6ES7675-1DA20-6AX0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6ES7675-1DA20-6AX0 is a fan-free SIMATIC IPC427C client bundle with WinCC V7.0 SP2 Update 1, a Celeron M processor, 1 GB RAM, and a 4 GB CompactFlash card.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7675-1DA20-6AX0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7675-1DA20-6AX0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7675-1DA20-6AX0
  • Product Family:
    SIMATIC PC
  • Product Type:
    SIMATIC IPC427C WinCC V7.0 Client Bundle
  • Stock:
    1
  • Bundle Role:
    WinCC V7.0 client configuration
  • Processor:
    Intel Celeron M, 1.2 GHz
  • Main Memory:
    1 GB DDR3 SDRAM
  • Mass Storage:
    4 GB CompactFlash card
  • Runtime License:
    128 process tags
  • Operating System:
    Windows Embedded Standard 2009
  • Visualization Software:
    SIMATIC WinCC V7.0 SP2 including Update 1 Runtime
  • Ethernet Interfaces:
    2 x 10/100 Mbit/s RJ45
  • USB Interfaces:
    4 x USB 2.0, 500 mA per port
  • Serial Interface:
    1 x COM, RS232
  • Video Interface:
    1 x DVI-I
  • Rated Supply:
    24 V DC
  • Supply Range:
    19.2 to 28.8 V DC
  • Cooling:
    Fan-free
  • Protection Rating:
    IP20
  • Mounting:
    DIN rail, wall, or upright front mounting
  • Operating Temperature:
    0 to 50 °C at maximum configuration
  • Relative Humidity:
    Up to 95% with CompactFlash storage
  • Weight:
    4.409 lbs (2 kg)
  • Estimated shipping dimensions:
    26.2x13.4x4.7cm
  • Tariff Code:
    8471504090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Client Bundle Hardware Interfaces Software Setup

Features:

  • A fan-free IPC427C runs the preinstalled WinCC V7.0 SP2 Update 1 client environment.
  • A Celeron M processor, 1 GB DDR3 memory, and 4 GB CompactFlash form the documented client configuration.
  • Two Ethernet ports, four USB 2.0 ports, one RS232 COM port, and 24 V DC supply serve the deployed station.
Siemens 6ES7675-1DA20-6AX0 combines embedded IPC hardware and licensed WinCC client runtime in one orderable bundle.

CompactFlash storage on 6ES7675-1DA20-6AX0 carries the embedded operating system, runtime installation, and transferred project.

Network and local interfaces on 6ES7675-1DA20-6AX0 separate plant communication from service and peripheral connections.

The Siemens 6ES7675-1DA20-6AX0 SIMATIC IPC427C WinCC V7.0 Client Bundle may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7675-1DA20-6AX0 SIMATIC IPC427C WinCC V7.0 Client Bundle Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Hardware and Runtime Scope

  • IPC hardware: The fan-free IPC427C supplies the processing, interfaces, and 24 V DC power input.
  • Client software: WinCC V7.0 SP2 including Update 1 Runtime is preinstalled for the client role.
  • License scope: The documented runtime license covers 128 process tags.
  • Storage role: The 4 GB CompactFlash card carries the embedded system, runtime, and project files.

Processor, Memory and Cooling

  • Processor path: The 1.2 GHz Celeron M executes the embedded operating system and WinCC client tasks.
  • Working memory: One gigabyte of DDR3 RAM supports the running client and communications processes.
  • Fan-free design: Heat leaves the compact enclosure without a rotating cooling fan.
  • Mounting options: The IPC427C can be installed on a DIN rail, wall, or upright front position within the documented limits.

Network and Local Connections

  • Ethernet links: Two RJ45 connections carry configured plant-network and client/server traffic.
  • USB ports: Four USB 2.0 ports connect supported local service or peripheral devices.
  • Serial channel: The RS232 COM port provides one documented serial connection path.
  • Display output: The DVI-I interface connects the selected local monitor or flat-panel display.

Project Transfer and Recovery

  • Client project: The engineering project must identify this station as the intended WinCC client.
  • Network settings: Server names, addresses, and Ethernet paths must match the deployed client/server design.
  • Write filter: Flash protection is enabled only after required applications and project files are transferred.
  • Recovery copy: A verified CompactFlash backup preserves the licensed runtime environment and station configuration.
Description
Siemens 6ES7675-1DA20-6AX0 is a SIMATIC IPC427C industrial computer bundle configured as a WinCC V7.0 client. Its fan-free hardware, embedded operating system, and preinstalled runtime software form one ready-to-configure visualization station.

Processing in 6ES7675-1DA20-6AX0 is handled by a 1.2 GHz Intel Celeron M processor with 1 GB DDR3 memory. A 4 GB CompactFlash card holds Windows Embedded Standard 2009, WinCC Runtime, and the client project without relying on a rotating hard disk.

Two Ethernet connections on 6ES7675-1DA20-6AX0 link the WinCC client to the configured industrial network, while four USB 2.0 ports and one RS232 COM port serve local peripherals and serial equipment. The 24 V DC input supplies the same compact unit through its line-side on/off switch.

Commissioning 6ES7675-1DA20-6AX0 requires the 128-process-tag runtime license, network settings, and WinCC client project to agree. After transfer, the CompactFlash installation should be backed up and its write filter set according to the deployed application.
Alternative Names
6ES76751DA206AX0 6ES7675 1DA20 6AX0 6ES 7675 1DA20 6AX0 Siemens 6ES7675-1DA20-6AX0 6ES7675-1DA20-6AX0 IPC427C 6ES7675-1DA20-6AX0 WinCC Client 6ES767S-1DA2O-6AXO 6ES7675-IDA20-6AX0
Technical notes
The WinCC project, 128-tag license, network settings, and CompactFlash backup must remain aligned when commissioning Siemens 6ES7675-1DA20-6AX0.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can 6ES7675-1DA20-6AX0 start Windows but fail to open its WinCC client project?
Check the 6ES7675-1DA20-6AX0 project assignment, server name, Ethernet addressing, runtime license, startup entry, and CompactFlash file status.
What should be backed up before replacing 6ES7675-1DA20-6AX0?
Preserve the 6ES7675-1DA20-6AX0 CompactFlash image, WinCC client project, 128-tag license record, network settings, and connected-interface map.
Why is a USB device not detected reliably by 6ES7675-1DA20-6AX0?
Verify the 6ES7675-1DA20-6AX0 USB port, 500 mA load limit, cable, device driver, embedded Windows support, and write-filter state.
Which network checks matter when 6ES7675-1DA20-6AX0 cannot reach the WinCC server?
Compare the 6ES7675-1DA20-6AX0 IP settings, link LEDs, cable path, switch port, server name resolution, firewall rules, and WinCC connection configuration.
Why should the write filter on 6ES7675-1DA20-6AX0 be configured after project transfer?
Enabling flash protection too early can prevent 6ES7675-1DA20-6AX0 project, license, or network changes from remaining after a restart.
What must match before restoring a CompactFlash image to 6ES7675-1DA20-6AX0?
Confirm the image belongs to 6ES7675-1DA20-6AX0 and matches its WinCC version, client role, runtime license, drivers, and interface configuration.