HCS03.1E-W0150-A-05-NNBV

/ 4.9
1001 reviews | Need a Specific Revision?
Bosch Rexroth HCS03.1E-W0150-A-05-NNBV is a 150 A IndraDrive C compact converter with integrated control-voltage supply and braking transistor.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for HCS03.1E-W0150-A-05-NNBV
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for HCS03.1E-W0150-A-05-NNBV

  • Manufacturer:
    Rexroth
  • Part Number:
    HCS03.1E-W0150-A-05-NNBV
  • Product Family:
    Rexroth
  • Product Type:
    IndraDrive C Compact Converter
  • Stock:
    1
  • Continuous current:
    95 A at 4 kHz nominal data
  • Mains supply:
    3-phase 400 to 500 VAC, +10% / -15%
  • DC bus continuous power:
    34 kW without choke; 56 kW with choke
  • Maximum output:
    54 kW without choke; 89 kW with choke
  • Continuous mains input current:
    106 A
  • Integrated functions:
    24 V control-voltage supply and brake chopper (NNBV)
  • Brake power:
    25.2 kW continuous; 97 kW maximum
  • Protection:
    IP20
  • Dimensions:
    22.5 × 44.0 × 31.5 cm
  • Weight:
    20 kg
  • Tariff Code:
    8503009090
  • Country of origin:
    Germany​
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Braking Design Power Integration Control Restore Application
  • Confirm material R911308421 and the complete NNBV power-section identity
  • Size the axis from the documented 95 A continuous output at 4 kHz, not the 150 A maximum alone
  • Match the assigned mains choke, braking resistor, control section and firmware to the original installation

HCS03.1E-W0150-A-05-NNBV, material R911308421, is an IndraDrive C converter for a three-phase 400–500 VAC supply.

At 4 kHz, its documented output is 150 A maximum and 95 A continuous. DC-bus continuous/maximum power is 34/54 kW without the assigned choke and 56/89 kW with the choke.

The NNBV configuration incorporates the control-voltage supply and brake chopper. Verify the separate control section and firmware, HNL01.1E-0240-N0106-A-500-NNNN mains choke, HLR01.1N-0470-N11R7 braking resistor and machine braking cycle before replacement.

Availability, condition, price, and shipping time for HCS03.1E-W0150-A-05-NNBV are confirmed during quotation.

Bosch Rexroth HCS03.1E-W0150-A-05-NNBV IndraDrive C Compact Converter Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Use only the documented braking-resistor assignment
  • Check regenerated energy, duty cycle and resistor wiring
  • Prove DC-bus voltage remains controlled during deceleration
  • Verify 400 to 500 VAC mains and assigned choke/filter
  • Size shared DC-bus conductors and connected axis load
  • Maintain blower airflow, clearances and cabinet heat removal
  • Match the installed control section and firmware
  • Restore motor, encoder, safety and communication data
  • Validate current limits, stop behavior and fault recovery
  • High-power machine-tool and production axes
  • Printing and paper-processing machinery
  • Packaging, handling and converting systems
Description
HCS03.1E-W0150-A-05-NNBV, material R911308421, is a 150 A IndraDrive C converter with an integrated control-voltage supply and brake chopper.

The separate control section, firmware, braking resistor, mains components and shared DC-bus design must match the original installation.

Before replacement, document the complete type code, control section, firmware, braking circuit, motor and encoder data and all saved axis parameters.
Alternative Names
HCS03.1E-W0150-A-05-NNBV HCS03 1E W0150 A 05 NNBV HCS031EW0150A05NNBV R911308421 Bosch Rexroth HCS03.1E-W0150-A-05-NNBV Rexroth R911308421
Technical notes
HCS03.1E-W0150-A-05-NNBV is material R911308421 with an integrated 24 V control supply and brake chopper. The separate control section, firmware, braking resistor and DC-bus design must all be verified.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can HCS03.1E-W0150-A-05-NNBV feed an axis without a separate HMV supply unit?
Yes, when the machine is engineered around the HCS03 converter architecture. This model combines the mains-fed converter role with the motor inverter; verify the 400–500 V grounded supply, assigned mains choke, DC-bus arrangement and braking duty rather than treating it as an HMS inverter that requires a separate supply unit.
When can HCS03.1E-W0150-A-05-NNBV use its integrated 24 V supply instead of an external control-voltage source?
The NNBV design supports the documented integrated 24 V arrangement only under the specified HCS03 conditions, including the applicable control-section configuration and no motor holding-brake load. If the installed control section, safety option or brake requires more control power, size and connect the external 24 V supply specified for the system.
Which braking resistor is assigned to HCS03.1E-W0150-A-05-NNBV?
Bosch Rexroth assigns the HLR01.1N-0470-N11R7 resistor, with 11.7 Ω resistance, to the W0150 size in the technical-data table. Confirm the machine’s regenerative energy and the drive parameter for the external resistor before ordering or wiring it.
Why does HCS03.1E-W0150-A-05-NNBV deliver less current when the switching frequency is raised?
The official table derates both maximum and continuous output current as switching frequency rises. Maximum current falls from 150 A at 4 kHz to 86 A at 16 kHz, while continuous current falls from 95 A to 37 A, so a quieter or higher-frequency setting can invalidate the original torque and thermal margin.
Can HCS03.1E-W0150-A-05-NNBV be connected directly to an IT or corner-grounded delta mains system?
No. The official mains guidance requires a grounded TN-S, TN-C or TT system for direct 400–500 V operation. An IT system or corner-grounded delta arrangement needs the manufacturer-documented isolation or transformer solution before the converter is connected.
Why can HCS03.1E-W0150-A-05-NNBV overheat while the displayed current is below 95 A?
The 95 A value is the 4 kHz continuous output rating, not the standstill limit. At motor standstill the documented continuous current is 60.9 A at 4 kHz and falls further at higher switching frequencies; also check fan airflow, ambient temperature and motor duty.
Which mains choke should be ordered for HCS03.1E-W0150-A-05-NNBV?
The official assignment table lists HNL01.1E-0240-N0106-A-500-NNNN for the W0150 size. Confirm whether the project uses that standard choke or the documented combined filter/choke arrangement, because the DC-bus power figures differ with and without the assigned choke.