Reliance Electric GV3000E-AC005-AA-DBU-RFI is a 400 V GV3000/SE drive with IP20 enclosure, braking unit, and RFI filter.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for GV3000E-AC005-AA-DBU-RFI
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for GV3000E-AC005-AA-DBU-RFI

  • Manufacturer:
    Reliance Electric
  • Part Number:
    GV3000E-AC005-AA-DBU-RFI
  • Product Family:
    Reliance Electric
  • Product Type:
    GV3000/SE AC Drive
  • Stock:
    1
  • Manufacturer:
    Reliance Electric
  • Drive family:
    GV3000/SE
  • Part number:
    896.03.31
  • US model:
    55ET4060
  • Input class:
    400 Vac
  • Nominal output current:
    5.5 A V/Hz; 3.8 A vector
  • Motor power:
    2.2 kW V/Hz; 1.5 kW vector
  • Enclosure and options:
    IP20; DBU; RFI filter
  • Weight:
    5.5 kg
  • Estimated shipping dimensions:
    44.2x20x14.3cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Selection Installation Service Checks Applications

Features:

  • Drive role: Controls an AC motor through the selected V/Hz or vector operating mode.
  • Installed options: Keeps the IP20 enclosure, dynamic braking unit and RFI filter tied to the full code.
  • Cross-reference: Connects the European designation with part 896.03.31 and US model 55ET4060.
GV3000E-AC005-AA-DBU-RFI is used where motor control, deceleration energy management and installation filtering are required in the same documented drive build.

The V/Hz and vector ratings represent different operating contexts, so the approved motor data and control mode must remain associated with the parameter set used by the machine.

Keeping the complete GV3000E-AC005-AA-DBU-RFI designation prevents the braking and RFI options from being lost when a shorter GV3000/SE family name appears in maintenance records.

Apter Power supports exact-model document review, quotation, and procurement for the Reliance Electric GV3000E-AC005-AA-DBU-RFI GV3000/SE AC Drive.
Reliance Electric GV3000E-AC005-AA-DBU-RFI GV3000/SE AC Drive Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Electrical rating: confirm 400 Vac system, motor current, and required power mode.
  • Options: retain AA enclosure, DBU braking, and RFI filter.
  • Cross reference: reconcile 896.03.31 and 55ET4060 with the nameplate.
  • Isolation: lock out input and DC-bus sources and verify discharge.
  • Wiring: map line, motor, braking, control, and grounding conductors before removal.
  • Configuration: back up motor data, control mode, I/O, limits, and application parameters.
  • Before replacement: inspect motor insulation, braking circuit, cooling, filter, contactors, and load.
  • Startup: verify voltage, direction, current, acceleration, deceleration, and stop behavior.
  • Acceptance: record exact identifiers, parameters, alarms, and operation through the approved cycle.
  • V/Hz operation: 2.2 kW applications within documented current limits.
  • Vector operation: 1.5 kW applications with approved motor data and tuning.
  • Legacy maintenance: exact-configured GV3000/SE replacement with DBU and RFI options.
Description
In an AC motor system, GV3000E-AC005-AA-DBU-RFI provides the power-conversion and control stage for the approved V/Hz or vector application. Its full designation also preserves the enclosure, dynamic-braking and RFI-filter configuration used by the installation.

When a machine trips during acceleration or deceleration, GV3000E-AC005-AA-DBU-RFI should be evaluated with the selected control mode, motor data, load inertia, braking circuit, line conditions and active fault record. Treating the drive as only a current rating can hide an option or application mismatch.

For replacement, GV3000E-AC005-AA-DBU-RFI should remain cross-referenced with part 896.03.31 and US model 55ET4060. Retaining the complete option code, wiring record and parameter backup reduces the risk of restarting without the intended braking or filtering path.
Alternative Names
GV3000-SE 896.03.31 55ET4060
Technical notes
For GV3000E-AC005-AA-DBU-RFI, isolate all incoming and DC-bus sources, verify discharge, and record motor, control, braking, and filter wiring. Match part 896.03.31, 55ET4060, 400 V ratings, IP20 enclosure, DBU, RFI, control mode, motor data, and parameters; stop if the full suffix or safety circuit differs.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
A maintenance record lists only GV3000-SE. What must be confirmed before ordering GV3000E-AC005-AA-DBU-RFI?
Verify the full designation, part 896.03.31, US model 55ET4060, 400 V class, IP20 enclosure, dynamic braking unit and RFI filter before ordering.
GV3000E-AC005-AA-DBU-RFI trips during deceleration. Which parts of the system should be checked first?
Check the programmed deceleration, motor and load inertia, braking-unit and resistor wiring, DC-bus condition, incoming voltage and the active fault code.
Can an unfiltered GV3000E-AC005-AA-DBU replace GV3000E-AC005-AA-DBU-RFI?
Not automatically. The RFI option belongs to the installed EMC design, so removal requires an approved installation and compliance review.
The motor rating fits the drive, but the previous parameter backup is unavailable. Should commissioning continue?
No. Recover or recreate an approved parameter set from controlled machine data, including motor, mode, I/O, acceleration, deceleration and protection settings, before operation.
What isolation is required before technicians open GV3000E-AC005-AA-DBU-RFI?
Lock out every incoming and DC-bus source, wait the documented discharge interval and verify a safe DC-bus voltage before touching power terminals.
What acceptance evidence should follow replacement of GV3000E-AC005-AA-DBU-RFI?
Record the nameplate cross-references, parameter backup, wiring and grounding checks, motor direction and current, acceleration, deceleration, braking, alarms and final machine cycle.