Honeywell FC-SDO-0824 is an 8-channel 24 V DC safe source-output module rated to 550 mA per channel for Honeywell Safety Manager.
In Stock
Ships by Saturday, October 31
Fast Shipping Available
Get a quick price for FC-SDO-0824
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FC-SDO-0824

  • Manufacturer:
    Honeywell
  • Part Number:
    FC-SDO-0824
  • Product Family:
    Honeywell FSC Series
  • Product Type:
    8-Channel 24 V DC Safe Digital Output Module
  • Stock:
    1
  • Safe output channels:
    8
  • Nominal field voltage:
    24 V DC
  • Maximum channel current:
    550 mA
  • Lamp load:
    Maximum 120 mA / 2.9 W
  • Maximum load capacitance:
    1 microfarad
  • Voltage drop:
    Less than 2 V at 500 mA
  • Watchdog current:
    8 mA
  • Construction:
    Conformal-coated FC version
  • Tariff Code:
    85389000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Output Data Diagnostics Compatibility Installation Check

Features:

  • Eight 24 V DC safe source outputs
  • Up to 550 mA per channel
  • Short-circuit protection and output diagnostics
FC-SDO-0824 switches eight independent DC field loads from the safety application.

Field-supply capacity and load characteristics must stay inside current, capacitance and inrush limits.

Commissioning should prove command, terminal voltage, actuator response and safe de-energization together.

The Honeywell FC-SDO-0824 8-Channel 24 V DC Safe Digital Output Module is available for quotation and technical support from Apter Power.
Verified resources for FC-SDO-0824:

Output Data:

  • Safe output channels: 8
  • Nominal field voltage: 24 V DC
  • Maximum channel current: 550 mA
Use the documented FC-SDO-0824 limits when calculating the complete field circuit.

Diagnostics:

  • Short-circuit-protected channels
  • 8 mA watchdog current
  • Command and field-feedback supervision
Resolve all FC-SDO-0824 channel, wiring and system diagnostics before release to operation.

Compatibility:

  • Resistive and approved DC loads
  • Maximum 1 microfarad capacitance
  • Key coding A9/C9
Match FC-SDO-0824 to the approved Safety Manager module, termination and field-device arrangement.

Installation Check:

  • Verify field-supply polarity
  • Check fuse and conductor ratings
  • Prove every output and trip state
Complete and record the end-to-end functional test after installing FC-SDO-0824.
Description
Honeywell FC-SDO-0824 8-Channel 24 V DC Safe Digital Output Module provides eight short-circuit-protected 24 V DC safe source outputs for Honeywell Safety Manager.

Each channel supports up to 550 mA, with documented limits for lamp inrush, capacitance, voltage drop and off-state current. Diagnostics supervise the output stage, but load behavior and field-power protection remain part of the circuit design.

Size power distribution, fuses, conductors, suppression and return paths for every actuator. Prove energized, de-energized, fault and safety-trip behavior under the actual load.
Alternative Names
FC-SDO-0824 FC SDO 0824 FCSDO0824 Honeywell FC-SDO-0824 Honeywell FC SDO 0824 Honeywell FCSDO0824 FC-SDO-0824 8-Channel 24 V DC Safe Digital Output Module Honeywell Safety Manager FC-SDO-0824
Technical notes
FC-SDO-0824 provides eight short-circuit-protected 24 V DC safe outputs rated to 550 mA each. Verify the exact field interface and approved system configuration before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How much current can each channel switch?
The documented maximum is 550 mA, including thermal and application limits.
Can FC-SDO-0824 drive lamps directly?
Only within the 120 mA / 2.9 W lamp limit after cold-filament inrush is checked.
Why is load capacitance limited?
Excess capacitance can delay switching and disturb diagnostic pulses; the maximum is 1 microfarad.
Which hardware must be matched with FC-SDO-0824?
Verify Resistive and approved DC loads, Maximum 1 microfarad capacitance and the approved Safety Manager hardware list before installation.
Which diagnostics are important for FC-SDO-0824?
Check short-circuit-protected channels, 8 ma watchdog current, command and field-feedback supervision and clear every unexplained channel or system alarm.
Can another construction variant replace FC-SDO-0824?
Only after environmental construction, certifications, hardware revision and project approval have been confirmed.
What commissioning checks are required for FC-SDO-0824?
Perform these product-specific checks: verify field-supply polarity, check fuse and conductor ratings, prove every output and trip state; document the final results.
What information is needed to quote FC-SDO-0824?
Provide the exact module model, hardware revision, connected field circuit, required construction, quantity and destination.