HCS03.1E-W0280-A-05-NNBV

/ 4.9
1001 reviews | Need a Specific Revision?
Bosch Rexroth HCS03.1E-W0280-A-05-NNBV is a 400–500 V feeding converter delivering 165 A continuously at 4 kHz, with a 280 A maximum output.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for HCS03.1E-W0280-A-05-NNBV
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for HCS03.1E-W0280-A-05-NNBV

  • Manufacturer:
    Rexroth
  • Part Number:
    HCS03.1E-W0280-A-05-NNBV
  • Product Family:
    Rexroth
  • Product Type:
    IndraDrive C Compact Converter Power Section
  • Stock:
    1
  • Cooling / protection:
    Internal forced-air cooling; IP20
  • Mains connection:
    3 × AC 400–500 V, +10% / -15%; 50–60 Hz ±2 Hz
  • Rated input current:
    167.0 A
  • Output voltage:
    3 × AC 0–480 V
  • Rated output current:
    165.0 A
  • Maximum output current at 4 kHz:
    280.0 A
  • Continuous output current at 4 kHz:
    165.0 A
  • Continuous output current at 8 kHz:
    98.0 A
  • DC bus rated power with mains choke:
    100.0 kW
  • DC bus rated power without mains choke:
    83.0 kW
  • Mains fuse with assigned choke:
    200 A
  • Control voltage:
    24 V DC ±20%; NNBV also provides control power from the DC bus
  • Ambient temperature:
    0 to 40°C at nominal data; operation with reduced nominal data up to 55°C
  • Derating:
    2% per K above the nominal ambient range
  • Minimum clearance:
    80 mm top; 100 mm bottom
  • Dimensions:
    35.0 × 49.0 × 26.2 cm
  • Weight:
    36.5 kg
  • Tariff Code:
    8503009090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Frequency Selection Mechanical Integration Protection Checks Application
  • Evaluate the 280 A maximum output separately from the 165 A continuous current at 4 kHz
  • Use the verified 98 A continuous-output limit when configured for 8 kHz switching
  • Check the 200 A mains fuse, mounting position and braking-resistor rating as one protection design

HCS03.1E-W0280-A-05-NNBV is a Bosch Rexroth IndraDrive C HCS03 converter with a 280 A maximum output.

It provides 165 A continuously at 4 kHz and 98 A at 8 kHz from a 400–500 V three-phase mains connection.

Before energizing the replacement, verify mains protection, DC-bus and braking connections, cabinet cooling, mounting orientation, control section and commissioned motor data.

Availability, condition, price, and shipping time for HCS03.1E-W0280-A-05-NNBV are confirmed during quotation.

Bosch Rexroth HCS03.1E-W0280-A-05-NNBV Product Resources and Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Use only switching frequencies supported for the W0280 class
  • Recalculate continuous current for the selected frequency and speed
  • Verify control-section and firmware support before downloading parameters
  • Use only the documented G1 or G4 mounting arrangement
  • Maintain unobstructed forced-air paths and service clearances
  • Support heavy power, motor and DC-bus cables without loading terminals
  • Match choke, fuse and conductor size to the W0280 design
  • Verify external brake-resistor resistance and thermal protection
  • Test precharge, DC-bus, fan and loaded thermal behavior
  • Single-axis operation in a Rexroth IndraDrive C system
  • Three-phase asynchronous motor operation
  • Three-phase synchronous motor operation
Description
HCS03.1E-W0280-A-05-NNBV is a Bosch Rexroth IndraDrive C compact converter power section in the IndraDrive C HCS03 family.

Bosch Rexroth HCS03.1E-W0280-A-05-NNBV is an air-cooled IP20 HCS03 feeding compact converter power section for one axis, with a 400–500 V three-phase mains connection, an integrated braking transistor and internal/external 24 V control-power capability. The complete code identifies HCS03 series 03, design 1, feeding supply, internal-air cooling, 280 A maximum-current class, IP20, voltage code 05 and the NNBV option; the control section and any external braking resistor remain separate system items.

Before installation or replacement, confirm the complete HCS03.1E-W0280-A-05-NNBV type plate, separate control section, power and motor connections, cooling arrangement, firmware and commissioned parameters.
Alternative Names
HCS03.1E-W0280-A-05-NNBV HCS03 1E W0280 A 05 NNBV HCS031EW0280A05NNBV Bosch Rexroth HCS03.1E-W0280-A-05-NNBV Rexroth HCS03.1E-W0280-A-05-NNBV
Technical notes
HCS03.1E-W0280-A-05-NNBV is the complete NNBV HCS03 power-section code; the control section and external braking resistor are separate. Match the full type plate, mains and DC-bus design, cooling, motor data and firmware before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What must be verified before reusing an existing motor cable with HCS03.1E-W0280-A-05-NNBV?
Confirm conductor ampacity, temperature rating, length, insulation, shielding, protective-earth path, connector or lug suitability and routing away from feedback wiring. The cable must also satisfy the documented output and switching requirements of the W0280 power section.
What changes if HCS03.1E-W0280-A-05-NNBV is mounted in position G4?
The official cooling table permits G1 or G4 for the larger group, but the cabinet layout must still preserve the documented airflow, clearances, cable forces and accessibility. Confirm the project drawing before changing orientation.
Can any 200 A fuse be used to protect HCS03.1E-W0280-A-05-NNBV?
No. The fuse must match the Bosch Rexroth-specified type, voltage rating, interrupting capacity and semiconductor-protection characteristics, and it must coordinate with the mains choke, conductors and available short-circuit current.
Why can motor torque fall after HCS03.1E-W0280-A-05-NNBV is changed from 4 kHz to 8 kHz switching?
The permitted continuous output current is lower at 8 kHz, so the converter may reach its thermal or current limit earlier under load. Recheck the motor duty, torque limits, acceleration profile, cabinet cooling and configured switching frequency.
Can HCS03.1E-W0280-A-05-NNBV replace W0350 without changing the cabinet?
The housing envelope is shared, but the current ratings, mains protection, choke and DC-bus power differ. A mechanical fit does not establish electrical or parameter compatibility.
Which system identities must accompany HCS03.1E-W0280-A-05-NNBV in a replacement order?
Provide the complete power-section type plate, control-section type, firmware, motor type, assigned choke and fuse, braking resistor, DC-bus topology and cabinet cooling arrangement.
How should HCS03.1E-W0280-A-05-NNBV be commissioned?
Validate mains and precharge, 24 V control supply, DC-bus sharing, fan operation and configured switching frequency; then perform staged motor, brake and load tests while monitoring current and temperature.