell SP-EBLDR1 is a controledge builder client license for the ControlEdge engineering environment.
In Stock
Ships by Saturday, October 31
Fast Shipping Available
Get a quick price for SP-EBLDR1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for SP-EBLDR1

  • Manufacturer:
    Honeywell
  • Part Number:
    SP-EBLDR1
  • Product Family:
    Honeywell FSC Series
  • Product Type:
    ControlEdge Builder Client License
  • Stock:
    1
  • License basis:
    Per client computer
  • Installation quantity:
    One license per physical or virtual computer
  • Operating mode:
    Online and offline engineering
  • Engineering function:
    Design, configure, program and maintain ControlEdge RTU
  • Programming standard:
    IEC 61131-3
  • Supported languages:
    LD, FBD, ST, IL and SFC
  • Controller connection:
    Ethernet
  • Project operations:
    Program replication, download, diagnostics and data-log upload
  • Tariff Code:
    85234920
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals License Data Compatibility Deployment Installation Check
Product overview:
  • One license per physical or virtual engineering computer
  • Online and offline ControlEdge RTU engineering
  • IEC 61131-3 configuration, programming and maintenance
Honeywell SP-EBLDR1 licenses one ControlEdge Builder client installation on a physical or virtual engineering computer. The software provides the configuration environment used to design, configure, program and maintain ControlEdge RTU applications.

SP-EBLDR1 supports both online and offline work. Documented engineering functions include IEC 61131-3 programming, Ethernet communication with the RTU, program replication, remote download, firmware operations, diagnostics and data-log retrieval.

Plan one SP-EBLDR1 license for every computer that will host ControlEdge Builder. Before deployment, match the Builder release to the controller firmware, archive the current project and verify that the workstation operating environment supports the required engineering release.
Verified resources for SP-EBLDR1:
License Data:
  • License scope: one Builder client
  • Installation basis: per computer
  • Use mode: online and offline
Use the documented SP-EBLDR1 entitlement or release data when planning the engineering environment.
Compatibility:
  • Match Builder and controller firmware releases
  • Confirm workstation operating-system support
  • Preserve a validated project archive
Compatibility for SP-EBLDR1 depends on the exact software release, controller firmware and validated project revision.
Deployment:
  • Allocate one license to each engineering station
  • Install the approved Builder release
  • Control project and firmware access
Deploy SP-EBLDR1 under controlled engineering access and retain the installation and entitlement records.
Installation Check:
  • Verify the license entitlement
  • Back up the controller project
  • Test communications before making changes
Complete release, project and communication checks before SP-EBLDR1 is used on a production system.
Description
SP-EBLDR1 ControlEdge Builder Client License licenses one ControlEdge Builder client installation on a physical or virtual engineering computer. The software provides the configuration environment used to design, configure, program and maintain ControlEdge RTU applications.

SP-EBLDR1 supports both online and offline work. Documented engineering functions include IEC 61131-3 programming, Ethernet communication with the RTU, program replication, remote download, firmware operations, diagnostics and data-log retrieval.

Plan one SP-EBLDR1 license for every computer that will host ControlEdge Builder. Before deployment, match the Builder release to the controller firmware, archive the current project and verify that the workstation operating environment supports the required engineering release.
Alternative Names
SP-EBLDR1 SP EBLDR1 SPEBLDR1 Honeywell SP-EBLDR1 Honeywell SP EBLDR1 Honeywell SPEBLDR1 ControlEdge SP-EBLDR1 SP-EBLDR1 ControlEdge Builder Client License
Technical notes
SP-EBLDR1 is the per-computer ControlEdge Builder client license for online and offline RTU engineering. Match the Builder release, controller firmware and project archive before connecting to a production controller.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How many SP-EBLDR1 licenses are required?
Use one license for each physical or virtual computer on which ControlEdge Builder is installed.
Can SP-EBLDR1 be used offline?
Yes. The documented Builder client license supports online and offline engineering.
Which programming languages are supported?
ControlEdge Builder supports Ladder Diagram, Function Block Diagram, Structured Text, Instruction List and Sequential Function Chart.
How does the engineering station communicate with the RTU?
The documented communication medium is Ethernet; network access and controller security must follow the site design.
Can one license cover several engineering computers?
No. Each physical or virtual computer hosting Builder requires its own client license.
What should be checked before connecting to a controller?
Match the Builder and firmware releases, back up the project and confirm authorized network access.
Does the license include controller runtime execution?
No. SP-EBLDR1 is the Builder client entitlement; controller execution licenses are separate where required.
What information is needed to quote SP-EBLDR1?
Provide the computer count, required Builder release, controller models, firmware versions, quantity and destination.