Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports exact-label review, condition evidence, quotation coordination, and shipment checks for KUKA servo packs.

00-198-266

/ 4.9
1001 reviews | Need a Specific Revision?
KUKA 00-198-266 is a KSP 600-3x20 servo pack that converts the KR C4 DC link into three 8 A AC motor-output channels.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 00-198-266
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 00-198-266

  • Manufacturer:
    KUKA
  • Part Number:
    00-198-266
  • Product Family:
    KUKA
  • Product Type:
    KSP 600-3x20 Servo Pack
  • Stock:
    1
  • KUKA article number:
    00198266
  • Module designation:
    KSP 600-3x20
  • Manufacturer type:
    ECMBS3D2224BE531
  • Label hardware version:
    2A
  • DC input:
    2/PE DC 565/675 V, 25 A
  • DC output:
    1 x 2/PE DC 565/675 V, 25 A, 14/17 kW
  • AC outputs:
    3 x 3/PE AC 0–400/480 V, 8 A, 0–500 Hz, 12/14 kW
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Three 8 A Channels DC-Fed Control Low-Current Axes Product Applications

Features:

  • Three 8 A outputs: the equal motor channels define the 3x20 current class.
  • DC-fed architecture: the KSP receives power from the KR C4 intermediate circuit.
  • Axis-group control: three assigned motor paths are handled within one servo pack.
This article performs the servo-amplifier role for a three-axis group rather than the incoming mains-conversion role of a KPP.

Its 8 A outputs form the lowest current class among the supplied KSP 3x20, 3x40, and 3x64 examples.

Module identity, current class, cable order, and axis allocation should travel together through purchase, installation, and commissioning.
Apter Power can review 00-198-266 3x20 identity, three-channel label evidence, condition, and quotation needs.
KUKA 00-198-266 KSP 600-3x20 Servo Pack Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Three equivalent AC outputs serve three assigned motor circuits.
  • Each channel is marked 8 A within a 0–400/480 V range.
  • The output frequency range extends from 0 to 500 Hz with 12/14 kW label points.
  • The KSP receives 565/675 V DC from the cabinet intermediate circuit.
  • A 25 A DC path is carried through the module for the drive-system architecture.
  • Motor control is delivered on the three AC outputs rather than through a direct mains input.
  • The 3x20 designation separates this 8 A class from the higher-current 3x40 and 3x64 packs.
  • Three cable identifiers must remain linked to their original robot-axis assignments.
  • Article 00198266 and hardware version 2A provide receiving-inspection traceability for the photographed unit.
  • Control a documented group of three lower-current manipulator axes in a KR C4 drive cabinet.
  • Replace a failed 3x20 servo-amplifier stage while preserving the original cable and axis order.
  • Maintain an exact-article spare for installed robot controllers using article 00198266.
Description
Three lower-current robot-axis paths are controlled by 00-198-266, the KUKA KSP 600-3x20 article. Rather than accepting the cabinet mains supply, this servo pack draws from the 565/675 V DC intermediate circuit and delivers three regulated AC outputs.

Each motor channel on 00-198-266 is marked at 8 A over the stated 0–400/480 V and 0–500 Hz range. The three equal 3x20 paths make the unit suitable for a defined group of lower-current axes, clearly separating it from 17 A and 20 A KSP variants.

Correct use of 00-198-266 depends on article 00198266, the 3x20 designation, three cable assignments, hardware version evidence, and the approved KR C4 drive layout. Output count alone does not prove suitability if the current class or axis mapping is different.
Alternative Names
00198266 KUKA 198266 KSP600-3X20 article 00198266 KUKA three-channel 8 A servo pack
Technical notes
00-198-266 is the three-channel 8 A KSP configuration; installing a 17 A or 20 A variant by appearance alone would cross the documented current-class boundary. Apply the KUKA isolation and discharge procedure, label all three motor paths, and match article, hardware version, connector map, and axis allocation before restart.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which axis-current class does 00-198-266 provide?
It provides three AC motor outputs rated 8 A each. The 3x20 designation should be matched to the documented KR C4 axis group rather than inferred from housing size.
Does 00-198-266 connect directly to the three-phase mains?
No. Its label shows a 565/675 V DC input, identifying it as a servo pack fed from the cabinet intermediate circuit rather than an incoming power pack.
Why can the three outputs of 00-198-266 not be reconnected in any order?
Each connector belongs to an assigned robot axis. Equal electrical ratings do not make the cable routes interchangeable, so preserve labels and cabinet records during service.
What should be checked when one channel of 00-198-266 reports a fault?
Compare that axis path with the other two while reviewing module status, cable and connector condition, the motor circuit, feedback, safety state, and controller diagnostic messages.
Could 00-198-266 be replaced by a 3x40 servo pack?
Do not assume so. The 3x40 version changes the documented current class, and KUKA cabinet, motor, connector, software, and revision requirements must explicitly support any change.
What is the safe removal sequence for 00-198-266?
Place the robot system in the prescribed safe state, isolate the KR C4 cabinet, observe the manufacturer discharge warning, verify the absence of hazardous energy, and then label each connection.