Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    For 6GK5992-1AL00-8AA0, Apter Power offers quotations, product manuals, and SCALANCE optical-interface matching.

6GK5992-1AL00-8AA0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6GK5992-1AL00-8AA0 is an SFP992-1 optical transceiver with one LC multimode 1000 Mbit/s port for fiber links up to 750 m.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6GK5992-1AL00-8AA0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GK5992-1AL00-8AA0

  • Manufacturer:
    Siemens
  • Part Number:
    6GK5992-1AL00-8AA0
  • Product Family:
    Siemens SCALANCE
  • Product Type:
    SCALANCE SFP992-1 Gigabit Multimode Optical Transceiver
  • Stock:
    1
  • Optical Medium:
    Multimode glass fiber
  • Optical Interface:
    LC duplex
  • Data Rate:
    1000 Mbit/s
  • Maximum Link Length:
    750 m
  • Optical Wavelength:
    850 nm
  • Transmitter Power:
    -9.5 to -2.5 dBm
  • Receiver Sensitivity:
    Minimum -17 dBm
  • Receiver Maximum Input:
    -3 dBm
  • Duplex Mode:
    Full duplex
  • Installation:
    Latched insertion into a compatible SFP slot
  • Degree of Protection:
    IP20
  • Operating Temperature:
    -40 to +85 °C
  • Storage and Transport Temperature:
    -40 to +85 °C
  • Relative Humidity:
    Maximum 95%, no condensation
  • Weight:
    0.075 lbs (0.034 kg)
  • Estimated shipping dimensions:
    1.4×5.7×0.9cm
  • Tariff Code:
    85176200
  • Country of origin:
    Malaysia
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Optical Budget Fiber Pair Slot Installation Environmental Check

Features:

  • One LC duplex port carries 1000 Mbit/s multimode optical traffic.
  • The 850 nm link is specified for cable runs up to 750 m.
  • A latched SFP body receives power and data from the compatible host slot.
Siemens 6GK5992-1AL00-8AA0 changes a supported SCALANCE slot from its internal electrical interface to a full-duplex fiber path.

The transmitter and receiver limits define the usable optical budget together with cable attenuation and connector losses.

Because the module has no independent supply or enclosure, slot compatibility and host temperature remain part of the installation check.

The Siemens 6GK5992-1AL00-8AA0 SCALANCE SFP992-1 Gigabit Multimode Optical Transceiver may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5992-1AL00-8AA0 SFP992-1 Optical Transceiver Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Transmitter-to-Receiver Limits

  • Launch range: Optical transmit power is specified from -9.5 to -2.5 dBm.
  • Sensitivity: The receiver detects an input down to -17 dBm.
  • Upper boundary: Received power must not exceed the -3 dBm maximum input.
  • Link check: Fiber and connector losses must leave the received level inside that window.

LC Multimode Signal Path

  • Connector: A duplex LC interface separates transmit and receive fibers.
  • Medium: The module is assigned to multimode glass fiber rather than single-mode cable.
  • Wavelength: Both optical directions use the 850 nm class.
  • Distance: The documented maximum cable run is 750 m.

SFP and Host Relationship

  • Insertion: The transceiver slides into a compatible SCALANCE SFP receptacle.
  • Retention: The latch secures the module after full seating.
  • Host services: The switch or media module supplies operating power and the Gigabit electrical interface.
  • Removal boundary: Release the latch before withdrawing the module; do not pull on the fiber cable.

Optical Operation Across Temperature

  • Operating span: The transceiver is specified from -40 to +85 °C.
  • Storage span: The same -40 to +85 °C boundary applies during storage and transport.
  • Humidity: Relative humidity may reach 95% only when condensation is absent.
  • Enclosure level: The IP20 rating requires protection appropriate to the complete installed host.
Description
Siemens 6GK5992-1AL00-8AA0 is the SFP992-1 plug-in transceiver used to add one optical Gigabit Ethernet interface to a compatible SCALANCE SFP slot. It terminates a duplex LC multimode fiber pair and carries 1000 Mbit/s traffic in full-duplex operation.

The optical channel of 6GK5992-1AL00-8AA0 operates at 850 nm and is specified for multimode glass-fiber links up to 750 m. Transmit power extends from -9.5 to -2.5 dBm, while the receive side combines -17 dBm minimum sensitivity with a -3 dBm maximum input boundary.

Insertion places 6GK5992-1AL00-8AA0 inside the host switch or media-module slot, and its latch retains the transceiver while the LC connector remains accessible for the fiber pair. The host slot supplies the module and presents its Gigabit electrical interface, so the SFP does not operate as a stand-alone converter.

The IP20 body of 6GK5992-1AL00-8AA0 is specified from -40 to +85 °C for operation, storage and transport, with relative humidity up to 95% without condensation. Link commissioning therefore requires both the optical power limits and the environmental boundary to remain valid at the selected SCALANCE location.
Alternative Names
Siemens 6GK5992-1AL00-8AA0 SFP992-1 SCALANCE SFP992-1 6GK5992-1AL00-8AA0 6GK59921AL008AA0 Gigabit Transceiver 6GK 5992-1AL00-8AA0 LC SFP Siemens Multimode SFP 6GK5992-1AL00-8AA0 6GK5992-1AL00-8AA0 850 nm Optical Module SCALANCE 750 m SFP 6GK5992-1AL00-8AA0 Siemens SFP992-1 Order 6GK5992-1AL00-8AA0
Technical notes
Siemens 6GK5992-1AL00-8AA0 requires a compatible SCALANCE SFP slot and multimode LC fiber; link length alone does not replace the transmitter and receiver power-budget checks.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Will 6GK5992-1AL00-8AA0 work with single-mode fiber?
No. 6GK5992-1AL00-8AA0 is specified for multimode glass fiber at 850 nm and uses a duplex LC interface.
Why can a 6GK5992-1AL00-8AA0 link fail even when the cable is shorter than 750 m?
For 6GK5992-1AL00-8AA0, distance is only one limit; connector loss, fiber attenuation and received power must still remain between the -17 dBm sensitivity and -3 dBm maximum input.
Can 6GK5992-1AL00-8AA0 operate without a SCALANCE switch or media module?
No. 6GK5992-1AL00-8AA0 receives power and its Gigabit electrical interface from a compatible SFP host slot, so it is not a stand-alone media converter.
Which connector is required for 6GK5992-1AL00-8AA0?
Use a duplex LC multimode fiber connection with 6GK5992-1AL00-8AA0, keeping the transmit and receive strands in the correct orientation.
What should be checked when 6GK5992-1AL00-8AA0 is not detected by the host?
For 6GK5992-1AL00-8AA0, verify that the SCALANCE slot supports SFP992-1, then reseat the module until its latch is fully engaged before checking the optical side.
Can 6GK5992-1AL00-8AA0 remain installed at -40 °C?
Yes. 6GK5992-1AL00-8AA0 is specified for operation from -40 to +85 °C, provided the compatible host and complete enclosure also meet the site conditions.